메뉴 건너뛰기




Volumn 91, Issue 3, 2009, Pages 330-335

Treatment delivery time optimization of respiratory gated radiation therapy by application of audio-visual feedback

Author keywords

Breathing synchronized irradiation; Hypo fractionated SBRT; IGRT; Lung cancer

Indexed keywords

ADULT; AGED; ARTICLE; AUDIOVISUAL EQUIPMENT; BREATH HOLDING; CANCER RADIOTHERAPY; CLINICAL ARTICLE; FEEDBACK SYSTEM; HUMAN; LIVER CANCER; LUNG CANCER; PATIENT POSITIONING; PRIORITY JOURNAL; RADIATION DOSE FRACTIONATION; STEREOTACTIC BODY RADIATION THERAPY;

EID: 65649124581     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2009.03.019     Document Type: Article
Times cited : (50)

References (31)
  • 1
    • 0034811943 scopus 로고    scopus 로고
    • Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients
    • Chen Q.S., Weinhous M.S., Deibel F.C., et al. Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. Med Phys 28 (2001) 1850-1856
    • (2001) Med Phys , vol.28 , pp. 1850-1856
    • Chen, Q.S.1    Weinhous, M.S.2    Deibel, F.C.3
  • 2
    • 0028588488 scopus 로고
    • Ultrasound quantitation of respiratory organ motion in the upper abdomen
    • Davies S.C., Hill A.L., Holmes R.B., et al. Ultrasound quantitation of respiratory organ motion in the upper abdomen. Br J Radiol 67 (1994) 1096-1102
    • (1994) Br J Radiol , vol.67 , pp. 1096-1102
    • Davies, S.C.1    Hill, A.L.2    Holmes, R.B.3
  • 3
    • 0026500233 scopus 로고
    • Respiratory kinematics of the upper abdominal organs: a quantitative study
    • Korin H.W., Ehman R.L., Riederer S.J., et al. Respiratory kinematics of the upper abdominal organs: a quantitative study. Magn Reson Med 23 (1992) 172-178
    • (1992) Magn Reson Med , vol.23 , pp. 172-178
    • Korin, H.W.1    Ehman, R.L.2    Riederer, S.J.3
  • 4
    • 0025332165 scopus 로고
    • Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography
    • Ross C.S., Hussey D.H., Pennington E.C., et al. Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. Int. J. Radiat Oncol Biol Phys 18 (1990) 671-677
    • (1990) Int. J. Radiat Oncol Biol Phys , vol.18 , pp. 671-677
    • Ross, C.S.1    Hussey, D.H.2    Pennington, E.C.3
  • 5
    • 0003418872 scopus 로고
    • Prescribing, recording and reporting photon beam therapy
    • International Commission on Radiation Units and Measurements, Bethesda, MD: International Commission on Radiation Units and Measurements;
    • International Commission on Radiation Units and Measurements. Prescribing, recording and reporting photon beam therapy. ICRU Report 50. Bethesda, MD: International Commission on Radiation Units and Measurements; 1993.
    • (1993) ICRU Report , vol.50
  • 6
    • 65649087693 scopus 로고    scopus 로고
    • International Commission on Radiation Units and Measurements. Prescribing, recording and reporting photon beam therapy (supplement to ICRU report 50). ICRU Report 62. Bethesda, MD: International Commission on Radiation Units and Measurements; 1999.
    • International Commission on Radiation Units and Measurements. Prescribing, recording and reporting photon beam therapy (supplement to ICRU report 50). ICRU Report 62. Bethesda, MD: International Commission on Radiation Units and Measurements; 1999.
  • 7
    • 33749265322 scopus 로고    scopus 로고
    • Optimal control of set-up margins and internal margins for intra- and extracranial radiotherapy using stereoscopic kilovoltage imaging
    • Verellen D., Soete G., Linthout N., Tournel K., and Storme G. Optimal control of set-up margins and internal margins for intra- and extracranial radiotherapy using stereoscopic kilovoltage imaging. Cancer Radiother 10 (2006) 235-244
    • (2006) Cancer Radiother , vol.10 , pp. 235-244
    • Verellen, D.1    Soete, G.2    Linthout, N.3    Tournel, K.4    Storme, G.5
  • 8
    • 33748677474 scopus 로고    scopus 로고
    • Setup accuracy of stereoscopic X-ray positioning with automated correction for rotational errors in patients treated with conformal arc radiotherapy for prostate cancer
    • Soete G., Verellen D., Tournel K., and Storme G. Setup accuracy of stereoscopic X-ray positioning with automated correction for rotational errors in patients treated with conformal arc radiotherapy for prostate cancer. Radiother Oncol 80 (2006) 371-373
    • (2006) Radiother Oncol , vol.80 , pp. 371-373
