메뉴 건너뛰기




Volumn 7168, Issue , 2009, Pages

Flow measurement by using the signal decrease of moving scatterers in spatially encoded fourier domain optical coherence tomography

Author keywords

FD OCT; Flow measurement; Non invasive; Oblique sample motion; Signal power decrease

Indexed keywords

BLOOD FLOW MEASUREMENTS; DEPTH-RESOLVED; DOPPLER OCT; FD-OCT; FLOW PHANTOMS; FLOW SENSITIVITIES; FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHIES; GLASS CAPILLARIES; HIGH FLOW VELOCITIES; INDUCED SIGNALS; INTRALIPID; NON-INVASIVE; OBLIQUE SAMPLE MOTION; PHANTOM STUDIES; PHASE INFORMATIONS; SIGNAL DAMPING; SIGNAL DECAYS; SIGNAL POWER DECREASE; TRANSVERSE COMPONENTS; TRANSVERSE EFFECTS;

EID: 65349159206     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.808737     Document Type: Conference Paper
Times cited : (7)

References (20)
  • 1
    • 4644298765 scopus 로고    scopus 로고
    • Motion artifacts in optical coherence tomography with frequency-domain ranging
    • Yun, S. H., Tearney, G. J., de Boer, J. F. and Bouma, B. E., "Motion artifacts in optical coherence tomography with frequency-domain ranging," Opt. Express 12, 2977-2998 (2004).
    • (2004) Opt. Express , vol.12 , pp. 2977-2998
    • Yun, S.H.1    Tearney, G.J.2    de Boer, J.F.3    Bouma, B.E.4
  • 2
    • 33846519303 scopus 로고    scopus 로고
    • Resonant Doppler flow imaging and optical vivisection of retinal blood vessels
    • Bachmann, A. H., Villiger, M. L., Blatter, C., Lasser, T. and Leitgeb, R. A., "Resonant Doppler flow imaging and optical vivisection of retinal blood vessels," Opt. Express 15, 408-422 (2007).
    • (2007) Opt. Express , vol.15 , pp. 408-422
    • Bachmann, A.H.1    Villiger, M.L.2    Blatter, C.3    Lasser, T.4    Leitgeb, R.A.5
  • 3
    • 59049096490 scopus 로고    scopus 로고
    • Effects of axial, transverse and oblique sample motion in FDOCT in systems with global or rolling shutter line detector
    • Walther, J., Krüger, A., Cuevas, M. and Koch, E., "Effects of axial, transverse and oblique sample motion in FDOCT in systems with global or rolling shutter line detector," J. Opt. Soc. Am. A 25 (11), 2791-2802 (2008).
    • (2008) J. Opt. Soc. Am. A , vol.25 , Issue.11 , pp. 2791-2802
    • Walther, J.1    Krüger, A.2    Cuevas, M.3    Koch, E.4
  • 4
    • 0037088454 scopus 로고    scopus 로고
    • Imaging and quantifying transverse flow velocity with the Doppler bandwidth in a phase-resolved functional optical coherence tomography
    • Ren, H., Brecke, K. M., Ding, Z., Zhao, Y., Nelson, J. S. and Chen, Z., "Imaging and quantifying transverse flow velocity with the Doppler bandwidth in a phase-resolved functional optical coherence tomography," Opt. Lett., 27, 409-411 (2002).
    • (2002) Opt. Lett , vol.27 , pp. 409-411
    • Ren, H.1    Brecke, K.M.2    Ding, Z.3    Zhao, Y.4    Nelson, J.S.5    Chen, Z.6
  • 5
    • 0042810881 scopus 로고    scopus 로고
    • Determination of flow velocity vector based on Doppler shift and spectrum broadening with optical coherence tomography
    • Proskurin, S. G., He, Y. and Wang, R. K., "Determination of flow velocity vector based on Doppler shift and spectrum broadening with optical coherence tomography," Opt. Lett. 28, 1227-1229 (2003).
    • (2003) Opt. Lett , vol.28 , pp. 1227-1229
    • Proskurin, S.G.1    He, Y.2    Wang, R.K.3
  • 6
    • 41849148297 scopus 로고    scopus 로고
    • A zero-crossing detection method applied to Doppler OCT
    • Xu, Z., Carrion, L. and Maciejko, R., "A zero-crossing detection method applied to Doppler OCT, " Opt. Express 16, 4394-4412 (2008).
    • (2008) Opt. Express , vol.16 , pp. 4394-4412
    • Xu, Z.1    Carrion, L.2    Maciejko, R.3
  • 7
    • 2942733251 scopus 로고    scopus 로고
    • In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical coherence tomography
    • White, B., Pierce, M., Nassif, N., Cense, B., Park, B., Tearney, G., Bouma, B., Chen, T. and de Boer, J., "In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical coherence tomography," Opt. Express 11, 3490-3497 (2003).
    • (2003) Opt. Express , vol.11 , pp. 3490-3497
    • White, B.1    Pierce, M.2    Nassif, N.3    Cense, B.4    Park, B.5    Tearney, G.6    Bouma, B.7    Chen, T.8    de Boer, J.9
  • 8
    • 2942703836 scopus 로고    scopus 로고
    • Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography
