Volumn 267, Issue 1-4, 2009, Pages 679-682

Rare earth stearates for wear determination of UHMWPE bearings

Author keywords

Biotribology; Polyethylene; Total joint replacement; Wear; Wear tracers

Indexed keywords

BEARING SURFACES; BIOTRIBOLOGY; COMPONENT MANUFACTURING; CONCENTRATION OF; CONTROL PINS; GRAVIMETRIC MEASUREMENTS; LIFE SPAN; PIN ON DISC; POLYETHYLENE WEAR; PROSTHESIS DESIGN; QUANTIFICATION METHODS; RARE EARTH STEARATES; TOTAL JOINT REPLACEMENT; UHMW-PE; WEAR; WEAR PERFORMANCE; WEAR PREVENTION; WEAR RATES; WEAR TRACERS;

EID: 65749084927     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.wear.2008.12.048     Document Type: Article
Times cited : (9)

References (11)
  • 4
    • 0043065573 scopus 로고    scopus 로고
    • Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene
    • Turell M., Wang A., and Bellare A. Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene. Wear 255 7 (2003) 1034-1039
    • (2003) Wear , vol.255 , Issue.7 , pp. 1034-1039
    • Turell, M.1    Wang, A.2    Bellare, A.3
  • 5
    • 84941911350 scopus 로고    scopus 로고
    • Elsevier Academic Press, San Diego
    • Kurtz S.M. The UHMWPE Handbook (2004), Elsevier Academic Press, San Diego
    • (2004) The UHMWPE Handbook
    • Kurtz, S.M.1
  • 6
    • 0035232592 scopus 로고    scopus 로고
    • Hip simulator wear testing according to newly introduced standard 14242
    • Kaddick C., and Wimmer M.A. Hip simulator wear testing according to newly introduced standard 14242. J. Eng. Med. 215 H5 (2001) 429-442
    • (2001) J. Eng. Med. , vol.215 , Issue.H5 , pp. 429-442
    • Kaddick, C.1    Wimmer, M.A.2
  • 7
    • 0036116447 scopus 로고    scopus 로고
    • Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses
    • Endo M., Tipper J.L., Barton D.C., et al. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. J. Eng. Med. 216 H2 (2002) 111-122
    • (2002) J. Eng. Med. , vol.216 , Issue.H2 , pp. 111-122
    • Endo, M.1    Tipper, J.L.2    Barton, D.C.3
  • 8
    • 0038438249 scopus 로고    scopus 로고
    • A novel method to quantify wear and creep deformation on UHMWPE tibial knee inserts
    • Muratoglu O.K., Perinchief R.S., Konrad R., and Harris W.H. A novel method to quantify wear and creep deformation on UHMWPE tibial knee inserts. TransORS 37 221 (2001)
    • (2001) TransORS , vol.37 , Issue.221
    • Muratoglu, O.K.1    Perinchief, R.S.2    Konrad, R.3    Harris, W.H.4
  • 9
    • 0032619808 scopus 로고    scopus 로고
    • The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory tests
    • Besong A.A., Tipper J.L., and Mathews B.J. The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory tests. J. Eng. Med. 213 H2 (1999) 155-158
    • (1999) J. Eng. Med. , vol.213 , Issue.H2 , pp. 155-158
    • Besong, A.A.1    Tipper, J.L.2    Mathews, B.J.3
  • 10
    • 34248187504 scopus 로고    scopus 로고
    • A tracer method to determine extremely low wear rates of ultrahigh molecular weight polyethylene
    • Kunze J., and Wimmer M.A. A tracer method to determine extremely low wear rates of ultrahigh molecular weight polyethylene. J. ASTM Int. 3 9 (2006) 1-6
    • (2006) J. ASTM Int. , vol.3 , Issue.9 , pp. 1-6
    • Kunze, J.1    Wimmer, M.A.2
  • 11
    • 85196505944 scopus 로고    scopus 로고
    • Europium as a candidate staining material to determine polyethylene wear
    • Wimmer M.A., Ngai V., and Kunze J. Europium as a candidate staining material to determine polyethylene wear. Proc. ASME IMECE (2006) 15376
    • (2006) Proc. ASME IMECE , pp. 15376
    • Wimmer, M.A.1    Ngai, V.2    Kunze, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.