메뉴 건너뛰기




Volumn 30, Issue 4, 2009, Pages 346-352

Suture-button versus screw fixation in a syndesmosis rupture model: A biomechanical comparison

Author keywords

Ankle; Flexible; Suture button; Syndesmosis; Tibiofibular

Indexed keywords

ANKLE INJURY; ARTICLE; FRACTURE FIXATION; HUMAN; INTERMETHOD COMPARISON; JOINT FUNCTION; JOINT MOBILITY; POSTERIOR LONGITUDINAL LIGAMENT; PRIORITY JOURNAL; SUTURING METHOD;

EID: 65249170168     PISSN: 10711007     EISSN: None     Source Type: Journal    
DOI: 10.3113/FAI.2009.0346     Document Type: Article
Times cited : (79)

References (17)
  • 1
    • 0346873927 scopus 로고    scopus 로고
    • Anatomy of the tibiofibular syndesmosis and its clinical relevance
    • Bartonicek, J: Anatomy of the tibiofibular syndesmosis and its clinical relevance. Surg. Radiol. Anat. 25(5-6):379-386, 2003. http://dx.doi.org/10.1007/s00276-003-0156-4
    • (2003) Surg. Radiol. Anat , vol.25 , Issue.5-6 , pp. 379-386
    • Bartonicek, J.1
  • 2
    • 10044268577 scopus 로고    scopus 로고
    • Screw fixation of the syndesmosis: A cadaver model comparing stainless steel and titanium screws and three and four cortical fixation
    • Beumer, A; Campo, MM; Niesing, R; et al.: Screw fixation of the syndesmosis: a cadaver model comparing stainless steel and titanium screws and three and four cortical fixation. Injury 36(1):60 - 64, 2005. http://dx.doi.org/10.1016/j.injury.2004.05.024
    • (2005) Injury , vol.36 , Issue.1 , pp. 60-64
    • Beumer, A.1    Campo, M.M.2    Niesing, R.3
  • 3
    • 33745579914 scopus 로고    scopus 로고
    • Effects of ligament sectioning on the kinematics of the distal tibiofibular syndesmosis. A radiostereometric study of 10 cadaveric specimens based on presumed trauma mechanisms with suggestions for treatment
    • Beumer, A; Valstar, ER; Garling, EH; et al.: Effects of ligament sectioning on the kinematics of the distal tibiofibular syndesmosis. A radiostereometric study of 10 cadaveric specimens based on presumed trauma mechanisms with suggestions for treatment. Acta Orthop. 77(3):531 -540, 2006. http://dx.doi.org/10.1080/17453670610012557
    • (2006) Acta Orthop , vol.77 , Issue.3 , pp. 531-540
    • Beumer, A.1    Valstar, E.R.2    Garling, E.H.3
  • 4
    • 27644489324 scopus 로고    scopus 로고
    • Kinematics before and after reconstruction of the anterior syndesmosis of the ankle. A prospective radiostereometric and clinical study in 5 patients
    • Beumer, A; Valstar, ER; Garling, EH; et al.: Kinematics before and after reconstruction of the anterior syndesmosis of the ankle. A prospective radiostereometric and clinical study in 5 patients. Acta Orthop. 76(5):713 - 720, 2005.
    • (2005) Acta Orthop , vol.76 , Issue.5 , pp. 713-720
    • Beumer, A.1    Valstar, E.R.2    Garling, E.H.3
  • 5
    • 0038441776 scopus 로고    scopus 로고
    • Kinematics of the distal tibiofibular syndesmosis. Radiostereometry in 11 normal ankles
    • Beumer, A; Valstar, ER; Garling, EH; et al.: Kinematics of the distal tibiofibular syndesmosis. Radiostereometry in 11 normal ankles. Acta Orthop. Scand. 74(3):337-343, 2003. http://dx.doi.org/10.1080/ 00016470310014283
    • (2003) Acta Orthop. Scand , vol.74 , Issue.3 , pp. 337-343
    • Beumer, A.1    Valstar, E.R.2    Garling, E.H.3
  • 6
    • 3042751656 scopus 로고    scopus 로고
    • Instability of the tibio-fibular syndesmosis: Have we been pulling in the wrong direction?
    • Candal-Couto, JJ; Burrow, D; Bromage, S; Briggs, PJ: Instability of the tibio-fibular syndesmosis: have we been pulling in the wrong direction? Injury 35(8):814-818, 2004. http://dx.doi.org/10.1016/j.injury.2003.10. 013
    • (2004) Injury , vol.35 , Issue.8 , pp. 814-818
    • Candal-Couto, J.J.1    Burrow, D.2    Bromage, S.3    Briggs, P.J.4
  • 7
    • 0029054345 scopus 로고
    • The influence of a diastasis screw on the outcome of Weber type-C ankle fractures
    • Chissell, HR; Jones, J: The influence of a diastasis screw on the outcome of Weber type-C ankle fractures. J. Bone Joint Surg. Br. 77(3):435-438, 1995.
    • (1995) J. Bone Joint Surg. Br , vol.77 , Issue.3 , pp. 435-438
    • Chissell, H.R.1    Jones, J.2
  • 8
    • 48349098339 scopus 로고    scopus 로고
    • Treatment of syndesmotic disruptions with the Arthrex Tightrope:a report of 25 cases
    • Cottom, JM; Hyer, CF; Philbin, TM; Berlet, GC: Treatment of syndesmotic disruptions with the Arthrex Tightrope:a report of 25 cases. Foot Ankle Int. 29(8):773-780, 2008. http://dx.doi.org/10.3113/FAI.2008.0773
    • (2008) Foot Ankle Int , vol.29 , Issue.8 , pp. 773-780
