-
1
-
-
0033767396
-
The Danish Hip Arthroplasty Register
-
10.1080/000164700317381081 11186396
-
The Danish Hip Arthroplasty Register. U Lucht, Acta Orthop Scand 2000 71 433 439 10.1080/000164700317381081 11186396
-
(2000)
Acta Orthop Scand
, vol.71
, pp. 433-439
-
-
Lucht, U.1
-
4
-
-
1842406624
-
The theory of early loosening of hip prostheses
-
The theory of early loosening of hip prostheses. B Mjöberg, Orthopedics 1997 20 1169 1175 9415912 (Pubitemid 27521670)
-
(1997)
Orthopedics
, vol.20
, Issue.12
, pp. 1169-1175
-
-
Mjoberg, B.1
-
5
-
-
0026832935
-
Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
-
10.1002/jor.1100100216 1311039
-
Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. K Søballe ES Hansen HB Rassmussen PH Jorgensen C Bunger, J Orthop Res 1992 10 285 299 10.1002/jor.1100100216 1311039
-
(1992)
J Orthop Res
, vol.10
, pp. 285-299
-
-
Søballe, K.1
Hansen, E.S.2
Rassmussen, H.B.3
Jorgensen, P.H.4
Bunger, C.5
-
7
-
-
0027610622
-
The relation between resonant frequencies and torsional stiffness of long bones in vitro. Validation of a simple beam model
-
DOI 10.1016/0021-9290(93)90032-A
-
The relation between resonant frequencies and torsional stiffness of long bones in vitro. Validation of a simple beam model. G Lowet R Van Audekercke G Van der Perre P Geusens J Dequeker J Lammens, J Biomech 1993 26 689 696 10.1016/0021-9290(93)90032-A 8514813 (Pubitemid 23162357)
-
(1993)
Journal of Biomechanics
, vol.26
, Issue.6
, pp. 689-696
-
-
Lowet, G.1
Van Audekercke, R.2
Van Der Perre, G.3
Geusens, P.4
Dequeker, J.5
Lammens, J.6
-
8
-
-
0030271192
-
Ultrasound velocity measurement in long bones: Measurement method and simulation of ultrasound wave propagation
-
DOI 10.1016/0021-9290(96)00054-1
-
Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation. G Lowet G Van der Perre, J Biomech 1996 29 1255 1262 10.1016/0021-9290(96)00054-1 8884471 (Pubitemid 26302371)
-
(1996)
Journal of Biomechanics
, vol.29
, Issue.10
, pp. 1255-1262
-
-
Lowet, G.1
Van Der Perre, G.2
-
9
-
-
0020652002
-
On the mechanical resonance of a human tibia in vitro
-
10.1016/0021-9290(83)90069-6 6619172
-
On the mechanical resonance of a human tibia in vitro. G Van der Perre P Cornelissen, J Biomech 1983 16 549 10.1016/0021-9290(83)90069-6 6619172
-
(1983)
J Biomech
, vol.16
, pp. 549
-
-
Der V., P.G.1
Cornelissen, P.2
-
11
-
-
0025270653
-
Monitoring of fracture healing by lateral and axial vibration analysis
-
DOI 10.1016/0021-9290(90)90060-G
-
Monitoring of fracture healing by lateral and axial vibration analysis. G Nikiforidis A Bezerianos A Dimarogonas C Sutherland, J Biomech 1990 23 323 330 10.1016/0021-9290(90)90060-G 2335530 (Pubitemid 20162538)
-
(1990)
Journal of Biomechanics
, vol.23
, Issue.4
, pp. 323-330
-
-
Nikiforidis, G.1
Bezerianos, A.2
Dimarogonas, A.3
Sutherland, C.4
-
12
-
-
0038108004
-
The use of externally applied mechanical vibrations to assess both fractures and hip prosthesis
-
Oxford Univ. Press Turner-Smith R
-
The use of externally applied mechanical vibrations to assess both fractures and hip prosthesis. J Collier J Donarski J Worley A Lay, Micromovement in Orthopaedics Oxford Univ. Press, Turner-Smith R, 1993 151 163
-
(1993)
Micromovement in Orthopaedics
, pp. 151-163
-
-
Collier, J.1
Donarski, J.2
Worley, J.3
Lay, A.4
-
13
-
-
0029681729
-
Assessment of Fracture Healing in the Tibia Using the Impulse Response Method
-
Assessment of fracture healing in the tibia using the impulse response method. Y Nakatsuchi A Tsuchikane A Nomura, J Orthop Trauma 1996 10 50 62 10.1097/00005131-199601000-00008 8926555 (Pubitemid 126432665)
