메뉴 건너뛰기




Volumn 13, Issue 14, 2005, Pages 5234-5239

Flow measurement without phase information in optical coherence tomography images

Author keywords

[No Author keywords available]

Indexed keywords

COHERENT LIGHT; FLOW MEASUREMENT; IMAGE ANALYSIS; IMAGING SYSTEMS; LASER DOPPLER VELOCIMETERS; NATURAL FREQUENCIES; SPECKLE; VELOCITY MEASUREMENT;

EID: 22744437125     PISSN: 10944087     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OPEX.13.005234     Document Type: Article
Times cited : (157)

References (19)
  • 1
    • 0001226983 scopus 로고    scopus 로고
    • Optical doppler tomographic imaging of fluid flow velocity in scattering media
    • Z. Chen, T. E. Milner, D. Dave, and J. S. Nelson, "Optical Doppler Tomographic Imaging of Fluid Flow Velocity in Scattering Media," Opt. Lett. 22, 64-66 (1997).
    • (1997) Opt. Lett. , vol.22 , pp. 64-66
    • Chen, Z.1    Milner, T.E.2    Dave, D.3    Nelson, J.S.4
  • 2
    • 0000063298 scopus 로고    scopus 로고
    • In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography
    • J. A. Izatt, M. D. Kulkarni, S. Yazdanfar, J. K. Barton, and A. J. Welch, "In Vivo Bidirectional Color Doppler Flow Imaging of Picoliter Blood Volumes Using Optical Coherence Tomography," Opt. Lett. 22, 1439-1441 (1997).
    • (1997) Opt. Lett. , vol.22 , pp. 1439-1441
    • Izatt, J.A.1    Kulkarni, M.D.2    Yazdanfar, S.3    Barton, J.K.4    Welch, A.J.5
  • 3
    • 0000204268 scopus 로고    scopus 로고
    • Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
    • Y. Zhao, Z. Chen, C. Saxer, S. Xiang, J. F. de Boer, and J. S. Nelson, "Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity." Opt. Lett. 25, 114-116 (2000).
    • (2000) Opt. Lett. , vol.25 , pp. 114-116
    • Zhao, Y.1    Chen, Z.2    Saxer, C.3    Xiang, S.4    De Boer, J.F.5    Nelson, J.S.6
  • 4
    • 0037311867 scopus 로고    scopus 로고
    • In vivo imaging of human retinal flow dynamics by color Doppler optical coherence tomography
    • S. Yazdanfar, A. M. Rollins, and J. A. Izatt, "In vivo imaging of human retinal flow dynamics by color Doppler optical coherence tomography," Arch. Ophthalmol., 121, 235-239 (2003).
    • (2003) Arch. Ophthalmol. , vol.121 , pp. 235-239
    • Yazdanfar, S.1    Rollins, A.M.2    Izatt, J.A.3
  • 5
    • 0000099185 scopus 로고    scopus 로고
    • Laser Doppler and time-varying speckle: A reconciliation
    • J. D. Briers, "Laser Doppler and Time-Varying Speckle: A Reconciliation," J. Opt. Soc. Am. A, 13, 345-350 (1996).
    • (1996) J. Opt. Soc. Am. A , vol.13 , pp. 345-350
    • Briers, J.D.1
  • 6
    • 0002068881 scopus 로고
    • Statistical properties of laser speckle patterns
    • in series Topics in Applied Physics, J.C. Dainty, Ed., (Springer-Verlag, New York)
    • J.W. Goodman, "Statistical Properties of Laser Speckle Patterns," in Laser speckle and related phenomena, Vol.9 in series Topics in Applied Physics, J.C. Dainty, Ed., (Springer-Verlag, New York, 1984).
    • (1984) Laser Speckle and Related Phenomena , vol.9
    • Goodman, J.W.1
  • 7
  • 8
    • 0019579052 scopus 로고
    • Flow visualization by means of single-exposure speckle photography
    • A. F. Fercher and J. D. Briers, "Flow Visualization by Means of Single-Exposure Speckle Photography," Opt. Commun. 37, 326-330 (1981).
    • (1981) Opt. Commun. , vol.37 , pp. 326-330
    • Fercher, A.F.1    Briers, J.D.2
  • 9
    • 0000715364 scopus 로고
    • Speckle fluctuations and biomedical optics: Implications and applications
