메뉴 건너뛰기




Volumn 29, Issue 1, 2008, Pages 49-54

Comparison of a novel FiberWire-button construct versus metallic screw fixation in a syndesmotic injury model

Author keywords

[No Author keywords available]

Indexed keywords

ANKLE INJURY; ARTICLE; BIOMECHANICS; BONE SCREW; CONTROLLED STUDY; DELTOID MUSCLE; FIBULA FRACTURE; FRACTURE FIXATION; FRACTURE HEALING; HUMAN; HUMAN TISSUE; IMPLANT; LIGAMENT; PRIORITY JOURNAL; PROSTHESIS FAILURE; TIBIA;

EID: 37849029165     PISSN: 10711007     EISSN: None     Source Type: Journal    
DOI: 10.3113/FAI.2008.0049     Document Type: Article
Times cited : (106)

References (34)
  • 1
    • 0242678593 scopus 로고    scopus 로고
    • Sutures and suture anchors: Update 2003
    • Barber, FA; Herbert, MA; Richards, DP: Sutures and suture anchors: update 2003. Arthroscopy. 19:985-990, 2003. http://dx.doi.org/10.1016/j. arthro.2003.09.018.
    • (2003) Arthroscopy , vol.19 , pp. 985-990
    • Barber, F.A.1    Herbert, M.A.2    Richards, D.P.3
  • 2
    • 0024818675 scopus 로고
    • Mechanical considerations for the syndesmosis screw, a cadaver study
    • Boden SD; Labropoulos, PA; McCowin, P, et al. Mechanical considerations for the syndesmosis screw, a cadaver study. J. Bone Joint Surg. Am. 71A:1548-55, 1989.
    • (1989) J. Bone Joint Surg. Am , vol.71 A , pp. 1548-1555
    • Boden, S.D.1    Labropoulos, P.A.2    McCowin, P.3
  • 3
    • 0027510283 scopus 로고
    • Distal tibiofibular synostosis after maleolar fractures treated using absorbable implants
    • Böstman, OM: Distal tibiofibular synostosis after maleolar fractures treated using absorbable implants. Foot Ankle. 14:38-43, 1993.
    • (1993) Foot Ankle , vol.14 , pp. 38-43
    • Böstman, O.M.1
  • 4
    • 0027212810 scopus 로고    scopus 로고
    • nd; Prakash, K; Adelaar, R, et al.: Tibiotalar joint dynamics: indications for the syndesmotic screw - a cadaver study. Foot Ankle. 14:153-8, 1993.
    • nd; Prakash, K; Adelaar, R, et al.: Tibiotalar joint dynamics: indications for the syndesmotic screw - a cadaver study. Foot Ankle. 14:153-8, 1993.
  • 5
    • 0029054345 scopus 로고
    • The influence of a diastasis screw on the outcome of Weber type-C ankle fractures
    • Chissell, HR; Jones, J: The influence of a diastasis screw on the outcome of Weber type-C ankle fractures. J. Bone Joint Surg. Br. 77:435-8, 1995.
    • (1995) J. Bone Joint Surg. Br , vol.77 , pp. 435-438
    • Chissell, H.R.1    Jones, J.2
  • 6
    • 0030845399 scopus 로고    scopus 로고
    • Ankle fractures involving the fibula proximal to the distal tibiofibular syndesmosis
    • Ebraheim, NA; Mekhail, AO; Gargasz, SS: Ankle fractures involving the fibula proximal to the distal tibiofibular syndesmosis. Foot Ankle Int. 18:513-521, 1997.
    • (1997) Foot Ankle Int , vol.18 , pp. 513-521
    • Ebraheim, N.A.1    Mekhail, A.O.2    Gargasz, S.S.3
  • 7
    • 0024549801 scopus 로고
    • Early postoperative weight-bearing and muscle activity in patients who have a fracture of the ankle
    • Finsen, V; Saetermo, R; Kibsgaard, L, et al.: Early postoperative weight-bearing and muscle activity in patients who have a fracture of the ankle. J. Bone Joint Surg. Am. 71:23-27, 1989.
    • (1989) J. Bone Joint Surg. Am , vol.71 , pp. 23-27
    • Finsen, V.1    Saetermo, R.2    Kibsgaard, L.3
  • 8
    • 0023506170 scopus 로고
