-
1
-
-
0001488433
-
The use of auscultatory percussion for the examination of fractures
-
Lippmann RK. The use of auscultatory percussion for the examination of fractures, J Bone Joint Surg 1932; 14, 118.
-
(1932)
J Bone Joint Surg
, vol.14
, pp. 118
-
-
Lippmann, R.K.1
-
2
-
-
0027610622
-
The relation between resonant frequencies and torsional stiffness of long bones in vitro. Validation of a simple beam model
-
Lowet G, Van Audekercke R, Van Der Perre G, Geusens P, Dequeker J, Lammens J. The relation between resonant frequencies and torsional stiffness of long bones in vitro. Validation of a simple beam model. J Biomech 1993; 26: 689-96.
-
(1993)
J Biomech
, vol.26
, pp. 689-696
-
-
Lowet, G.1
Van Audekercke, R.2
Van Der Perre, G.3
Geusens, P.4
Dequeker, J.5
Lammens, J.6
-
3
-
-
0030271192
-
Ultrasound velocity measurement in long bones: Measurement method and simulation of ultrasound wave propagation
-
Lowet G, Van Der Perre G. Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation. J Biomech 1996; 29: 1255-62.
-
(1996)
J Biomech
, vol.29
, pp. 1255-1262
-
-
Lowet, G.1
Van Der Perre, G.2
-
4
-
-
0030221980
-
Study of the vibrational behaviour of a healing tibia using finite element modelling
-
Lowet G, Dayuan X, Van der Perre G. Study of the vibrational behaviour of a healing tibia using finite element modelling. J Biomech 1996; 29: 1003-10.
-
(1996)
J Biomech
, vol.29
, pp. 1003-1010
-
-
Lowet, G.1
Dayuan, X.2
Van der Perre, G.3
-
5
-
-
0032605516
-
The use of low-frequency vibration measurement in orthopaedics
-
Nokes LDM. The use of low-frequency vibration measurement in orthopaedics. Proc Instn Mech Eng [H] 1999; 213: 271-90.
-
(1999)
Proc Instn Mech Eng [H]
, vol.213
, pp. 271-290
-
-
Nokes, L.D.M.1
-
7
-
-
0029681729
-
Assessment of fracture healing in the tibia using the impulse response method
-
Nakatsuchi Y, Tsuchikane A, Nomura A. Assessment of fracture healing in the tibia using the impulse response method. J Orthop Trauma 1996; 10: 50-62.
-
(1996)
J Orthop Trauma
, vol.10
, pp. 50-62
-
-
Nakatsuchi, Y.1
Tsuchikane, A.2
Nomura, A.3
-
8
-
-
0030068851
-
In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation
-
Van Der Perre G, Lowet G. In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation. Bone 1996; 18: S29-35.
-
(1996)
Bone
, vol.18
-
-
Van Der Perre, G.1
Lowet, G.2
-
9
-
-
0030045753
-
Noninvasive determination of bone mechanical properties using vibration response: A refined model and validation in vivo
-
Roberts SG, Hutchinson TM, Arnaud SB, Kiratli BJ, Martin RB, Steele CR. Noninvasive determination of bone mechanical properties using vibration response: A refined model and validation in vivo. J Biomech 1996; 29:91-8.
-
(1996)
J Biomech
, vol.29
, pp. 91-98
-
-
Roberts, S.G.1
Hutchinson, T.M.2
Arnaud, S.B.3
Kiratli, B.J.4
Martin, R.B.5
Steele, C.R.6
-
10
-
-
0031152189
-
The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
-
Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implant Res 1997; 8: 234-43.
-
(1997)
Clin Oral Implant Res
, vol.8
, pp. 234-243
-
-
Meredith, N.1
Shagaldi, F.2
Alleyne, D.3
Sennerby, L.4
Cawley, P.5
-
11
-
-
32644436644
-
The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach
-
Pattijn V, Van Lierde C, Van der Perre G, Naert I, Vander Sloten J. The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach. J Biomech 2006; 39: 939-47.
-
(2006)
J Biomech
, vol.39
, pp. 939-947
-
-
Pattijn, V.1
Van Lierde, C.2
Van der Perre, G.3
Naert, I.4
Vander Sloten, J.5
-
13
-
-
0002340912
-
Dynamic analysis of human bones
-
Ducheyne P, Hastings GW, eds, Boca Raton: CRC Press
-
Van der Perre G. Dynamic analysis of human bones. In Ducheyne P, Hastings GW, eds. Functional behaviour of orthopaedic biomaterials; Vol I Boca Raton: CRC Press, 1984; 99-159.
-
(1984)
Functional behaviour of orthopaedic biomaterials
, vol.1
, pp. 99-159
-
-
Van der Perre, G.1
-
14
-
-
0024795184
-
The differentiation of loose and secure femoral implants in total hip replacement using a vibrational technique: An anatomical and pilot clinical study
-
Rosenstein AD, McCoy GF, Bulstrode CJ, McLardy-Smith PD, Cunningham JL, Turner-Smith AR. The differentiation of loose and secure femoral implants in total hip replacement using a vibrational technique: An anatomical and pilot clinical study. Proc Inst Mech Eng 1989; 203: 77-81.
-
(1989)
Proc Inst Mech Eng
, vol.203
, pp. 77-81
-
-
Rosenstein, A.D.1
McCoy, G.F.2
Bulstrode, C.J.3
McLardy-Smith, P.D.4
Cunningham, J.L.5
Turner-Smith, A.R.6
-
15
-
-
0038108004
-
The use of externally applied mechanical vibrations to assess both fractures and hip prosthesis
-
Turner-Smith AR, ed, Oxford: OUP
-
Collier RJ, Donarski RJ, Worley AJ, Lay A. The use of externally applied mechanical vibrations to assess both fractures and hip prosthesis. In Turner-Smith AR, ed. Micro-movement in Orthopaedics. Oxford: OUP, 1993; 151-63.
