메뉴 건너뛰기




Volumn 101, Issue 6, 2009, Pages 372-381

Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: An in vitro study

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; AUDIOVISUAL EQUIPMENT; COMPARATIVE STUDY; COMPUTER AIDED DESIGN; COMPUTER ASSISTED SURGERY; COMPUTER INTERFACE; DENTAL CARE; EDENTULOUSNESS; EQUIPMENT DESIGN; EVALUATION; HUMAN; MANDIBLE; METHODOLOGY; RADIOGRAPHY; STATISTICS; TOOTH IMPLANTATION; TOOTH OCCLUSION; TORQUE;

EID: 65749095791     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-3913(09)60080-9     Document Type: Article
Times cited : (65)

References (35)
  • 1
    • 0029349223 scopus 로고
    • Restoration-driven implant placement with restoration-generated site development
    • 796, 804.
    • Garber D.A., and Belser U.C. Restoration-driven implant placement with restoration-generated site development. Compend Contin Educ Dent 16 (1995) 798-802 796, 804.
    • (1995) Compend Contin Educ Dent , vol.16 , pp. 798-802
    • Garber, D.A.1    Belser, U.C.2
  • 2
    • 0027344628 scopus 로고
    • Surgical implant stent: a design modification and simplified fabrication technique
    • Neidlinger J., Lilien B.A., and Kalant Sr. D.C. Surgical implant stent: a design modification and simplified fabrication technique. J Prosthet Dent 69 (1993) 70-72
    • (1993) J Prosthet Dent , vol.69 , pp. 70-72
    • Neidlinger, J.1    Lilien, B.A.2    Kalant Sr., D.C.3
  • 4
    • 0026813267 scopus 로고
    • Fabrication of an implant surgical stent for the edentulous mandible
    • Tarlow J.L. Fabrication of an implant surgical stent for the edentulous mandible. J Prosthet Dent 67 (1992) 217-218
    • (1992) J Prosthet Dent , vol.67 , pp. 217-218
    • Tarlow, J.L.1
  • 5
    • 0034132386 scopus 로고    scopus 로고
    • Fabrication of a radiographic and surgical stent for implants with a vacuum former
    • Ku Y.C., and Shen Y.F. Fabrication of a radiographic and surgical stent for implants with a vacuum former. J Prosthet Dent 83 (2000) 252-253
    • (2000) J Prosthet Dent , vol.83 , pp. 252-253
    • Ku, Y.C.1    Shen, Y.F.2
  • 6
    • 0030147224 scopus 로고    scopus 로고
    • Surgical guide fabrication for an angled implant
    • Dixon D.L., and Breeding L.C. Surgical guide fabrication for an angled implant. J Prosthet Dent 75 (1996) 562-565
    • (1996) J Prosthet Dent , vol.75 , pp. 562-565
    • Dixon, D.L.1    Breeding, L.C.2
  • 7
    • 0023991824 scopus 로고
    • Optimum placement of osseointegrated implants
    • Engelman M.J., Sorensen J.A., and Moy P. Optimum placement of osseointegrated implants. J Prosthet Dent 59 (1988) 467-473
    • (1988) J Prosthet Dent , vol.59 , pp. 467-473
    • Engelman, M.J.1    Sorensen, J.A.2    Moy, P.3
  • 8
    • 0028438173 scopus 로고
    • A diagnostic stent for endosseous implants to improve conventional tomographic radiographs
    • Lee S.Y., and Morgano S.M. A diagnostic stent for endosseous implants to improve conventional tomographic radiographs. J Prosthet Dent 71 (1994) 482-485
    • (1994) J Prosthet Dent , vol.71 , pp. 482-485
    • Lee, S.Y.1    Morgano, S.M.2
  • 9
    • 0026168212 scopus 로고
    • The use and fabrication of a self-retaining surgical guide for controlled implant placement: a technical note
    • Parel S.M., and Funk J.J. The use and fabrication of a self-retaining surgical guide for controlled implant placement: a technical note. Int J Oral Maxillofac Implants 6 (1991) 207-210
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 207-210
    • Parel, S.M.1    Funk, J.J.2
  • 10
    • 0036482540 scopus 로고    scopus 로고
    • A surgical guide for accurate mesiodistal paralleling of implants in the posterior edentulous mandible
    • Akça K., Iplikçioglu H., and Cehreli M.C. A surgical guide for accurate mesiodistal paralleling of implants in the posterior edentulous mandible. J Prosthet Dent 87 (2002) 233-235
    • (2002) J Prosthet Dent , vol.87 , pp. 233-235
    • Akça, K.1    Iplikçioglu, H.2    Cehreli, M.C.3
  • 11
    • 0031607958 scopus 로고    scopus 로고
    • Profile surgical template: a systematic approach to precise implant placement. A technical note