    • Healing of the medial collateral ligament in rats, the effects of repair, motion, and secondary stabilizing ligaments
    • Hart, DP; Dahners, LE: Healing of the medial collateral ligament in rats, the effects of repair, motion, and secondary stabilizing ligaments. J. Bone Joint Surg. Am. 69:1194-1199, 1987.
    • (1987) J. Bone Joint Surg. Am , vol.69 , pp. 1194-1199
    • Hart, D.P.1    Dahners, L.E.2
  • 10
    • 0036056819 scopus 로고    scopus 로고
    • Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation
    • Hovis, WD; Kaiser, BW; Watson JT, et al.: Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation. J. Bone Joint Surg. Am. 84:26-31, 2002.
    • (2002) J. Bone Joint Surg. Am , vol.84 , pp. 26-31
    • Hovis, W.D.1    Kaiser, B.W.2    Watson, J.T.3
  • 11
    • 84873760557 scopus 로고
    • Fractures of the ankle. II. Combined experimental-surgical and experimental-roentgenologic investigations
    • Lauge-Hansen, N: Fractures of the ankle. II. Combined experimental-surgical and experimental-roentgenologic investigations. Arch. Surg. 60:957-85, 1950.
    • (1950) Arch. Surg , vol.60 , pp. 957-985
    • Lauge-Hansen, N.1
  • 12
    • 0021248982 scopus 로고
    • Instability of the distal tibiofibular syndesmosis after bimalleolar and trimalleolar ankle fractures
    • Leeds, HC; Ehrlich, MG: Instability of the distal tibiofibular syndesmosis after bimalleolar and trimalleolar ankle fractures. J. Bone Joint Surg. Am. 66:490-503, 1984.
    • (1984) J. Bone Joint Surg. Am , vol.66 , pp. 490-503
    • Leeds, H.C.1    Ehrlich, M.G.2
  • 13
    • 0030978357 scopus 로고    scopus 로고
    • Syndesmotic screw placement: A biomechanical analysis
    • McBryde, A; Chiasson, B; Wilhelm, A et al.: Syndesmotic screw placement: a biomechanical analysis. Foot Ankle Int. 18:262-6, 1997.
    • (1997) Foot Ankle Int , vol.18 , pp. 262-266
    • McBryde, A.1    Chiasson, B.2    Wilhelm, A.3
  • 14
    • 0001259569 scopus 로고
    • Effect of embalming on the mechanical properties of beef bone
    • McElhaney, J; Fogle, J; Byars, E, et al.: Effect of embalming on the mechanical properties of beef bone. J. Appl Physiol. 19:1234-1236, 1964.
    • (1964) J. Appl Physiol , vol.19 , pp. 1234-1236
    • McElhaney, J.1    Fogle, J.2    Byars, E.3
  • 15
    • 0028822172 scopus 로고
    • Deltoid and syndesmosis ligament injury of the ankle without fracture
    • Miller, CD; Shelton, WR; Barrett, GR, et al.: Deltoid and syndesmosis ligament injury of the ankle without fracture. Am. J. Sports Med. 23:746-50, 1995. http://dx.doi.org/10.1177/036354659502300618.
    • (1995) Am. J. Sports Med , vol.23 , pp. 746-750
    • Miller, C.D.1    Shelton, W.R.2    Barrett, G.R.3
  • 16
    • 0032621010 scopus 로고    scopus 로고
    • Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: A biomechanical study
    • Miller, RS; Weinhold, PS; Dahners, LE: Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: a biomechanical study. J. Orthop. Trauma. 13:39-42, 1999. http://dx.doi.org/10.1097/00005131-199901000-00009.
    • (1999) J. Orthop. Trauma , vol.13 , pp. 39-42
    • Miller, R.S.1    Weinhold, P.S.2    Dahners, L.E.3
  • 18
    • 1242343559 scopus 로고    scopus 로고
    • Correlation of interosseous membrane tears to the level of the fibular fracture
