메뉴 건너뛰기




Volumn 20, Issue 1, 2009, Pages 111-118

Fourier-domain optical coherence tomography: recent advances toward clinical utility

Author keywords

[No Author keywords available]

Indexed keywords

CLINICAL STUDIES; CLINICAL UTILITIES; FOURIER DOMAINS; FOURIER-DOMAIN OCT; FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHIES; HIGH RESOLUTIONS; INTERNAL ORGANS; MICROSCOPIC IMAGING; MINIMALLY INVASIVE; OPTICAL-COHERENCE TOMOGRAPHIES; THREE-DIMENSIONAL VOLUMES;

EID: 65149088629     PISSN: 09581669     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.copbio.2009.02.007     Document Type: Review
Times cited : (91)

References (81)
  • 4
    • 84975568379 scopus 로고
    • New measurement system for fault location in optical waveguide devices based on interferometric technique
    • Takada K., Yokohama I., Chida K., and Noda J. New measurement system for fault location in optical waveguide devices based on interferometric technique. Appl Opt 26 (1987) 1603-1606
    • (1987) Appl Opt , vol.26 , pp. 1603-1606
    • Takada, K.1    Yokohama, I.2    Chida, K.3    Noda, J.4
  • 5
    • 0023136979 scopus 로고
    • Optical coherence domain reflectometry: a new optical evaluation technique
    • Youngquist R.C., Carr S., and Davies D.E.N. Optical coherence domain reflectometry: a new optical evaluation technique. Opt Lett 12 (1987) 158-160
    • (1987) Opt Lett , vol.12 , pp. 158-160
    • Youngquist, R.C.1    Carr, S.2    Davies, D.E.N.3
  • 6
    • 84975538971 scopus 로고
    • Eye-length measurement by interferometry with partially coherent-light
    • Fercher A.F., Mengedoht K., and Werner W. Eye-length measurement by interferometry with partially coherent-light. Opt Lett 13 (1988) 186-188
    • (1988) Opt Lett , vol.13 , pp. 186-188
    • Fercher, A.F.1    Mengedoht, K.2    Werner, W.3
  • 8
    • 0000950973 scopus 로고    scopus 로고
    • Self-phase-modulated kerr-lens mode-locked cr:Forsterite laser source for optical coherence tomography
    • Bouma B.E., Tearney G.J., Bilinsky I.P., Golubovic B., and Fujimoto J.G. Self-phase-modulated kerr-lens mode-locked cr:Forsterite laser source for optical coherence tomography. Opt Lett 21 (1996) 1839-1841
    • (1996) Opt Lett , vol.21 , pp. 1839-1841
    • Bouma, B.E.1    Tearney, G.J.2    Bilinsky, I.P.3    Golubovic, B.4    Fujimoto, J.G.5
  • 10
    • 5244345537 scopus 로고    scopus 로고
    • High-speed phase- and group-delay scanning with a grating-based phase control delay line
    • Tearney G.J., Bouma B.E., and Fujimoto J.G. High-speed phase- and group-delay scanning with a grating-based phase control delay line. Opt Lett 22 (1997) 1811-1813
    • (1997) Opt Lett , vol.22 , pp. 1811-1813
    • Tearney, G.J.1    Bouma, B.E.2    Fujimoto, J.G.3
  • 12
    • 0027934282 scopus 로고
    • Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering
    • Schmitt J.M., Knuttel A., Yadlowsky M., and Eckhaus M.A. Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering. Phys Med Biol 39 (1994) 1705-1720
    • (1994) Phys Med Biol , vol.39 , pp. 1705-1720
    • Schmitt, J.M.1    Knuttel, A.2    Yadlowsky, M.3    Eckhaus, M.A.4
  • 13
    • 0032620384 scopus 로고    scopus 로고
    • Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography
    • Bouma B.E., and Tearney G.J. Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography. Opt Lett 24 (1999) 531-533
    • (1999) Opt Lett , vol.24 , pp. 531-533
    • Bouma, B.E.1    Tearney, G.J.2
  • 17
    • 0034072983 scopus 로고    scopus 로고
    • High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography
    • Bouma B.E., Tearney G.J., Compton C.C., and Nishioka N.S. High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography. Gastrointest Endosc 51 (2000) 467-474
    • (2000) Gastrointest Endosc , vol.51 , pp. 467-474
    • Bouma, B.E.1    Tearney, G.J.2    Compton, C.C.3    Nishioka, N.S.4
  • 21
    • 2942538290 scopus 로고    scopus 로고
    • Diagnostic efficacy of optical coherence tomography in the management of preinvasive and invasive cancer of uterine cervix and vulva
    • Escobar P.F., Belinson J.L., White A., Shakhova N.M., Feldchtein F.I., Kareta M.V., and Gladkova N.D. Diagnostic efficacy of optical coherence tomography in the management of preinvasive and invasive cancer of uterine cervix and vulva. Int J Gynecol Cancer 14 (2004) 470-474
    • (2004) Int J Gynecol Cancer , vol.14 , pp. 470-474