-
(1996)
Journal of Orthopaedic Trauma
, vol.10
, Issue.1
, pp. 50-62
-
-
Nakatsuchi, Y.1
Tsuchikane, A.2
Nomura, A.3
-
14
-
-
0030068851
-
In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis
-
In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. G Van der Perre G Lowet, Bone 1996 18 1 Suppl 29S 35S 8717545 (Pubitemid 26047541)
-
(1996)
Bone
, vol.18
, Issue.SUPPL. 1
-
-
Van Der Perre, G.1
Lowet, G.2
-
15
-
-
0031152150
-
Resonance frequency measurements of implant stability in vivo: A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
-
Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. N Meredith K Book B Friberg T Jemt L Sennerby, Clin Oral Implants Res 1997 8 226 233 10.1034/j.1600-0501.1997.080309.x 9586467 (Pubitemid 127688458)
-
(1997)
Clinical Oral Implants Research
, vol.8
, Issue.3
, pp. 226-233
-
-
Meredith, N.1
Book, K.2
Friberg, B.3
Jemt, T.4
Sennerby, L.5
-
16
-
-
65549125022
-
STIMuLus: Smart Total Implant for the Monitoring of Loosening [abstract]
-
STIMuLus: Smart Total Implant for the Monitoring of Loosening [abstract]. F Burny M Donkerwolcke F Moulart A Borgwardt P Vryzakis D Pichon R Collier S Louridas G Van der Perre I Denayer S Jaecques M Catrysse R Puers, Medical Physics 2000 27 1406
-
(2000)
Medical Physics
, vol.27
, pp. 1406
-
-
Burny, F.1
Donkerwolcke, M.2
Moulart, F.3
Borgwardt, A.4
Vryzakis, P.5
Pichon, D.6
Collier, R.7
Louridas, S.8
Der V., P.G.9
Denayer, I.10
Jaecques, S.11
Catrysse, M.12
Puers, R.13
-
17
-
-
0034997894
-
Accurate diagnosis of hip prosthesis loosening using a vibrational technique
-
DOI 10.1016/S0268-0033(01)00002-X, PII S026800330100002X
-
Accurate diagnosis of hip prosthesis loosening using a vibrational technique. AP Georgiou JL Cunningham, Clin Biomech (Bristol, Avon) 2001 16 315 323 10.1016/S0268-0033(01)00002-X 11358619 (Pubitemid 32453160)
-
(2001)
Clinical Biomechanics
, vol.16
, Issue.4
, pp. 315-323
-
-
Georgiou, A.P.1
Cunningham, J.L.2
-
18
-
-
0024795184
-
Differentiation of loose and secure femoral implants in total hip replacement using a vibrational technique. An anatomical and pilot clinical study
-
The differentiation of loose and secure femoral implants in total hip replacement using a vibrational technique: an anatomical and pilot clinical study. AD Rosenstein GF McCoy CJ Bulstrode PD McLardy-Smith JL Cunningham AR Turner Smith, Proc Inst Mech Eng [H] 1989 203 77 81 2619838 (Pubitemid 20656552)
-
(1989)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.203
, Issue.2
, pp. 77-81
-
-
Rosenstein, A.D.1
Bulstrode, C.J.2
McLardy-Smith, P.D.3
Cunningham, J.L.4
Turner-Smith, A.R.5
-
19
-
-
39849097996
-
Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening
-
10.1016/j.medengphy.2007.04.017 17587635
-
Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening. A Rowlands FA Duck JL Cunningham, Med Eng Phys 2008 30 278 284 10.1016/j.medengphy.2007.04.017 17587635
-
(2008)
Med Eng Phys
, vol.30
, pp. 278-284
-
-
Rowlands, A.1
Duck, F.A.2
Cunningham, J.L.3
-
20
-
-
34250161649
-
Intra-operative evaluation of cementless hip implant stability: A prototype device based on vibration analysis
-
DOI 10.1016/j.medengphy.2006.09.011, PII S1350453306002037
-
Intra-operative evaluation of cementless hip implant stability: A prototype device based on vibration analysis. M Lannocca E Varini A Cappello L Cristofolini E Bialoblocka, Med Eng Phys 2007 29 886 894 10.1016/j.medengphy. 2006.09.011 17101289 (Pubitemid 46898905)
-
(2007)
Medical Engineering and Physics
, vol.29
, Issue.8
, pp. 886-894
-
-