    • Leitgeb, R., Schmetterer, L., Drexler, W., Fercher, A., Zawadzki, R. and Bajraszewski, T., "Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography," Opt. Express 11, 3116-3121 (2003).
    • (2003) Opt. Express , vol.11 , pp. 3116-3121
    • Leitgeb, R.1    Schmetterer, L.2    Drexler, W.3    Fercher, A.4    Zawadzki, R.5    Bajraszewski, T.6
  • 9
    • 36248972318 scopus 로고    scopus 로고
    • Automatic retinal blood flow calculation using spectral domain optical coherence tomography
    • Wehbe, H., Ruggeri, M., Jiao, S., Gregori, G., Puliafito, C. A. and Zhao, W., "Automatic retinal blood flow calculation using spectral domain optical coherence tomography," Opt. Express 15, 15193-15206 (2007).
    • (2007) Opt. Express , vol.15 , pp. 15193-15206
    • Wehbe, H.1    Ruggeri, M.2    Jiao, S.3    Gregori, G.4    Puliafito, C.A.5    Zhao, W.6
  • 10
    • 22744438867 scopus 로고    scopus 로고
    • Phase-resolved optical frequency domain imaging
    • Vakoc, B., Yun, S., de Boer, J., Tearney, G. and Bouma, B., "Phase-resolved optical frequency domain imaging," Opt. Express 13, 5483-5493 (2005).
    • (2005) Opt. Express , vol.13 , pp. 5483-5493
    • Vakoc, B.1    Yun, S.2    de Boer, J.3    Tearney, G.4    Bouma, B.5
  • 12
    • 25144461753 scopus 로고    scopus 로고
    • In vivo blood flow imaging by a swept laser source based Fourier domain optical Doppler tomography
    • Zhang, J. and Chen, Z., "In vivo blood flow imaging by a swept laser source based Fourier domain optical Doppler tomography," Opt. Express 13, 7449-7457 (2005).
    • (2005) Opt. Express , vol.13 , pp. 7449-7457
    • Zhang, J.1    Chen, Z.2
  • 13
    • 0000204268 scopus 로고    scopus 로고
    • Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
    • Zhao, Y., Chen, Z., Saxer, C., Xiang, S., de Boer, J. F. and Nelson, J. S., "Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity," Opt. Lett. 25, 114-116 (2000).
    • (2000) Opt. Lett , vol.25 , pp. 114-116
    • Zhao, Y.1    Chen, Z.2    Saxer, C.3    Xiang, S.4    de Boer, J.F.5    Nelson, J.S.6
  • 14
    • 65349098592 scopus 로고    scopus 로고
    • Limits of Fourier Domain Doppler-OCT at high velocities
    • Koch, E., Walther, J., Cuevas, M., "Limits of Fourier Domain Doppler-OCT at high velocities," Proc. Eurosensors XXII, p. 235 (2008).
    • (2008) Proc. Eurosensors XXII , pp. 235
    • Koch, E.1    Walther, J.2    Cuevas, M.3
  • 15
    • 22744437125 scopus 로고    scopus 로고
    • Flow measurement without phase information in optical coherence tomography images
    • Barton, J. and Stromski, S., "Flow measurement without phase information in optical coherence tomography images," Opt. Express 13, 5234-5239 (2005)
    • (2005) Opt. Express , vol.13 , pp. 5234-5239
    • Barton, J.1    Stromski, S.2
  • 17
    • 0038157635 scopus 로고    scopus 로고
    • Influence of the refractive indexmismatch at the boundaries measured in fluorescenceenhanced frequency-domain photon migration imaging
    • Godavarty, A., Hawrysz, D., Roy, R., Sevick-Muraca, E. and Eppstein, M., "Influence of the refractive indexmismatch at the boundaries measured in fluorescenceenhanced frequency-domain photon migration imaging," Opt. Express 10, 653-662 (2002).
    • (2002) Opt. Express , vol.10 , pp. 653-662
    • Godavarty, A.1    Hawrysz, D.2    Roy, R.3    Sevick-Muraca, E.4    Eppstein, M.5
  • 18
    • 5644288819 scopus 로고    scopus 로고
    • Monitoring of glycated hemoglobin by OCT measurement of refractive index
    • Tuchin, V. V., Wang, R. K., Galanzha, E. I., Elder, J. B. and Zhestkov, D. M., "Monitoring of glycated hemoglobin by OCT measurement of refractive index," Proc. SPIE 5316, 66-77 (2004).
    • (2004) Proc. SPIE , vol.5316 , pp. 66-77
    • Tuchin, V.V.1    Wang, R.K.2    Galanzha, E.I.3    Elder, J.B.4    Zhestkov, D.M.5
  • 19
    • 65349093747 scopus 로고    scopus 로고
    • Flow velocity analysis with phase-resolved Doppler Fourier Domain Optical Coherence Tomography
    • Walther, J., Mueller, G., Cuevas, M., Morawietz, H. and Koch E., "Flow velocity analysis with phase-resolved Doppler Fourier Domain Optical Coherence Tomography," Proc. Eurosensors XXII, p. 236 (2008).
    • (2008) Proc. Eurosensors XXII , pp. 236
    • Walther, J.1    Mueller, G.2    Cuevas, M.3    Morawietz, H.4    Koch, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.