    • Nielsen, JH; Sallis, JG; Potter, HG, et al.: Correlation of interosseous membrane tears to the level of the fibular fracture. J. Orthop. Trauma. 18(2):68-74, 2004. http://dx.doi.org/10.1097/00005131-200402000-00002.
    • (2004) J. Orthop. Trauma , vol.18 , Issue.2 , pp. 68-74
    • Nielsen, J.H.1    Sallis, J.G.2    Potter, H.G.3
  • 19
    • 0028000603 scopus 로고
    • Disruption of the ankle syndesmosis: Biomechanical study of the ligamentous restraints
    • Ogilvie-Harris, DJ; Reed, SC; Hedman, TP: Disruption of the ankle syndesmosis: biomechanical study of the ligamentous restraints. Arthroscopy. 10:558-560, 1994. http://dx.doi.org/10.1016/S0749-8063(05)80014-3
    • (1994) Arthroscopy , vol.10 , pp. 558-560
    • Ogilvie-Harris, D.J.1    Reed, S.C.2    Hedman, T.P.3
  • 20
    • 0028311659 scopus 로고
    • Biomechanical effects of internal fixation of the distal tibiofibular syndesmotic joint: Comparison of two fixation techniques
    • Peter, R E; Harrington, RM; Henley, MB, et al. Biomechanical effects of internal fixation of the distal tibiofibular syndesmotic joint: comparison of two fixation techniques. J. Orthop. Trauma. 8:215-219, 1994. http://dx.doi.org/10.1097/00005131-199406000-00006
    • (1994) J. Orthop. Trauma , vol.8 , pp. 215-219
    • Peter, R.E.1    Harrington, R.M.2    Henley, M.B.3
  • 21
    • 0020701495 scopus 로고
    • Surgical Treatment of Displaced Ankle Fractures
    • Roberts, RS: Surgical Treatment of Displaced Ankle Fractures. Clin. Orthop. 172:164-170, 1983.
    • (1983) Clin. Orthop , vol.172 , pp. 164-170
    • Roberts, R.S.1
  • 23
    • 0025983320 scopus 로고
    • Repair of the tibiofibular syndesmosis with a flexible implant
    • Seitz, WH, Jr.; Bachner, EJ; Abram, LJ, et al.: Repair of the tibiofibular syndesmosis with a flexible implant. J. Orthop Trauma. 5:78-82, 1991. http://dx.doi.org/10.1097/00005131-199103000-00014
    • (1991) J. Orthop Trauma , vol.5 , pp. 78-82
    • Seitz Jr., W.H.1    Bachner, E.J.2    Abram, L.J.3
  • 24
    • 0036677219 scopus 로고    scopus 로고
    • Ruptured tibio-fibular syndesmosis: Comparison study of metallic to bioabsorbable fixation
    • Sinisaari, IP; Luthje, PM; Mikkonen, RH: Ruptured tibio-fibular syndesmosis: comparison study of metallic to bioabsorbable fixation. Foot Ankle Int. 22:744-8, 2002.
    • (2002) Foot Ankle Int , vol.22 , pp. 744-748
    • Sinisaari, I.P.1    Luthje, P.M.2    Mikkonen, R.H.3
  • 25
    • 0028862951 scopus 로고
    • The repair of a ruptured deltoid ligament is not necessary in ankle fractures
    • Stromsoe, K; Hogeveld, HE; Skjedal, S; Alho, A: The repair of a ruptured deltoid ligament is not necessary in ankle fractures. J. Bone Joint Surg-B. 77(6):920-1, 1995.
    • (1995) J. Bone Joint Surg-B , vol.77 , Issue.6 , pp. 920-921
    • Stromsoe, K.1    Hogeveld, H.E.2    Skjedal, S.3    Alho, A.4
  • 26
    • 0033623160 scopus 로고    scopus 로고
    • Biomechanical comparison of syndesmosis fixation with 3.5- and 4.5-millimeter stainless steel screws
    • Thompson, MC; Gesink, DS: Biomechanical comparison of syndesmosis fixation with 3.5- and 4.5-millimeter stainless steel screws. Foot Ankle Int. 21:736-741, 2000.
    • (2000) Foot Ankle Int , vol.21 , pp. 736-741
    • Thompson, M.C.1    Gesink, D.S.2
  • 27
    • 0030771112 scopus 로고    scopus 로고
    • Biomechanical evaluation of polylactide absorbable screws used for syndesmosis injury repair
