메뉴 건너뛰기




Volumn , Issue , 2008, Pages 158-161

Wireless biliary stent system with wishbone-array resonant magnetoelastic (Warm) sensor and conformal magnetic layer

Author keywords

[No Author keywords available]

Indexed keywords

ACTUATORS; DUCTS; MICROSYSTEMS; NATURAL FREQUENCIES; PERMANENT MAGNETS; STENTS;

EID: 65949108535     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.31438/trf.hh2008.43     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 1
    • 36048942824 scopus 로고    scopus 로고
    • Plastic Biliary Stent Occlusion: Factors Involved and Possible Preventive Approaches
    • G. Donnelli, et al., “Plastic Biliary Stent Occlusion: Factors Involved and Possible Preventive Approaches,” Clinical Medicine & Research, Vol. 5, No. 1, 2007, pp. 53-60.
    • (2007) Clinical Medicine & Research , vol.5 , Issue.1 , pp. 53-60
    • Donnelli, G.1
  • 2
    • 50049099602 scopus 로고    scopus 로고
    • Photochemically Patterned Biliary Stents with Integrated Permanent Magnets and Deformable Assembly Features for Wireless Magnetoelastic Tissue Growth Sensing
    • S. R. Green, et al., “Photochemically Patterned Biliary Stents with Integrated Permanent Magnets and Deformable Assembly Features for Wireless Magnetoelastic Tissue Growth Sensing,” Transducers 2007. June 2007, pp. 213-217.
    • (2007) Transducers 2007 , pp. 213-217
    • Green, S.R.1
  • 3
    • 0035000050 scopus 로고    scopus 로고
    • Magnetoelastic Microsensors for Environmental Monitoring
    • C. Grimes, et al., “Magnetoelastic Microsensors for Environmental Monitoring,” IEEE Transducers 2001, pp. 278-281.
    • (2001) IEEE Transducers , pp. 278-281
    • Grimes, C.1
  • 4
    • 0035306124 scopus 로고    scopus 로고
    • A Wireless Micro-sensor for Simultaneous Measurement of pH, Temperature, and Pressure
    • M. Jain, et al., “A Wireless Micro-sensor for Simultaneous Measurement of pH, Temperature, and Pressure,” Smart Mat. and Struc., Vol. 10, 2001, pp. 347-353.
    • (2001) Smart Mat. and Struc , vol.10 , pp. 347-353
    • Jain, M.1
  • 5
    • 0347107292 scopus 로고    scopus 로고
    • Simultaneous measurement of liquid density and viscosity using remote query magnetoelastic sensors
    • C. Grimes, et al., “Simultaneous measurement of liquid density and viscosity using remote query magnetoelastic sensors”, Rev. Sci. Inst., Vol. 7, Issue 10, 2000, pp. 3822-3824.
    • (2000) Rev. Sci. Inst. , vol.7 , Issue.10 , pp. 3822-3824
    • Grimes, C.1
  • 6
    • 51249168164 scopus 로고
    • Embrittlement of Amorphous Fe40Ni38Mo4B18 Alloy by Electrolytic Hydrogen
    • J.-J. Lin, et al., “Embrittlement of Amorphous Fe40Ni38Mo4B18 Alloy by Electrolytic Hydrogen,” Met. and Mat. Trans. A, Vol. 26, No. 1, 1995, pp. 197-201.
    • (1995) Met. and Mat. Trans. A , vol.26 , Issue.1 , pp. 197-201
    • Lin, J.-J.1
  • 7
    • 85061911343 scopus 로고    scopus 로고
    • www.matweb.com
  • 8
    • 52149113998 scopus 로고    scopus 로고
    • Magnetoelastic Wireless Sensing of Tissue Growth for Self-Expanding Biliary Stents
    • M.T. Richardson, et al., “Magnetoelastic Wireless Sensing of Tissue Growth for Self-Expanding Biliary Stents,” IEEE MEMS 2007, pp. 469-472.
    • (2007) IEEE MEMS , pp. 469-472
    • Richardson, M.T.1
  • 9
    • 84863523492 scopus 로고    scopus 로고
    • FEM Implementations of Magnetostrictive-Based Applications
    • J. Benatar, “FEM Implementations of Magnetostrictive-Based Applications”, MS thesis, University of Maryland, 2005.
    • (2005) MS Thesis, University of Maryland
    • Benatar, J.1
  • 10
    • 0031342760 scopus 로고    scopus 로고
    • Magnetic and Mechanical Properties of Micromachined Strontium Ferrite/Polyimide Composites
    • L. Lagorce, et al, “Magnetic and Mechanical Properties of Micromachined Strontium Ferrite/Polyimide Composites,” JMEMS, Vol. 6, No. 4, 1997, pp. 307-312.
    • (1997) JMEMS , vol.6 , Issue.4 , pp. 307-312
    • Lagorce, L.1
  • 11
    • 0036009001 scopus 로고    scopus 로고
    • Role of Bile Mucin in Bacterial Adherence to Biliary Stents
    • Jan
    • H. Zhang et al., “Role of Bile Mucin in Bacterial Adherence to Biliary Stents,” J. Lab Clin Med, 139(1), pp. 28-34, Jan 2002.
    • (2002) J. Lab Clin Med , vol.139 , Issue.1 , pp. 28-34
    • Zhang, H.1
  • 12
    • 33750347282 scopus 로고    scopus 로고
    • Mechanical Properties and Failure of Streptococcus mutans Biofilms, Studied Using a Microindentation Device
    • A.W. Cense, et al., “Mechanical Properties and Failure of Streptococcus mutans Biofilms, Studied Using a Microindentation Device,” J. Microbiological Methods, Vol. 67, 2006, pp. 463-472.
    • (2006) J. Microbiological Methods , vol.67 , pp. 463-472
    • Cense, A.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.