메뉴 건너뛰기




Volumn 11, Issue 5, 2009, Pages 460-463

Lipohypertrophy: Does it matter in daily life? A study using a continuous glucose monitoring system

Author keywords

Continuous blood glucose monitoring; Glycaemic control; Lipohypertrophy

Indexed keywords

GLUCOSE; INSULIN;

EID: 65449130419     PISSN: 14628902     EISSN: 14631326     Source Type: Journal    
DOI: 10.1111/j.1463-1326.2008.00972.x     Document Type: Article
Times cited : (28)

References (10)
  • 1
    • 0037518410 scopus 로고    scopus 로고
    • Glucose sensor evaluation of glycemic instability in pediatric type 1 diabetes mellitus
    • Alemzadeh R, Loppnow C, Parton E, Kirby M. Glucose sensor evaluation of glycemic instability in pediatric type 1 diabetes mellitus. Diabetes Technol Ther 2003; 5: 167-173.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 167-173
    • Alemzadeh, R.1    Loppnow, C.2    Parton, E.3    Kirby, M.4
  • 2
    • 23044452157 scopus 로고    scopus 로고
    • Impaired absorption of insulin aspart from lipohypertrophic injection sites
    • Johansson UB, Amsberg S, Hannerz L et al. Impaired absorption of insulin aspart from lipohypertrophic injection sites. Diabetes Care 2005; 28: 2025-2027.
    • (2005) Diabetes Care , vol.28 , pp. 2025-2027
    • Johansson, U.B.1    Amsberg, S.2    Hannerz, L.3
  • 3
    • 0025002028 scopus 로고
    • Morphology of palpably abnormal injection sites and effects on absorption of isophane (NPH) insulin
    • Thow JC, Johnson AB, Marsden S, Taylor R, Home PD. Morphology of palpably abnormal injection sites and effects on absorption of isophane (NPH) insulin. Diabet Med 1990; 7: 795-799.
    • (1990) Diabet Med , vol.7 , pp. 795-799
    • Thow, J.C.1    Johnson, A.B.2    Marsden, S.3    Taylor, R.4    Home, P.D.5
  • 4
    • 0015802619 scopus 로고
    • A comparison of acid regular and neutral insulin. Responses of normal fasted subjects to varying doses of regular insulin
    • Galloway JA, Root MA, Rathmacher RP, Carmichael MS. A comparison of acid regular and neutral insulin. Responses of normal fasted subjects to varying doses of regular insulin. Diabetes 1973; 22: 471-479.
    • (1973) Diabetes , vol.22 , pp. 471-479
    • Galloway, J.A.1    Root, M.A.2    Rathmacher, R.P.3    Carmichael, M.S.4
  • 5
    • 0019943337 scopus 로고
    • Absorption of isophane (NPH) insulin and its clinical implications
    • Lauritzen T, Pramming S, Gale EA, Deckert T, Binder C. Absorption of isophane (NPH) insulin and its clinical implications. BMJ 1982; 285: 159-162.
    • (1982) BMJ , vol.285 , pp. 159-162
    • Lauritzen, T.1    Pramming, S.2    Gale, E.A.3    Deckert, T.4    Binder, C.5
  • 6
    • 0031784896 scopus 로고    scopus 로고
    • Variability of the metabolic effect of soluble insulin and the rapid acting insulin analogue insulin aspart
    • Heinmann L, Weyer C, Rauhaus M, Heinrichs S, Heise T. Variability of the metabolic effect of soluble insulin and the rapid acting insulin analogue insulin aspart. Diabetes Care 1998; 21: 1910-1914.
    • (1998) Diabetes Care , vol.21 , pp. 1910-1914
    • Heinmann, L.1    Weyer, C.2    Rauhaus, M.3    Heinrichs, S.4    Heise, T.5
  • 7
    • 2542576404 scopus 로고    scopus 로고
    • Lower within-subject variability of insulin detemir in comparison to NPH insulin and insulin glargine in people with type 1 diabetes
    • Heise T, Nosek L, Ronn BB et al. Lower within-subject variability of insulin detemir in comparison to NPH insulin and insulin glargine in people with type 1 diabetes. Diabetes 2004; 53: 1614-1620.
    • (2004) Diabetes , vol.53 , pp. 1614-1620
    • Heise, T.1    Nosek, L.2    Ronn, B.B.3
  • 8
  • 9
    • 1542439960 scopus 로고    scopus 로고
    • Performance assessment of the Medtronic-MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in diabetic subjects
    • Sachedina N, Pickup JC. Performance assessment of the Medtronic-MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in diabetic subjects. Diabet Med 2003; 20: 1012-1015.
    • (2003) Diabet Med , vol.20 , pp. 1012-1015
    • Sachedina, N.1    Pickup, J.C.2
  • 10
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • Rebrin K, Steil GM, van Antwerp WP, Mastrototaro JJ. Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring. Am J Physiol 1999; 277: E561-E571.
    • (1999) Am J Physiol , vol.277
    • Rebrin, K.1    Steil, G.M.2    van Antwerp, W.P.3    Mastrototaro, J.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.