    • Sicilia A., Noguerol B., Cobo J., and Zabalegui I. Profile surgical template: a systematic approach to precise implant placement. A technical note. Int J Oral Maxillofac Implants 13 (1998) 109-114
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 109-114
    • Sicilia, A.1    Noguerol, B.2    Cobo, J.3    Zabalegui, I.4
  • 12
    • 14844325832 scopus 로고    scopus 로고
    • Implant surgical guide fabrication for partially edentulous patients
    • Shotwell J.L., Billy E.J., Wang H.L., and Oh T.J. Implant surgical guide fabrication for partially edentulous patients. J Prosthet Dent 93 (2005) 294-297
    • (2005) J Prosthet Dent , vol.93 , pp. 294-297
    • Shotwell, J.L.1    Billy, E.J.2    Wang, H.L.3    Oh, T.J.4
  • 13
    • 0035227742 scopus 로고    scopus 로고
    • Simplified radiographic-surgical template for placement of multiple, parallel implants
    • Solow R.A. Simplified radiographic-surgical template for placement of multiple, parallel implants. J Prosthet Dent 85 (2001) 26-29
    • (2001) J Prosthet Dent , vol.85 , pp. 26-29
    • Solow, R.A.1
  • 14
    • 0024103243 scopus 로고
    • Template for positioning and angulation of intraosseous implants
    • Burns D.R., Crabtree D.G., and Bell D.H. Template for positioning and angulation of intraosseous implants. J Prosthet Dent 60 (1988) 479-483
    • (1988) J Prosthet Dent , vol.60 , pp. 479-483
    • Burns, D.R.1    Crabtree, D.G.2    Bell, D.H.3
  • 15
    • 0034132551 scopus 로고    scopus 로고
    • Surgical guide for dental implant placement
    • Becker C.M., and Kaiser D.A. Surgical guide for dental implant placement. J Prosthet Dent 83 (2000) 248-251
    • (2000) J Prosthet Dent , vol.83 , pp. 248-251
    • Becker, C.M.1    Kaiser, D.A.2
  • 16
    • 33746867081 scopus 로고    scopus 로고
    • A surgical guide for dental implant placement in edentulous posterior regions
    • Atsu S.S. A surgical guide for dental implant placement in edentulous posterior regions. J Prosthet Dent 96 (2006) 129-133
    • (2006) J Prosthet Dent , vol.96 , pp. 129-133
    • Atsu, S.S.1
  • 17
    • 0141575639 scopus 로고    scopus 로고
    • Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging
    • Kopp K.C., Koslow A.H., and Abdo O.S. Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. J Prosthet Dent 89 (2003) 611-615
    • (2003) J Prosthet Dent , vol.89 , pp. 611-615
    • Kopp, K.C.1    Koslow, A.H.2    Abdo, O.S.3
  • 18
    • 0035350222 scopus 로고    scopus 로고
    • Fabrication of imaging and surgical guides for dental implants
    • Almog D.M., Torrado E., and Meitner S.W. Fabrication of imaging and surgical guides for dental implants. J Prosthet Dent 85 (2001) 504-508
    • (2001) J Prosthet Dent , vol.85 , pp. 504-508
    • Almog, D.M.1    Torrado, E.2    Meitner, S.W.3
  • 19
    • 0036886962 scopus 로고    scopus 로고
    • A dual-purpose guide for optimum placement of dental implants
    • Cehreli M.C., Calis A.C., and Sahin S. A dual-purpose guide for optimum placement of dental implants. J Prosthet Dent 88 (2002) 640-643
    • (2002) J Prosthet Dent , vol.88 , pp. 640-643
    • Cehreli, M.C.1    Calis, A.C.2    Sahin, S.3
  • 20
    • 34347364569 scopus 로고    scopus 로고
    • CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient
    • Marchack C.B. CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient. J Prosthet Dent 97 (2007) 389-394
    • (2007) J Prosthet Dent , vol.97 , pp. 389-394
    • Marchack, C.B.1
  • 21
    • 50949133388 scopus 로고    scopus 로고
    • Guided implant placement and immediate prosthesis delivery using traditional Branemark System abutments: a pilot study of 23 patients
    • Balshi S.F., Wolfinger G.J., and Balshi T.J. Guided implant placement and immediate prosthesis delivery using traditional Branemark System abutments: a pilot study of 23 patients. Implant Dent 17 (2008) 128-135
    • (2008) Implant Dent , vol.17 , pp. 128-135
    • Balshi, S.F.1    Wolfinger, G.J.2    Balshi, T.J.3
  • 22
    • 44949184646 scopus 로고    scopus 로고
    • Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems
    • Ruppin J., Popovic A., Strauss M., Spüntrup E., Steiner A., and Stoll C. Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems. Clin Oral Implants Res 19 (2008) 709-716
    • (2008) Clin Oral Implants Res , vol.19 , pp. 709-716
