-
1
-
-
65149105368
-
Primary discussion on prerequisites to noninvasive blood glucose
-
LI Qing-Bo, XU Ke-Xin, WANG Yan. Primary discussion on prerequisites to noninvasive blood glucose[J]. Journal of Tianjin University, 2003, 36(2): 139-142.
-
(2003)
Journal of Tianjin University
, vol.36
, Issue.2
, pp. 139-142
-
-
Li, Q.-B.1
Xu, K.-X.2
Wang, Y.3
-
2
-
-
33845517523
-
Theoretic study on improving noninvasive measurement accuracy of blood component by dynamic spectrum method
-
LI Gang, WANG Yan, LI Qiu-Xia, et al. Theoretic study on improving noninvasive measurement accuracy of blood component by dynamic spectrum method[J]. J. Infrared Millime. Waves, 2006, 25(5): 345-348.
-
(2006)
J. Infrared Millime. Waves
, vol.25
, Issue.5
, pp. 345-348
-
-
Li, G.1
Wang, Y.2
Li, Q.-X.3
-
3
-
-
34548630504
-
Application of digital fourier filtering pretreatment method to improving robustness of multivariate calibration model in near infrared spectroscopy
-
LI Qing-Bo, ZHANG Guang-Jun, XU Ke-Xin, et al. Application of digital fourier filtering pretreatment method to improving robustness of multivariate calibration model in near infrared spectroscopy[J]. Spectroscopy and Spectral Analysis, 2007, 27(8): 1484-1488.
-
(2007)
Spectroscopy and Spectral Analysis
, vol.27
, Issue.8
, pp. 1484-1488
-
-
Li, Q.-B.1
Zhang, G.-J.2
Xu, K.-X.3
-
4
-
-
43749108447
-
Analysis of soluble solid content in Nanfeng mandarin fruit with visible near infrared spectroscopy
-
LIU Yan-De, LUO Ji, CHEN Xing-Miao. Analysis of soluble solid content in Nanfeng mandarin fruit with visible near infrared spectroscopy[J]. J. Infrared Millim. Waves, 2008, 27(2): 119-122.
-
(2008)
J. Infrared Millim. Waves
, vol.27
, Issue.2
, pp. 119-122
-
-
Liu, Y.-D.1
Luo, J.2
Chen, X.-M.3
-
5
-
-
43749112240
-
Rapid detection method of the spicy components in zanthoxylum bungeagum maxim by near infrared spectroscopy
-
ZHU Shi-Ping, WANG Gang, YANG Fei, et al. Rapid detection method of the spicy components in zanthoxylum bungeagum maxim by near infrared spectroscopy[J]. J. Infrared Millim. Waves, 2008, 27(2): 129-132.
-
(2008)
J. Infrared Millim. Waves
, vol.27
, Issue.2
, pp. 129-132
-
-
Zhu, S.-P.1
Wang, G.2
Yang, F.3
-
6
-
-
2342631974
-
A Background noise elimination method for quantitative calibration of near infrared spectra
-
Chen Da, Shao Xueguang, Hu Bin, et al. A Background noise elimination method for quantitative calibration of near infrared spectra[J]. Analytica Chimica Acta, 2004, 511(1): 37-45.
-
(2004)
Analytica Chimica Acta
, vol.511
, Issue.1
, pp. 37-45
-
-
Chen, D.1
Shao, X.2
Hu, B.3
-
7
-
-
0036080094
-
Wavelet analysis applied to removing non-constant varying spectroscopic background in multivariate calibration
-
Tan Hu-Wei, Brown S D. Wavelet analysis applied to removing non-constant varying spectroscopic background in multivariate calibration[J]. Journal of Chemometrics, 2002, 16(5): 228-240.
-
(2002)
Journal of Chemometrics
, vol.16
, Issue.5
, pp. 228-240
-
-
Tan, H.-W.1
Brown, S.D.2
-
8
-
-
0000105237
-
Elimination of uninformative variables for multivariate calibration
-
Centner V, Massart D L, De Noord O E, et al. Elimination of uninformative variables for multivariate calibration[J]. Analytical chemistry, 1996, 68(21): 3851-3858.
-
(1996)
Analytical Chemistry
, vol.68
, Issue.21
, pp. 3851-3858
-
-
Centner, V.1
Massart, D.L.2
de Noord, O.E.3
-
9
-
-
1542469357
-
Application of wavelet transform to extract the relevant component from spectral data for multivariate calibration
-
Jouan-Rimbaud D, Walczak B, Poppi R J, et al. Application of wavelet transform to extract the relevant component from spectral data for multivariate calibration[J]. Analytical chemistry, 1997, 69(21): 4317-4323.
-
(1997)
Analytical Chemistry
, vol.69
, Issue.21
, pp. 4317-4323
-
-
Jouan-Rimbaud, D.1
Walczak, B.2
Poppi, R.J.3
|