메뉴 건너뛰기




Volumn 29, Issue 5, 2009, Pages 1190-1194

Diminished Visibility of Cerebral Venous Vasculature in Multiple Sclerosis by Susceptibility- Weighted Imaging at 3.0 Tesla

Author keywords

Magnetic resonance; Multiple sclerosis; Oxygenation; Susceptibility weighted imaging; Venography

Indexed keywords

ADULT; ARTICLE; BRAIN PERFUSION; BRAIN VEIN; CENTRAL NERVOUS SYSTEM DISEASE; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC IMAGING; DISEASE SEVERITY; EXPANDED DISABILITY STATUS SCALE; FEMALE; HUMAN; IMAGING SYSTEM; MALE; MULTIPLE SCLEROSIS; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; OXYGEN SATURATION; PHLEBOGRAPHY; PRIORITY JOURNAL; SUSCEPTIBILITY WEIGHTED IMAGING; METHODOLOGY; MIDDLE AGED; PATHOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 66149097017     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21758     Document Type: Article
Times cited : (117)

References (19)
  • 1
    • 0035866558 scopus 로고    scopus 로고
    • Multiple sclerosis: A white matter disease with associated gray matter damage
    • Filippi M. Multiple sclerosis: a white matter disease with associated gray matter damage. J Neurol Sci 2001;185:3-4.
    • (2001) J Neurol Sci , vol.185 , pp. 3-4
    • Filippi, M.1
  • 4
    • 0020686503 scopus 로고
    • New diagnostic criteria for multiple sclerosis: Guidelines for research protocols
    • Poser CM, Paty DW, Scheinberg L, et al. New diagnostic criteria for multiple sclerosis: guidelines for research protocols. Ann Neurol 1983;13:227-231.
    • (1983) Ann Neurol , vol.13 , pp. 227-231
    • Poser, C.M.1    Paty, D.W.2    Scheinberg, L.3
  • 5
    • 0033201370 scopus 로고    scopus 로고
    • An adaptive segmentation algorithm for timeof-flight MRA data
    • Wilson DL, Noble JA. An adaptive segmentation algorithm for timeof-flight MRA data. IEEE Trans Med Imaging 1999;18:938-945.
    • (1999) IEEE Trans Med Imaging , vol.18 , pp. 938-945
    • Wilson, D.L.1    Noble, J.A.2
  • 6
    • 51449113619 scopus 로고    scopus 로고
    • Complex threshold method for identifying pixels that contain predominantly noise in magnetic resonance images
    • Pandian DS, Ciulla C, Haacke EM, Jiang J, Ayaz M. Complex threshold method for identifying pixels that contain predominantly noise in magnetic resonance images. J Magn Reson Imaging 2008; 28:727-735.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 727-735
    • Pandian, D.S.1    Ciulla, C.2    Haacke, E.M.3    Jiang, J.4    Ayaz, M.5
  • 7
    • 0034325176 scopus 로고    scopus 로고
    • A Measure of compactness for 3D shapes
    • Bribiesca E. A Measure of compactness for 3D shapes. Computers Math Appl 2000:1275-1284.
    • (2000) Computers Math Appl , pp. 1275-1284
    • Bribiesca, E.1
  • 9
    • 0034447740 scopus 로고    scopus 로고
    • MR image analysis in multiple sclerosis
    • x
    • Nyul LG, Udupa JK. MR image analysis in multiple sclerosis. Neuroimaging Clin N Am 2000;10:799-816, x.
    • (2000) Neuroimaging Clin N Am , vol.10 , pp. 799-816
    • Nyul, L.G.1    Udupa, J.K.2
  • 10
    • 0034767131 scopus 로고    scopus 로고
    • Multiprotocol MR image segmentation in multiple sclerosis: Experience with over 1, 000 studies
    • Udupa JK, Nyul LG, Ge Y, Grossman RI. Multiprotocol MR image segmentation in multiple sclerosis: experience with over 1, 000 studies. Acad Radiol 2001;8:1116-1126.
    • (2001) Acad Radiol , vol.8 , pp. 1116-1126
    • Udupa, J.K.1    Nyul, L.G.2    Ge, Y.3    Grossman, R.I.4
  • 11
    • 21244469440 scopus 로고    scopus 로고
    • Nonnvasive assessment of vascular architecture and function during modulated blood oxygenation using susceptibility weighted magnetic resonance imaging
    • Rauscher A, Sedlacik J, Barth M, Haacke EM, Reichenbach JR. Nonnvasive assessment of vascular architecture and function during modulated blood oxygenation using susceptibility weighted magnetic resonance imaging. Magn Reson Med 2005;54:87-95.