    • Ruppin, J.1    Popovic, A.2    Strauss, M.3    Spüntrup, E.4    Steiner, A.5    Stoll, C.6
  • 23
    • 33646271340 scopus 로고    scopus 로고
    • Accuracy in computer-aided implant surgery-a review
    • Widmann G., and Bale R.J. Accuracy in computer-aided implant surgery-a review. Int J Oral Maxillofac Implants 21 (2006) 305-313
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 305-313
    • Widmann, G.1    Bale, R.J.2
  • 24
    • 19044395724 scopus 로고    scopus 로고
    • Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible
    • Wanschitz F., Birkfellner W., Watzinger F., Schopper C., Patruta S., Kainberger F., et al. Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible. Clin Oral Implants Res 13 (2002) 59-64
    • (2002) Clin Oral Implants Res , vol.13 , pp. 59-64
    • Wanschitz, F.1    Birkfellner, W.2    Watzinger, F.3    Schopper, C.4    Patruta, S.5    Kainberger, F.6
  • 26
    • 34548625475 scopus 로고    scopus 로고
    • Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates
    • Nickenig H.J., and Eitner S. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. J Craniomaxillofac Surg 35 (2007) 207-211
    • (2007) J Craniomaxillofac Surg , vol.35 , pp. 207-211
    • Nickenig, H.J.1    Eitner, S.2
  • 27
    • 34548077180 scopus 로고    scopus 로고
    • Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study
    • Van Assche N., van Steenberghe D., Guerrero M.E., Hirsch E., Schutyser F., Quirynen M., et al. Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J Clin Periodontol 34 (2007) 816-821
    • (2007) J Clin Periodontol , vol.34 , pp. 816-821
    • Van Assche, N.1    van Steenberghe, D.2    Guerrero, M.E.3    Hirsch, E.4    Schutyser, F.5    Quirynen, M.6
  • 29
    • 33847284114 scopus 로고    scopus 로고
    • Precision for computer-guided implant placement: using 3D planning software and fixed intraoral reference points
    • Holst S., Blatz M.B., and Eitner S. Precision for computer-guided implant placement: using 3D planning software and fixed intraoral reference points. J Oral Maxillofac Surg 65 (2007) 393-399
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 393-399
    • Holst, S.1    Blatz, M.B.2    Eitner, S.3
  • 30
    • 43049114556 scopus 로고    scopus 로고
    • The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy
    • Vercruyssen M., Jacobs R., Van Assche N., and van Steenberghe D. The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy. J Oral Rehabil 35 (2008) 454-474
    • (2008) J Oral Rehabil , vol.35 , pp. 454-474
    • Vercruyssen, M.1    Jacobs, R.2    Van Assche, N.3    van Steenberghe, D.4
  • 31
    • 0141831249 scopus 로고    scopus 로고
    • Accuracy of implant placement with a stereolithographic surgical guide
    • Sarment D.P., Sukovic P., and Clinthorne N. Accuracy of implant placement with a stereolithographic surgical guide. Int J Oral Maxillofac Implants 18 (2003) 571-577
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 571-577
    • Sarment, D.P.1    Sukovic, P.2    Clinthorne, N.3
  • 33
    • 0037292270 scopus 로고    scopus 로고
    • Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study
    • Vrielinck L., Politis C., Schepers S., Pauwels M., and Naert I. Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study. Int J Oral Maxillofac Surg 32 (2003) 7-14
    • (2003) Int J Oral Maxillofac Surg , vol.32 , pp. 7-14
    • Vrielinck, L.1    Politis, C.2    Schepers, S.3    Pauwels, M.4    Naert, I.5
  • 34
    • 48849084356 scopus 로고    scopus 로고
    • Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results
    • Yong L.T., and Moy P.K. Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results. Clin Implant Dent Relat Res 10 (2008) 123-127
    • (2008) Clin Implant Dent Relat Res , vol.10 , pp. 123-127
    • Yong, L.T.1    Moy, P.K.2
  • 35
    • 7444233720 scopus 로고    scopus 로고
    • Effects of varied dimensions of surgical guides on implant angulations
    • Choi M., Romberg E., and Driscoll C.F. Effects of varied dimensions of surgical guides on implant angulations. J Prosthet Dent 92 (2004) 463-469
    • (2004) J Prosthet Dent , vol.92 , pp. 463-469
    • Choi, M.1    Romberg, E.2    Driscoll, C.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.