    • Cottom, J.M.1    Hyer, C.F.2    Philbin, T.M.3    Berlet, G.C.4
  • 9
    • 37849029165 scopus 로고    scopus 로고
    • Comparison of a novel FiberWire-Button construct versus metallic screw fixation in a syndesmotic injury model
    • Forsythe, K; Freedman, KB; Stover, MD; Patwardhan, AG: Comparison of a novel FiberWire-Button construct versus metallic screw fixation in a syndesmotic injury model. Foot Ankle Int. 29(1):49-54, 2008. http://dx.doi.org/10.3113/FAI.2008.0049
    • (2008) Foot Ankle Int , vol.29 , Issue.1 , pp. 49-54
    • Forsythe, K.1    Freedman, K.B.2    Stover, M.D.3    Patwardhan, A.G.4
  • 10
    • 14744282311 scopus 로고    scopus 로고
    • Comparison of the syndesmotic staple to the transsyndesmotic screw: A biomechanical study
    • Marqueen, T; Owen, J; Nicandri, G; Wayne, J; Carr, J: Comparison of the syndesmotic staple to the transsyndesmotic screw: a biomechanical study. Foot Ankle Int. 26(3):224-230, 2005.
    • (2005) Foot Ankle Int , vol.26 , Issue.3 , pp. 224-230
    • Marqueen, T.1    Owen, J.2    Nicandri, G.3    Wayne, J.4    Carr, J.5
  • 11
    • 0032621010 scopus 로고    scopus 로고
    • Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: A biomechanical study
    • Miller, RS; Weinhold, PS; Dahners, LE: Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: a biomechanical study. J. Orthop. Trauma 13(1):39-42, 1999. http://dx.doi.org/10.1097/00005131-199901000-00009
    • (1999) J. Orthop. Trauma , vol.13 , Issue.1 , pp. 39-42
    • Miller, R.S.1    Weinhold, P.S.2    Dahners, L.E.3
  • 12
    • 0020060124 scopus 로고
    • In vivo rotatory knee stability. Ligamentous and muscular contributions
    • Shoemaker, SC; Markolf, KL: In vivo rotatory knee stability. Ligamentous and muscular contributions. J. Bone Joint Surg. Am. 64(2):208-216, 1982.
    • (1982) J. Bone Joint Surg. Am , vol.64 , Issue.2 , pp. 208-216
    • Shoemaker, S.C.1    Markolf, K.L.2
  • 13
    • 35648929409 scopus 로고    scopus 로고
    • Aggressive surgical treatment and early return to sports in athletes with grade III syndesmosis sprains
    • Taylor, DC; Tenuta, JJ; Uhorchak, JM; Arciero, RA: Aggressive surgical treatment and early return to sports in athletes with grade III syndesmosis sprains. Am. J. Sports Med. 35(11):1833-1838, 2007. http://dx.doi.org/10.1177/0363546507304666
    • (2007) Am. J. Sports Med , vol.35 , Issue.11 , pp. 1833-1838
    • Taylor, D.C.1    Tenuta, J.J.2    Uhorchak, J.M.3    Arciero, R.A.4
  • 14
    • 38349149577 scopus 로고    scopus 로고
    • Three-dimensional analysis of ankle instability after tibiofibular syndesmosis injuries. A biomechanical experimental study
    • Teramoto, A; Kura, H; Uchiyama, E; Suzuki, D; Yamashita, T: Three-dimensional analysis of ankle instability after tibiofibular syndesmosis injuries. A biomechanical experimental study. Am. J. Sports Med. 36(2):348-352, 2008. http://dx.doi.org/10.1177/0363546507308235
    • (2008) Am. J. Sports Med , vol.36 , Issue.2 , pp. 348-352
    • Teramoto, A.1    Kura, H.2    Uchiyama, E.3    Suzuki, D.4    Yamashita, T.5
  • 15
    • 0037321885 scopus 로고    scopus 로고
    • Suture- endobutton fixation of ankle tibio-fibular diastasis: A cadaver study
    • Thornes, B; Walsh, A; Hislop, M; Murray, P; O'Brien, M: Suture- endobutton fixation of ankle tibio-fibular diastasis: a cadaver study. Foot Ankle Int. 24(2):142-146, 2003.
    • (2003) Foot Ankle Int , vol.24 , Issue.2 , pp. 142-146
    • Thornes, B.1    Walsh, A.2    Hislop, M.3    Murray, P.4    O'Brien, M.5
  • 16
    • 0027137191 scopus 로고
    • Knee immobilization inhibits biomechanical maturation of the rabbit medial collateral ligament
    • Walsh, S; Frank, C; Shrive, N; Hart, D: Knee immobilization inhibits biomechanical maturation of the rabbit medial collateral ligament. Clin. Orthop. Relat. Res. 297:253-261, 1993.
    • (1993) Clin. Orthop. Relat. Res , vol.297 , pp. 253-261
    • Walsh, S.1    Frank, C.2    Shrive, N.3    Hart, D.4
  • 17
    • 0028999384 scopus 로고
    • The tibiofibular syndesmosis. Evaluation of the ligamentous structures, methods of fixation, and radiographic assessment
    • Xenos, JS; Hopkinson, WJ; Mulligan, ME; Olson, EJ; Popovic, NA: The tibiofibular syndesmosis. Evaluation of the ligamentous structures, methods of fixation, and radiographic assessment. J. Bone Joint Surg. Am. 77(6):847-856, 1995.
    • (1995) J. Bone Joint Surg. Am , vol.77 , Issue.6 , pp. 847-856
    • Xenos, J.S.1    Hopkinson, W.J.2    Mulligan, M.E.3    Olson, E.J.4    Popovic, N.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.