    • (2005) Magn Reson Med , vol.54 , pp. 87-95
    • Rauscher, A.1    Sedlacik, J.2    Barth, M.3    Haacke, E.M.4    Reichenbach, J.R.5
  • 12
    • 66249124810 scopus 로고    scopus 로고
    • Susceptibility weighted imaging (SWI) of cerebral blood oxygenation during voluntary hyperventilation and apnea
    • Berlin, Germany, abstract 2300
    • Ge Y, Haacke E, Grossman RI. Susceptibility weighted imaging (SWI) of cerebral blood oxygenation during voluntary hyperventilation and apnea. In: Proceedings of the 15th Annual Meeting of ISMRM, Berlin, Germany, 2007. (abstract 2300).
    • (2007) Proceedings of the 15th Annual Meeting of ISMRM
    • Ge, Y.1    Haacke, E.2    Grossman, R.I.3
  • 13
    • 0031717172 scopus 로고    scopus 로고
    • Highresolution fluorodeoxyglucose positron emission tomography shows both global and regional cerebral hypometabolism in multiple sclerosis
    • Bakshi R, Miletich RS, Kinkel PR, Emmet ML, Kinkel WR. Highresolution fluorodeoxyglucose positron emission tomography shows both global and regional cerebral hypometabolism in multiple sclerosis. J Neuroimaging 1998;8:228-234.
    • (1998) J Neuroimaging , vol.8 , pp. 228-234
    • Bakshi, R.1    Miletich, R.S.2    Kinkel, P.R.3    Emmet, M.L.4    Kinkel, W.R.5
  • 14
    • 0034620499 scopus 로고    scopus 로고
    • Cortical cerebral metabolism correlates with MRI lesion load and cognitive dysfunction in MS
    • Blinkenberg M, Rune K, Jensen CV, et al. Cortical cerebral metabolism correlates with MRI lesion load and cognitive dysfunction in MS. Neurology 2000;54:558-564.
    • (2000) Neurology , vol.54 , pp. 558-564
    • Blinkenberg, M.1    Rune, K.2    Jensen, C.V.3
  • 15
    • 0028330910 scopus 로고
    • Immunohistochemical study of vascular injury in acute multiple sclerosis
    • Wakefield AJ, More LJ, Difford J, McLaughlin JE. Immunohistochemical study of vascular injury in acute multiple sclerosis. J Clin Pathol 1994;47:129-133.
    • (1994) J Clin Pathol , vol.47 , pp. 129-133
    • Wakefield, A.J.1    More, L.J.2    Difford, J.3    McLaughlin, J.E.4
  • 16
    • 2442679165 scopus 로고    scopus 로고
    • Microvascular abnormality in relapsing-remitting multiple sclerosis: Perfusion MR imaging findings in normal-appearing white matter
    • Law M, Saindane AM, Ge Y, et al. Microvascular abnormality in relapsing-remitting multiple sclerosis: perfusion MR imaging findings in normal-appearing white matter. Radiology 2004;231:645-652.
    • (2004) Radiology , vol.231 , pp. 645-652
    • Law, M.1    Saindane, A.M.2    Ge, Y.3
  • 17
    • 49049091751 scopus 로고    scopus 로고
    • Quantitative evaluation of oxygenation in venous vessels using T2-relaxation-under-spin-tagging MRI
    • Lu H, Ge Y. Quantitative evaluation of oxygenation in venous vessels using T2-relaxation-under-spin-tagging MRI. Magn Reson Med 2008;60:357-363.
    • (2008) Magn Reson Med , vol.60 , pp. 357-363
    • Lu, H.1    Ge, Y.2
  • 18
    • 49049089731 scopus 로고    scopus 로고
    • Baseline blood oxygenation modulates response amplitude: Physiologic basis for intersubject variations in functional MRI signals
    • Lu H, Zhao C, Ge Y, Lewis-Amezcua K. Baseline blood oxygenation modulates response amplitude: physiologic basis for intersubject variations in functional MRI signals. Magn Reson Med 2008;60: 364-372.
    • (2008) Magn Reson Med , vol.60 , pp. 364-372
    • Lu, H.1    Zhao, C.2    Ge, Y.3    Lewis-Amezcua, K.4
  • 19
    • 0034242245 scopus 로고    scopus 로고
    • Validity and reliability of the SjO2 catheter in neurologically impaired patients: A critical review of the literature
    • Clay HD. Validity and reliability of the SjO2 catheter in neurologically impaired patients: a critical review of the literature. J Neurosci Nurs 2000;32:194-203.
    • (2000) J Neurosci Nurs , vol.32 , pp. 194-203
    • Clay, H.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.