Lannocca, M.1
Varini, E.2
Cappello, A.3
Cristofolini, L.4
Bialoblocka, E.5
-
21
-
-
13344285312
-
Analysis of the fixation quality of cementless hip prostheses using a vibrational technique
-
Leuven: K.U. Leuven Sas P, De Munck M
-
Analysis of the fixation quality of cementless hip prostheses using a vibrational technique. S Jaecques C Pastrav A Zahariuc G Van der Perre, Proceedings of ISMA 2004 International Conference on Noise and vibration engineering: 20-22 September 2004; Leuven Leuven: K.U. Leuven, Sas P, De Munck M, 2004 443 456
-
(2004)
Proceedings of ISMA 2004 International Conference on Noise and Vibration Engineering: 20-22 September 2004; Leuven
, pp. 443-456
-
-
Jaecques, S.1
Pastrav, C.2
Zahariuc, A.3
Der V., P.G.4
-
22
-
-
65549153221
-
Determination of THR stem insertion endpoint by vibrational analysis
-
Lisbon: Soc Portugesa de Ortopedia e Traumatologia Cabral R, Cassiano NM, Camilo C
-
Determination of THR stem insertion endpoint by vibrational analysis. S Jaecques C Pastrav M Mulier G Van der Perre, EORS - Transactions, Proceedings of 15th Annual Meeting of European Orthopaedic Research Society - EORS 2005; Lisbon Lisbon: Soc Portugesa de Ortopedia e Traumatologia, Cabral R, Cassiano NM, Camilo C, 2005 92
-
(2005)
EORS - Transactions, Proceedings of 15th Annual Meeting of European Orthopaedic Research Society - EORS 2005; Lisbon
, pp. 92
-
-
Jaecques, S.1
Pastrav, C.2
Mulier, M.3
Der V., P.G.4
-
23
-
-
62849085819
-
A system for intra operative manufacturing and stability testing of hip prostheses
-
Suceava: University of Suceava Dumitru I
-
A system for intra operative manufacturing and stability testing of hip prostheses. C Pastrav S Jaecques G Deloge M Mulier G Van der Perre, Proceedings of TEHNOMUS XIII, the 13th International conference on New technologies and products in machine manufacturing technology: 6-7 May 2005; Suceava Suceava: University of Suceava, Dumitru I, 2005 505 510
-
(2005)
Proceedings of TEHNOMUS XIII, the 13th International Conference on New Technologies and Products in Machine Manufacturing Technology: 6-7 May 2005; Suceava
, pp. 505-510
-
-
Pastrav, C.1
Jaecques, S.2
Deloge, G.3
Mulier, M.4
Der V., P.G.5
-
24
-
-
52949136300
-
Detection of the insertion end point of cementless hip prostheses using the comparison between successive frequency response functions
-
Detection of the insertion end point of cementless hip prostheses using the comparison between successive frequency response functions. LC Pastrav SVN Jaecques M Mulier G Va der Perre, Journal of Applied Biomaterials & Biomechanics 2008 6 23 29
-
(2008)
Journal of Applied Biomaterials & Biomechanics
, vol.6
, pp. 23-29
-
-
Pastrav, L.C.1
Jaecques, S.V.N.2
Mulier, M.3
Va Der Perre, G.4
-
25
-
-
65549095921
-
The influence of contact conditions on resonance frequencies of a hip stem-femur system: A finite element analysis
-
Leuven: K.U. Leuven Jonkers I, Jaecques S, Mulier M, Van der Perre G
-
The influence of contact conditions on resonance frequencies of a hip stem-femur system: a finite element analysis. J Devos S Jaecques C Pastrav G Van der Perre, Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22-23 June 2007; Leuven Leuven: K.U. Leuven, Jonkers I, Jaecques S, Mulier M, Van der Perre G, 2007 35 36
-
(2007)
Proceedings of the International Seminar Prediction and Evaluation of Total Hip Replacement Performance: Can We Plan Success? 22-23 June 2007; Leuven
, pp. 35-36
-
-
Devos, J.1
Jaecques, S.2
Pastrav, C.3
Der V., P.G.4
-
26
-
-
0038246468
-
How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening?