    • J. D. Briers, "Speckle Fluctuations and Biomedical Optics: Implications and Applications," Opt. Eng. 32 277-283 (1993).
    • (1993) Opt. Eng. , vol.32 , pp. 277-283
    • Briers, J.D.1
  • 10
    • 0026207688 scopus 로고
    • Bio-speckle phonomena and their application to the evaluation of blood flow
    • Y. Aizu and T. Asakura, "Bio-Speckle Phonomena and Their Application to the Evaluation of Blood Flow," Opt. Laser Tech. 23, 205-219 (1991).
    • (1991) Opt. Laser Tech. , vol.23 , pp. 205-219
    • Aizu, Y.1    Asakura, T.2
  • 11
    • 0021909491 scopus 로고
    • Blood flow observed by time-Varying laser speckle
    • H. Fujii, T. Asakura, "Blood Flow Observed by Time-Varying Laser Speckle," Opt. Int. 10, 104-106 (1985).
    • (1985) Opt. Int. , vol.10 , pp. 104-106
    • Fujii, H.1    Asakura, T.2
  • 12
    • 0141533017 scopus 로고    scopus 로고
    • Texture analysis of optical coherence tomography images: Feasibility for tissue classification
    • K. Gossage, T. Tkaczyk, J. Rodriguez and J. Barton, "Texture Analysis of Optical Coherence Tomography Images: Feasibility for Tissue Classification," J. Biomed. Opt. 8, 570-575 (2003).
    • (2003) J. Biomed. Opt. , vol.8 , pp. 570-575
    • Gossage, K.1    Tkaczyk, T.2    Rodriguez, J.3    Barton, J.4
  • 13
    • 0347764673 scopus 로고    scopus 로고
    • Time-dependent speckle in holographic optical coherence imaging and the health of tumor tissue
    • P. Yu, L. Peng, M. Mustata, "Time-dependent speckle in holographic optical coherence imaging and the health of tumor tissue," Opt. Lett. 29, 68-70 (2004).
    • (2004) Opt. Lett. , vol.29 , pp. 68-70
    • Yu, P.1    Peng, L.2    Mustata, M.3
  • 14
    • 0034992895 scopus 로고    scopus 로고
    • Photothermal coagulation of blood vessels: A comparison of high-speed optical coherence tomography and numerical modeling
    • J. K. Barton, A. S. Yazdanfar, T. J. Pfefer, V. Westphal and J. A. Izatt, "Photothermal coagulation of blood vessels: a comparison of high-speed optical coherence tomography and numerical modeling," Phys. Med. Biol. 46, 1665-1678 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1665-1678
    • Barton, J.K.1    Yazdanfar, A.S.2    Pfefer, T.J.3    Westphal, V.4    Izatt, J.A.5
  • 15
    • 0000027567 scopus 로고    scopus 로고
    • Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography
    • M. D. Kulkarni, T. G. van Leeuwen, S. Yazdanfar and J. A. Izatt, "Velocity-Estimation Accuracy and Frame-Rate limitations in Color Doppler Optical Coherence Tomography," Opt. Lett. 23, 1057-1059 (1998).
    • (1998) Opt. Lett. , vol.23 , pp. 1057-1059
    • Kulkarni, M.D.1    Van Leeuwen, T.G.2    Yazdanfar, S.3    Izatt, J.A.4
  • 16
    • 0036908776 scopus 로고    scopus 로고
    • Self-referenced doppler optical coherence tomography
    • S. Yazdanfar and J. A. Izatt, "Self-referenced Doppler optical coherence tomography," Opt. Lett. 27, 2085-2087 (2002).
    • (2002) Opt. Lett. , vol.27 , pp. 2085-2087
    • Yazdanfar, S.1    Izatt, J.A.2
  • 19
    • 0036400181 scopus 로고    scopus 로고
    • Speckle image properties in optical coherence tomography
    • T. S. Tkaczyk, K. W. Gossage and J. K. Barton, "Speckle Image Properties in Optical Coherence Tomography," Proc. SPIE 4619, 59-77 (2002).
    • (2002) Proc. SPIE , vol.4619 , pp. 59-77
    • Tkaczyk, T.S.1    Gossage, K.W.2    Barton, J.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.