메뉴 건너뛰기




Volumn 7, Issue 3, 2008, Pages 196-202

Treatment of syndesmosis disruptions with TightRope fixation

Author keywords

Ankle biomechanics; Syndesmosis injuries; TightRope fixation; Weber C fractures

Indexed keywords

ANATOMY; ANKLE FRACTURE; ANKLE SYNDESMOSIS DISRUPTION; ARTICLE; BIOMECHANICS; CAST APPLICATION; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; FIXATION DEVICE; HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RANGE OF MOTION; SPLINT; SURGICAL INJURY; SURGICAL TECHNIQUE; TREATMENT CONTRAINDICATION; TREATMENT INDICATION; TREATMENT OUTCOME;

EID: 65249094666     PISSN: 15360644     EISSN: 15381943     Source Type: Journal    
DOI: 10.1097/BTF.0b013e3181757476     Document Type: Article
Times cited : (41)

References (19)
  • 1
    • 0028000603 scopus 로고
    • Disruption of the ankle syndesmosis: Biomechanical study of the ligamentous restraints
    • Ogilvie-Harris DJ, Reed SC, Hedman TP. Disruption of the ankle syndesmosis: biomechanical study of the ligamentous restraints. Arthroscopy. 1994;10:558-560.
    • (1994) Arthroscopy , vol.10 , pp. 558-560
    • Ogilvie-Harris, D.J.1    Reed, S.C.2    Hedman, T.P.3
  • 2
    • 0024333013 scopus 로고
    • Kinematics of the ankle and foot - in vivo roentgen stereophotogrammetry
    • Lundberg A. Kinematics of the ankle and foot - in vivo roentgen stereophotogrammetry. Acta Orthop Scand Suppl. 1989;223:1-24.
    • (1989) Acta Orthop Scand Suppl , vol.223 , pp. 1-24
    • Lundberg, A.1
  • 3
    • 0038441776 scopus 로고    scopus 로고
    • Kinematics of the distal tibiofibular syndesmosis. Radiostereometry in 11 normal ankles
    • Beumer A, Valstar ER, Garling EH, et al. Kinematics of the distal tibiofibular syndesmosis. Radiostereometry in 11 normal ankles. Acta Orthop Scand. 2003;74:337-343.
    • (2003) Acta Orthop Scand , vol.74 , pp. 337-343
    • Beumer, A.1    Valstar, E.R.2    Garling, E.H.3
  • 4
    • 33749338138 scopus 로고    scopus 로고
    • Revisiting the concept of talar shift in ankle fractures
    • Lloyd J, Elsayed S, Hariharan K, et al. Revisiting the concept of talar shift in ankle fractures. Foot Ankle Int. 2006;27:793-796.
    • (2006) Foot Ankle Int , vol.27 , pp. 793-796
    • Lloyd, J.1    Elsayed, S.2    Hariharan, K.3
  • 5
    • 0017233865 scopus 로고
    • Changes in tibiotalar area of contact caused by lateral talar shift
    • Ramsey PL, Hamilton W. Changes in tibiotalar area of contact caused by lateral talar shift. J Bone Joint Surg Am. 1976;58:356-357.
    • (1976) J Bone Joint Surg Am , vol.58 , pp. 356-357
    • Ramsey, P.L.1    Hamilton, W.2
  • 6
    • 33750681998 scopus 로고    scopus 로고
    • Three-dimensional volume rendering of tibiofibular joint space and quantitative analysis of change in volume due to tibiofibular syndesmosis diastases
    • Epub March 15
    • Taser F, Shafiq Q, Ebraheim NA. Three-dimensional volume rendering of tibiofibular joint space and quantitative analysis of change in volume due to tibiofibular syndesmosis diastases. Skeletal Radiol. 2006;35:935-941. Epub March 15, 2006.
    • (2006) Skeletal Radiol. 2006 , vol.35 , pp. 935-941
    • Taser, F.1    Shafiq, Q.2    Ebraheim, N.A.3
  • 7
    • 0035067152 scopus 로고    scopus 로고
    • Overtightening of the ankle syndesmosis: Is it really possible?
    • Tornetta P, Spoo JE, Reynolds FA, et al. Overtightening of the ankle syndesmosis: is it really possible? J Bone Joint Surg Am. 2001;83-A:489-492.
    • (2001) J Bone Joint Surg Am , vol.83-A , pp. 489-492
    • Tornetta, P.1    Spoo, J.E.2    Reynolds, F.A.3
  • 8
    • 0030978357 scopus 로고    scopus 로고
    • Syndesmotic screw placement: A biomechanical analysis
    • McBryde A, Chiasson B, Wilhelm A, et al. Syndesmotic screw placement: a biomechanical analysis. Foot Ankle Int. 1997;18:262-266.
    • (1997) Foot Ankle Int , vol.18 , pp. 262-266
    • McBryde, A.1    Chiasson, B.2    Wilhelm, A.3
  • 9
    • 0033623160 scopus 로고    scopus 로고
    • Biomechanical comparison of syndesmosis fixation with 3.5 and 4.5-millimeter stainless steel screws
    • Thompson MC, Gesink DS. Biomechanical comparison of syndesmosis fixation with 3.5 and 4.5-millimeter stainless steel screws. Foot Ankle Int. 2000;21:736-741.
    • (2000) Foot Ankle Int , vol.21 , pp. 736-741
