메뉴 건너뛰기




Volumn 28, Issue 2, 2009, Pages 107-110

Application of denoising and background elimination based on wavelet transform to blood glucose noninvasive measurement of near infrared spectroscopy

Author keywords

Background; Blood glucose noninvasive measurement; Near infrared spectroscopy; Noise; Wavelet transform

Indexed keywords

BACKGROUND; BLOOD GLUCOSE NONINVASIVE MEASUREMENT; DE-NOISING; DETAIL COEFFICIENTS; MULTI-SCALE; NEAR INFRARED SPECTRUM; NOISE; PRE-TREATMENT METHODS; PREDICTION ACCURACIES; UNINFORMATIVE VARIABLE ELIMINATIONS;

EID: 65149096768     PISSN: 10019014     EISSN: None     Source Type: Journal    
DOI: 10.3724/SP.J.1010.2009.00107     Document Type: Article
Times cited : (16)

References (9)
  • 1
    • 65149105368 scopus 로고    scopus 로고
    • Primary discussion on prerequisites to noninvasive blood glucose
    • LI Qing-Bo, XU Ke-Xin, WANG Yan. Primary discussion on prerequisites to noninvasive blood glucose[J]. Journal of Tianjin University, 2003, 36(2): 139-142.
    • (2003) Journal of Tianjin University , vol.36 , Issue.2 , pp. 139-142
    • Li, Q.-B.1    Xu, K.-X.2    Wang, Y.3
  • 2
    • 33845517523 scopus 로고    scopus 로고
    • Theoretic study on improving noninvasive measurement accuracy of blood component by dynamic spectrum method
    • LI Gang, WANG Yan, LI Qiu-Xia, et al. Theoretic study on improving noninvasive measurement accuracy of blood component by dynamic spectrum method[J]. J. Infrared Millime. Waves, 2006, 25(5): 345-348.
    • (2006) J. Infrared Millime. Waves , vol.25 , Issue.5 , pp. 345-348
    • Li, G.1    Wang, Y.2    Li, Q.-X.3
  • 3
    • 34548630504 scopus 로고    scopus 로고
    • Application of digital fourier filtering pretreatment method to improving robustness of multivariate calibration model in near infrared spectroscopy
    • LI Qing-Bo, ZHANG Guang-Jun, XU Ke-Xin, et al. Application of digital fourier filtering pretreatment method to improving robustness of multivariate calibration model in near infrared spectroscopy[J]. Spectroscopy and Spectral Analysis, 2007, 27(8): 1484-1488.
    • (2007) Spectroscopy and Spectral Analysis , vol.27 , Issue.8 , pp. 1484-1488
    • Li, Q.-B.1    Zhang, G.-J.2    Xu, K.-X.3
  • 4
    • 43749108447 scopus 로고    scopus 로고
    • Analysis of soluble solid content in Nanfeng mandarin fruit with visible near infrared spectroscopy
    • LIU Yan-De, LUO Ji, CHEN Xing-Miao. Analysis of soluble solid content in Nanfeng mandarin fruit with visible near infrared spectroscopy[J]. J. Infrared Millim. Waves, 2008, 27(2): 119-122.
    • (2008) J. Infrared Millim. Waves , vol.27 , Issue.2 , pp. 119-122
    • Liu, Y.-D.1    Luo, J.2    Chen, X.-M.3
  • 5
    • 43749112240 scopus 로고    scopus 로고
    • Rapid detection method of the spicy components in zanthoxylum bungeagum maxim by near infrared spectroscopy
    • ZHU Shi-Ping, WANG Gang, YANG Fei, et al. Rapid detection method of the spicy components in zanthoxylum bungeagum maxim by near infrared spectroscopy[J]. J. Infrared Millim. Waves, 2008, 27(2): 129-132.
    • (2008) J. Infrared Millim. Waves , vol.27 , Issue.2 , pp. 129-132
    • Zhu, S.-P.1    Wang, G.2    Yang, F.3
  • 6
    • 2342631974 scopus 로고    scopus 로고
    • A Background noise elimination method for quantitative calibration of near infrared spectra
    • Chen Da, Shao Xueguang, Hu Bin, et al. A Background noise elimination method for quantitative calibration of near infrared spectra[J]. Analytica Chimica Acta, 2004, 511(1): 37-45.
    • (2004) Analytica Chimica Acta , vol.511 , Issue.1 , pp. 37-45
    • Chen, D.1    Shao, X.2    Hu, B.3
  • 7
    • 0036080094 scopus 로고    scopus 로고
    • Wavelet analysis applied to removing non-constant varying spectroscopic background in multivariate calibration
    • Tan Hu-Wei, Brown S D. Wavelet analysis applied to removing non-constant varying spectroscopic background in multivariate calibration[J]. Journal of Chemometrics, 2002, 16(5): 228-240.
    • (2002) Journal of Chemometrics , vol.16 , Issue.5 , pp. 228-240
    • Tan, H.-W.1    Brown, S.D.2
  • 8
    • 0000105237 scopus 로고    scopus 로고
    • Elimination of uninformative variables for multivariate calibration
    • Centner V, Massart D L, De Noord O E, et al. Elimination of uninformative variables for multivariate calibration[J]. Analytical chemistry, 1996, 68(21): 3851-3858.
    • (1996) Analytical Chemistry , vol.68 , Issue.21 , pp. 3851-3858
    • Centner, V.1    Massart, D.L.2    de Noord, O.E.3
  • 9
    • 1542469357 scopus 로고    scopus 로고
    • Application of wavelet transform to extract the relevant component from spectral data for multivariate calibration
    • Jouan-Rimbaud D, Walczak B, Poppi R J, et al. Application of wavelet transform to extract the relevant component from spectral data for multivariate calibration[J]. Analytical chemistry, 1997, 69(21): 4317-4323.
    • (1997) Analytical Chemistry , vol.69 , Issue.21 , pp. 4317-4323
    • Jouan-Rimbaud, D.1    Walczak, B.2    Poppi, R.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.