-
(1993)
Micro-movement in Orthopaedics
, pp. 151-163
-
-
Collier, R.J.1
Donarski, R.J.2
Worley, A.J.3
Lay, A.4
-
16
-
-
0029017372
-
Loosening of total hip arthroplasty; diagnosis by vibration analysis
-
Li PL, Jones NB, Gregg PJ. Loosening of total hip arthroplasty; diagnosis by vibration analysis. J Bone Joint Surg Br 1995; 77: 640-4.
-
(1995)
J Bone Joint Surg Br
, vol.77
, pp. 640-644
-
-
Li, P.L.1
Jones, N.B.2
Gregg, P.J.3
-
17
-
-
0030271435
-
Vibration analysis in the detection of total hip prosthetic loosening
-
Li PL, Jones NB, Gregg PJ. Vibration analysis in the detection of total hip prosthetic loosening. Med Eng Phys 1996; 18: 596-600.
-
(1996)
Med Eng Phys
, vol.18
, pp. 596-600
-
-
Li, P.L.1
Jones, N.B.2
Gregg, P.J.3
-
18
-
-
0034997894
-
Accurate diagnosis of hip prosthesis loosening using a vibrational technique
-
Georgiou AP, Cunningham JL. Accurate diagnosis of hip prosthesis loosening using a vibrational technique. Clin Biomech (Bristol, Avon) 2001; 16: 315-23.
-
(2001)
Clin Biomech (Bristol, Avon)
, vol.16
, pp. 315-323
-
-
Georgiou, A.P.1
Cunningham, J.L.2
-
19
-
-
1342333881
-
Measurement of implant stability and osseointegration: Non-linearities and resonance frequencies
-
Prendergast PJ, Lee TC, Carr AJ, eds, Dublin
-
Denayer I, Jaecques SVN, Burny F, Puers R, Borgwardt A, Van der Perre G. Measurement of implant stability and osseointegration: Non-linearities and resonance frequencies. In: Prendergast PJ, Lee TC, Carr AJ, eds. Proc 12th ConfEur Soc Biomech Dublin 2000; pp. 151.
-
(2000)
Proc 12th ConfEur Soc Biomech
, pp. 151
-
-
Denayer, I.1
Jaecques, S.V.N.2
Burny, F.3
Puers, R.4
Borgwardt, A.5
Van der Perre, G.6
-
20
-
-
0038246468
-
-
Bristol, Avon
-
Qi G, Mouchon WP, Tan TE, How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening? Clin Biomechs (Bristol, Avon) 2003; 18: 444-58.
-
(2003)
How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening? Clin Biomechs
, vol.18
, pp. 444-458
-
-
Qi, G.1
Mouchon, W.P.2
Tan, T.E.3
-
21
-
-
1442356148
-
Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem
-
Meek RM, Garbuz DS, Masri BA, Greidanus NV, Duncan CP. Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. J Bone Joint Surg Am 2004; 86A: 480-5.
-
(2004)
J Bone Joint Surg Am
, vol.86 A
, pp. 480-485
-
-
Meek, R.M.1
Garbuz, D.S.2
Masri, B.A.3
Greidanus, N.V.4
Duncan, C.P.5
-
23
-
-
13344285312
-
Analysis of the fixation quality of cementless hip prostheses using a vibrational technique
-
Sas P, De Munck M, eds
-
Jaecques SVN, Pastrav C, Vegehan E, Van der Perre G. Analysis of the fixation quality of cementless hip prostheses using a vibrational technique. In: Sas P, De Munck M, eds. Proceedings of ISMA2004 International Conference on Noise and Vibration Engineering, September 20-22, 2004. Belgium: KU Leuven, ISBN 90-73802-82-2; 443-56.
-
Proceedings of ISMA2004 International Conference on Noise and Vibration Engineering, September 20-22, 2004. Belgium: KU Leuven, ISBN 90-73802-82-2
, pp. 443-456
-
-
Jaecques, S.V.N.1
Pastrav, C.2
Vegehan, E.3
Van der Perre, G.4
-
24
-
-
34250200290
-
Primary stability assessment in hip arthroplasty-a device based on the vibrational techniquc
-
Varini E. Lannocca M. Bialoblocka E. Cappello A. Cristofolini L. Primary stability assessment in hip arthroplasty-a device based on the vibrational techniquc. J Biomech 2006; 39 (suppl 1): S127.
-
(2006)
J Biomech
, vol.39
, Issue.SUPPL. 1
-
-
Varini, E.1
Lannocca, M.2
Bialoblocka, E.3
Cappello, A.4
Cristofolini, L.5
-
25
-
-
0034922981
-
Structural properties of a new design of composite replicate femurs and tibias
-
Heiner AD, Brown TD. Structural properties of a new design of composite replicate femurs and tibias. J Biomech 2001; 34: 773-81.
-
(2001)
J Biomech
, vol.34
, pp. 773-781
-
-
Heiner, A.D.1
Brown, T.D.2
-
27
-
-
0003391392
-
Optimum signal processing
-
Englewood Cliffs, NJ: Prentice-Hall
-
Orfanidis SJ. Optimum signal processing. An introduction. Englewood Cliffs, NJ: Prentice-Hall, 1996.
-
(1996)
An introduction
-
-
Orfanidis, S.J.1
|