-
DOI 10.1016/S0268-0033(03)00051-2
-
How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening? G Qi W Mouchon TE Tan, Clin Biomech (Bristol, Avon). 2003 18 5 444 458 10.1016/S0268-0033(03)00051-2 12763441 (Pubitemid 36583591)
-
(2003)
Clinical Biomechanics
, vol.18
, Issue.5
, pp. 444-458
-
-
Qi, G.1
Mouchon, W.P.2
Tan, T.E.3
-
27
-
-
0024958749
-
A new system to produce intraoperatively custom femoral prosthesis from measurements taken during the surgical procedure
-
A new system to produce intraoperatively custom femoral prosthesis from measurements taken during the surgical procedure. JC Mulier M Mulier LP Brady H Steenhoudt Y Cauwe M Goossens M Elloy, Clin Orthop Relat Res 1989 249 97 112 2582680 (Pubitemid 20199760)
-
(1989)
Clinical Orthopaedics and Related Research
, Issue.249
, pp. 97-112
-
-
Mulier, J.C.1
Mulier, M.2
Brady, L.P.3
Steenhoudt, H.4
Cauwe, Y.5
Goossens, M.6
Elloy, M.7
-
29
-
-
65549124128
-
Intraoperative manufactured hip prosthesis insertion - A finite element simulation
-
Leuven: K.U. Leuven Jonkers I, Jaecques S, Mulier M, Van der Perre G
-
Intraoperative manufactured hip prosthesis insertion - a finite element simulation. A Asiminei C Pastrav S Jaecques M Mulier G Van der Perre, Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22-23 June 2007; Leuven Leuven: K.U. Leuven, Jonkers I, Jaecques S, Mulier M, Van der Perre G, 2007 28 30
-
(2007)
Proceedings of the International Seminar Prediction and Evaluation of Total Hip Replacement Performance: Can We Plan Success? 22-23 June 2007; Leuven
, pp. 28-30
-
-
Asiminei, A.1
Pastrav, C.2
Jaecques, S.3
Mulier, M.4
Der V., P.G.5
-
30
-
-
65549111317
-
Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups
-
Leuven: K.U. Leuven Jonkers I, Jaecques S, Mulier M, Van der Perre G
-
Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups. W Claassen J Nijs S Jaecques G Van der Perre M Mulier, Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22-23 June 2007; Leuven Leuven: K.U. Leuven, Jonkers I, Jaecques S, Mulier M, Van der Perre G, 2007 6 8
-
(2007)
Proceedings of the International Seminar Prediction and Evaluation of Total Hip Replacement Performance: Can We Plan Success? 22-23 June 2007; Leuven
, pp. 6-8
-
-
Claassen, W.1
Nijs, J.2
Jaecques, S.3
Der V., P.G.4
Mulier, M.5
-
31
-
-
65549142709
-
Follow-up of implant performance using RSA
-
Leuven: K.U. Leuven Jonkers I, Jaecques S, Mulier M, Van der Perre G
-
Follow-up of implant performance using RSA. W Claassen J Nijs M Mulier S Jaecques G Van der Perre, Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22-23 June 2007; Leuven Leuven: K.U. Leuven, Jonkers I, Jaecques S, Mulier M, Van der Perre G, 2007 2 5
-
(2007)
Proceedings of the International Seminar Prediction and Evaluation of Total Hip Replacement Performance: Can We Plan Success? 22-23 June 2007; Leuven
, pp. 2-5
-
-
Claassen, W.1
Nijs, J.2
Mulier, M.3
Jaecques, S.4
Der V., P.G.5
|