    • Thompson, M.C.1    Gesink, D.S.2
  • 10
    • 4043151571 scopus 로고    scopus 로고
    • Tricortical versus quadricortical syndesmosis fixation in ankle fractures. A prospective, randomized study comparing two methods of syndesmosis fixation
    • Hoiness P, Stromsoe K. Tricortical versus quadricortical syndesmosis fixation in ankle fractures. A prospective, randomized study comparing two methods of syndesmosis fixation. J Orthop Trauma. 2004;18:331-337.
    • (2004) J Orthop Trauma , vol.18 , pp. 331-337
    • Hoiness, P.1    Stromsoe, K.2
  • 11
    • 10044268577 scopus 로고    scopus 로고
    • Screw fixation of the syndesmosis: A cadaver model comparing stainless steel and titanium screws and three and four cortical fixation
    • Beumer A, Campo MM, Niesing R, et al. Screw fixation of the syndesmosis: a cadaver model comparing stainless steel and titanium screws and three and four cortical fixation. Injury. 2005;36:60-64.
    • (2005) Injury , vol.36 , pp. 60-64
    • Beumer, A.1    Campo, M.M.2    Niesing, R.3
  • 12
    • 33749338139 scopus 로고    scopus 로고
    • Malreduction of the tibiofibular syndesmosis in ankle fractures
    • Gardner MJ, Demetrakopoulos D, Briggs SM, et al. Malreduction of the tibiofibular syndesmosis in ankle fractures. Foot Ankle Int. 2006;27:788-792.
    • (2006) Foot Ankle Int , vol.27 , pp. 788-792
    • Gardner, M.J.1    Demetrakopoulos, D.2    Briggs, S.M.3
  • 13
    • 14844330683 scopus 로고    scopus 로고
    • Predictors of functional outcome following transsyndesmotic screw fixation of ankle fractures
    • Weening B, Bhandari M. Predictors of functional outcome following transsyndesmotic screw fixation of ankle fractures. J Orthop Trauma. 2005;19:102-108.
    • (2005) J Orthop Trauma , vol.19 , pp. 102-108
    • Weening, B.1    Bhandari, M.2
  • 14
    • 0031916340 scopus 로고    scopus 로고
    • Clinical tests for ankle syndesmosis injury: Reliability and prediction of return to function
    • Alonso A, Khoury L, Adams R. Clinical tests for ankle syndesmosis injury: reliability and prediction of return to function. JOSPT. 1998;27:276-284.
    • (1998) JOSPT , vol.27 , pp. 276-284
    • Alonso, A.1    Khoury, L.2    Adams, R.3
  • 15
    • 14844364008 scopus 로고    scopus 로고
    • The crossed-leg test for examination of ankle syndesmosis injuries
    • Kiter E, Bozkurt M. The crossed-leg test for examination of ankle syndesmosis injuries. Foot Ankle Int. 2005;19:187-492.
    • (2005) Foot Ankle Int , vol.19 , pp. 187-492
    • Kiter, E.1    Bozkurt, M.2
  • 16
    • 0031595856 scopus 로고    scopus 로고
    • A biomechanical analysis of the squeeze test for sprains of the syndesmotic ligaments of the ankle
    • Teitz CC, Harrington RM. A biomechanical analysis of the squeeze test for sprains of the syndesmotic ligaments of the ankle. Foot Ankle Int. 1998;19:489-492.
    • (1998) Foot Ankle Int , vol.19 , pp. 489-492
    • Teitz, C.C.1    Harrington, R.M.2
  • 17
    • 13244258424 scopus 로고    scopus 로고
    • Suture-button syndesmosis fixation: Accelerated rehabilitation and improved outcomes
    • Thornes B, Shannon F, Guiney A, et al. Suture-button syndesmosis fixation: accelerated rehabilitation and improved outcomes. Clin Orthop. 2005;431:207-212.
    • (2005) Clin Orthop , vol.431 , pp. 207-212
    • Thornes, B.1    Shannon, F.2    Guiney, A.3
  • 18
    • 0032621010 scopus 로고    scopus 로고
    • Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: A biomechanical study
    • Miller R, Weinhold P, Dahners L. Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: a biomechanical study. J Orthop Trauma. 1999;13:39-42.
    • (1999) J Orthop Trauma , vol.13 , pp. 39-42
    • Miller, R.1    Weinhold, P.2    Dahners, L.3
  • 19
    • 37849029165 scopus 로고    scopus 로고
    • Comparison of a novel fiberwire-button construct versus metallic screw fixation is a syndesmotic injury model
    • Forsythe K, Freedman K, Stover M, et al. Comparison of a novel fiberwire-button construct versus metallic screw fixation is a syndesmotic injury model. Foot Ankle Int. 2008;29:49-54.
    • (2008) Foot Ankle Int , vol.29 , pp. 49-54
    • Forsythe, K.1    Freedman, K.2    Stover, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.