    • Soete, G.1    Verellen, D.2    Tournel, K.3    Storme, G.4
  • 9
    • 33846829586 scopus 로고    scopus 로고
    • X-ray-assisted positioning of patients treated by conformal arc radiotherapy for prostate cancer: comparison of setup accuracy using implanted markers versus bony structures
    • Soete G., De Cock M., Verellen D., Michielsen D., Keuppens F., and Storme G. X-ray-assisted positioning of patients treated by conformal arc radiotherapy for prostate cancer: comparison of setup accuracy using implanted markers versus bony structures. Int J Radiat Oncol Biol Phys 67 (2007) 823-827
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 823-827
    • Soete, G.1    De Cock, M.2    Verellen, D.3    Michielsen, D.4    Keuppens, F.5    Storme, G.6
  • 10
    • 34248640300 scopus 로고    scopus 로고
    • Assessment of secondary patient motion induced by automated couch movement during on-line 6 dimensional repositioning in prostate cancer treatment
    • Linthout N., Verellen D., Tournel K., Reynders T., Duchateau M., and Storme G. Assessment of secondary patient motion induced by automated couch movement during on-line 6 dimensional repositioning in prostate cancer treatment. Radiother Oncol 83 (2007) 168-174
    • (2007) Radiother Oncol , vol.83 , pp. 168-174
    • Linthout, N.1    Verellen, D.2    Tournel, K.3    Reynders, T.4    Duchateau, M.5    Storme, G.6
  • 12
    • 38349078986 scopus 로고    scopus 로고
    • A (short) history of image-guided radiotherapy
    • Verellen D., De Ridder M., and Storme G. A (short) history of image-guided radiotherapy. Radiother Oncol 86 (2008) 4-13
    • (2008) Radiother Oncol , vol.86 , pp. 4-13
    • Verellen, D.1    De Ridder, M.2    Storme, G.3
  • 13
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • Keall P.J., Mageras G.S., Balter J.M., et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 33 (2006) 3874-3900
    • (2006) Med Phys , vol.33 , pp. 3874-3900
    • Keall, P.J.1    Mageras, G.S.2    Balter, J.M.3
  • 14
    • 33646927016 scopus 로고    scopus 로고
    • Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy
    • George R., Chung T.D., Vedam S.S., et al. Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. Int J Radiat Oncol Biol Phys 65 (2006) 924-933
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 924-933
    • George, R.1    Chung, T.D.2    Vedam, S.S.3
  • 15
    • 33748305705 scopus 로고    scopus 로고
    • Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy
    • Willoughby T.R., Forbes A.R., Buchholz D., et al. Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy. Int J Radiat Oncol Biol Phys 66 (2006) 568-575
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 568-575
    • Willoughby, T.R.1    Forbes, A.R.2    Buchholz, D.3
  • 16
    • 33748846271 scopus 로고    scopus 로고
    • Image guided respiratory gated hypofractionated Stereotactic Body Radiation Therapy (H-SBRT) for liver and lung tumors: initial experience
    • Wurm R.E., Gum F., Erbel S., et al. Image guided respiratory gated hypofractionated Stereotactic Body Radiation Therapy (H-SBRT) for liver and lung tumors: initial experience. Acta Oncol 45 (2006) 881-889
    • (2006) Acta Oncol , vol.45 , pp. 881-889
    • Wurm, R.E.1    Gum, F.2    Erbel, S.3
  • 17
    • 4544283239 scopus 로고    scopus 로고
    • Clinical experience using respiratory gated radiation therapy: comparison of free-breathing and breath-hold techniques
    • Berson A.M., Emery R., Rodriguez L., et al. Clinical experience using respiratory gated radiation therapy: comparison of free-breathing and breath-hold techniques. Int J Radiat Oncol Biol Phys 60 (2004) 419-426
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 419-426
    • Berson, A.M.1    Emery, R.2    Rodriguez, L.3
  • 18
    • 0032951630 scopus 로고    scopus 로고
    • Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery
    • Cosgrove V.P., Jahn U., Pfaender M., Bauer S., Budach V., and Wurm R.E. Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery. Radiother Oncol 50 (1999) 325-336
    • (1999) Radiother Oncol , vol.50 , pp. 325-336
    • Cosgrove, V.P.1    Jahn, U.2    Pfaender, M.3    Bauer, S.4    Budach, V.5    Wurm, R.E.6
  • 19
    • 0032925423 scopus 로고    scopus 로고
    • Physical characteristics of a miniature multileaf collimator