    • Thordarson, DB; Hedman, TP; Gross, D, et al: Biomechanical evaluation of polylactide absorbable screws used for syndesmosis injury repair. Foot Ankle Int. 18:622-627, 1997.
    • (1997) Foot Ankle Int , vol.18 , pp. 622-627
    • Thordarson, D.B.1    Hedman, T.P.2    Gross, D.3
  • 28
    • 0037321885 scopus 로고    scopus 로고
    • Suture-endobutton fixation of ankle tibio-fibular diastasis: A cadaver study
    • Thornes, B; Walsh, A; Hislop, M, et al.: Suture-endobutton fixation of ankle tibio-fibular diastasis: a cadaver study. Foot Ankle Int. 24:142-6, 2003.
    • (2003) Foot Ankle Int , vol.24 , pp. 142-146
    • Thornes, B.1    Walsh, A.2    Hislop, M.3
  • 29
    • 13244258424 scopus 로고    scopus 로고
    • Suture-button syndesmosis fixation: Accelerated rehabilitation and improved outcomes
    • Thornes, B; Shannon, F; Guiney, AM, et al.: Suture-button syndesmosis fixation: accelerated rehabilitation and improved outcomes. Clin. Orthop. 431;207-212, 2005.
    • (2005) Clin. Orthop , vol.431 , pp. 207-212
    • Thornes, B.1    Shannon, F.2    Guiney, A.M.3
  • 30
    • 85130081949 scopus 로고    scopus 로고
    • rd; Spoo, JE; Reynolds, FA, et al.: Overtightening of the ankle syndesmosis: is it really possible? J. Bone Joint Surg. Am. 83:489-492, 2001.
    • rd; Spoo, JE; Reynolds, FA, et al.: Overtightening of the ankle syndesmosis: is it really possible? J. Bone Joint Surg. Am. 83:489-492, 2001.
  • 31
    • 0029980856 scopus 로고    scopus 로고
    • Postoperative treatment of internally fixed ankle fractures, a prospective randomised study
    • van Laarhoven, CJ; Meeuwis, JD; van der Werken, C: Postoperative treatment of internally fixed ankle fractures, a prospective randomised study. J Bone Joint Surg. Br. 78:395-399, 1996.
    • (1996) J Bone Joint Surg. Br , vol.78 , pp. 395-399
    • van Laarhoven, C.J.1    Meeuwis, J.D.2    van der Werken, C.3
  • 32
    • 0027137191 scopus 로고
    • Knee i mmobilization inhibits biomechanical maturation of the rabbit medial collateral ligament
    • Walsh, S; Frank, C; Srive, N et al.: Knee i mmobilization inhibits biomechanical maturation of the rabbit medial collateral ligament. Clin. Orthop. 297:253-261, 1993.
    • (1993) Clin. Orthop , vol.297 , pp. 253-261
    • Walsh, S.1    Frank, C.2    Srive, N.3
  • 33
    • 0028999384 scopus 로고
    • The tibiofibular syndesmosis, evaluation of the ligamentous structures, methods of fixation, and radiographic assessment
    • Xenos, JS; Hopkinson, WJ; Mulligan, ME, et al.: The tibiofibular syndesmosis, evaluation of the ligamentous structures, methods of fixation, and radiographic assessment. J. Bone Joint Surg. Am. 77:847-856, 1995.
    • (1995) J. Bone Joint Surg. Am , vol.77 , pp. 847-856
    • Xenos, J.S.1    Hopkinson, W.J.2    Mulligan, M.E.3
  • 34
    • 0027966963 scopus 로고
    • Operative treatment of syndesmotic disruptions without use of a syndesmotic screw: A prospective clinical study
    • Yamaguchi, K; Martin, CH; Boden, SD, et al.: Operative treatment of syndesmotic disruptions without use of a syndesmotic screw: a prospective clinical study. Foot Ankle Int. 15:407-414, 1994.
    • (1994) Foot Ankle Int , vol.15 , pp. 407-414
    • Yamaguchi, K.1    Martin, C.H.2    Boden, S.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.