    • Xia P., Geis P., Xing L., et al. Physical characteristics of a miniature multileaf collimator. Med Phys 26 (1999) 65-70
    • (1999) Med Phys , vol.26 , pp. 65-70
    • Xia, P.1    Geis, P.2    Xing, L.3
  • 20
    • 0038030020 scopus 로고    scopus 로고
    • Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging
    • Verellen D., Soete G., Linthout N., et al. Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. Radiother Oncol 67 (2003) 129-141
    • (2003) Radiother Oncol , vol.67 , pp. 129-141
    • Verellen, D.1    Soete, G.2    Linthout, N.3
  • 21
    • 0347625753 scopus 로고    scopus 로고
    • A phantom study on the positioning accuracy of the Novalis Body System
    • Yan H., Yin F., and Kim J. A phantom study on the positioning accuracy of the Novalis Body System. Med Phys 30 (2003) 3052-3060
    • (2003) Med Phys , vol.30 , pp. 3052-3060
    • Yan, H.1    Yin, F.2    Kim, J.3
  • 22
    • 33646006995 scopus 로고    scopus 로고
    • Importing measured field fluences into the treatment planning system to validate a breathing synchronized DMLC-IMRT irradiation technique
    • Verellen D., Tournel K., Linthout N., Soete G., Wauters T., and Storme G. Importing measured field fluences into the treatment planning system to validate a breathing synchronized DMLC-IMRT irradiation technique. Radiother Oncol 78 (2006) 332-338
    • (2006) Radiother Oncol , vol.78 , pp. 332-338
    • Verellen, D.1    Tournel, K.2    Linthout, N.3    Soete, G.4    Wauters, T.5    Storme, G.6
  • 23
    • 19944429983 scopus 로고    scopus 로고
    • Percutaneous placement of marking coils before stereotactic radiotherapy of malignant lung lesions
    • De Mey J., Van de Steene J., Vandenbroucke F., et al. Percutaneous placement of marking coils before stereotactic radiotherapy of malignant lung lesions. J Vasc Interv Radiol 16 (2005) 51-56
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 51-56
    • De Mey, J.1    Van de Steene, J.2    Vandenbroucke, F.3
  • 24
    • 0037100122 scopus 로고    scopus 로고
    • Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    • Seppenwoolde Y., Shirato H., Kitamura K., et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 53 (2002) 822-834
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 822-834
    • Seppenwoolde, Y.1    Shirato, H.2    Kitamura, K.3
  • 25
    • 0034762764 scopus 로고    scopus 로고
    • Determining parameters for respiration-gated radiotherapy
    • Vedam S.S., Keall P.J., Kini V.R., et al. Determining parameters for respiration-gated radiotherapy. Med Phys 28 (2001) 2139-2146
    • (2001) Med Phys , vol.28 , pp. 2139-2146
    • Vedam, S.S.1    Keall, P.J.2    Kini, V.R.3
  • 26
    • 0031803931 scopus 로고    scopus 로고
    • Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging
    • Balter J.M., Lam K.L., McGinn C.J., et al. Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. Int J Radiat Oncol Biol Phys 41 (1998) 939-943
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 939-943
    • Balter, J.M.1    Lam, K.L.2    McGinn, C.J.3
  • 27
    • 38149078236 scopus 로고    scopus 로고
    • Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance
    • Korreman S.S., Juhler-Nøttrup T., and Boyer A.L. Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance. Radiother Oncol 86 (2008) 61-68
    • (2008) Radiother Oncol , vol.86 , pp. 61-68
    • Korreman, S.S.1    Juhler-Nøttrup, T.2    Boyer, A.L.3
  • 29
    • 0035450265 scopus 로고    scopus 로고
    • Respiratory-driven lung tumor motion is independent of tumor size, tumor location and pulmonary function
    • Stevens C.W., Munden R.F., Forster K.M., et al. Respiratory-driven lung tumor motion is independent of tumor size, tumor location and pulmonary function. Int J Radiat Oncol Biol Phys 51 (2001) 62-68
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 62-68
    • Stevens, C.W.1    Munden, R.F.2    Forster, K.M.3
  • 30
    • 0034255586 scopus 로고    scopus 로고
    • The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer
    • Rosenzweig K.E., Hanley J., Mah D., et al. The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 48 (2000) 81-87
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 81-87
    • Rosenzweig, K.E.1    Hanley, J.2    Mah, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.