    • Escobar, P.F.1    Belinson, J.L.2    White, A.3    Shakhova, N.M.4    Feldchtein, F.I.5    Kareta, M.V.6    Gladkova, N.D.7
  • 22
    • 50249171693 scopus 로고    scopus 로고
    • Visualization of the basement membrane zone of the bladder by optical coherence tomography: feasibility of noninvasive evaluation of tumor invasion
    • Hermes B., Spoler F., Naami A., Bornemann J., Forst M., Grosse J., Jakse G., and Knuchel R. Visualization of the basement membrane zone of the bladder by optical coherence tomography: feasibility of noninvasive evaluation of tumor invasion. Urology 72 (2008) 677-681
    • (2008) Urology , vol.72 , pp. 677-681
    • Hermes, B.1    Spoler, F.2    Naami, A.3    Bornemann, J.4    Forst, M.5    Grosse, J.6    Jakse, G.7    Knuchel, R.8
  • 25
    • 0035960591 scopus 로고    scopus 로고
    • Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: comparison with intravascular ultrasound
    • Jang I.-K., Tearney G.J., and Bouma B.E. Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: comparison with intravascular ultrasound. Circulation 104 (2001) 2754
    • (2001) Circulation , vol.104 , pp. 2754
    • Jang, I.-K.1    Tearney, G.J.2    Bouma, B.E.3
  • 26
    • 0037195157 scopus 로고    scopus 로고
    • Intracoronary imaging with optical coherence tomography-a new high-resolution technology providing striking visualization in the coronary artery
    • Grube E., Gerckens U., Buellesfeld L., and Fitzgerald P.J. Intracoronary imaging with optical coherence tomography-a new high-resolution technology providing striking visualization in the coronary artery. Circulation 106 (2002) 2409-2410
    • (2002) Circulation , vol.106 , pp. 2409-2410
    • Grube, E.1    Gerckens, U.2    Buellesfeld, L.3    Fitzgerald, P.J.4
  • 28
    • 33644874009 scopus 로고    scopus 로고
    • Optical coherence tomography findings at 5-year follow-up after coronary stent implantation
    • Regar E., van Beusekom H.M.M., van der Giessen W.J., and Serruys P.W. Optical coherence tomography findings at 5-year follow-up after coronary stent implantation. Circulation 112 (2005) E345-E346
    • (2005) Circulation , vol.112
    • Regar, E.1    van Beusekom, H.M.M.2    van der Giessen, W.J.3    Serruys, P.W.4
  • 30
    • 49349089984 scopus 로고    scopus 로고
    • Frequency and predictor of coronary thin-cap fibroatheroma in patients with acute myocardial infarction and stable angina pectoris a 3-vessel optical coherence tomography study
    • Fujii K., Masutani M., Okumura T., Kawasaki D., Akagami T., Ezumi A., Sakoda T., Masuyama T., and Ohyanagi M. Frequency and predictor of coronary thin-cap fibroatheroma in patients with acute myocardial infarction and stable angina pectoris a 3-vessel optical coherence tomography study. J Am Coll Cardiol 52 (2008) 787-788
    • (2008) J Am Coll Cardiol , vol.52 , pp. 787-788
    • Fujii, K.1    Masutani, M.2    Okumura, T.3    Kawasaki, D.4    Akagami, T.5    Ezumi, A.6    Sakoda, T.7    Masuyama, T.8    Ohyanagi, M.9
  • 31
    • 50849143477 scopus 로고    scopus 로고
    • Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting
    • Guagliumi G., and Sirbu V. Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72 (2008) 237-247
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 237-247
    • Guagliumi, G.1    Sirbu, V.2
  • 32
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and fourier domain optical coherence tomography
    • •], this manuscript provided a comprehensive theoretical analysis demonstrating the improvement in signal detection sensitivity provided by Fourier-domain OCT relative to time-domain OCT.
    • •], this manuscript provided a comprehensive theoretical analysis demonstrating the improvement in signal detection sensitivity provided by Fourier-domain OCT relative to time-domain OCT.
    • (2003) Opt Exp , vol.11 , pp. 2183-2189
    • Choma, M.1    Sarunic, M.2    Yang, C.3    Izatt, J.4
  • 33
    • 0242301675 scopus 로고    scopus 로고
    • Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    • •], this manuscript provided a comprehensive theoretical analysis demonstrating the improvement in signal detection sensitivity provided by Fourier-domain OCT relative to time-domain OCT.
    • •], this manuscript provided a comprehensive theoretical analysis demonstrating the improvement in signal detection sensitivity provided by Fourier-domain OCT relative to time-domain OCT.
    • (2003) Opt Lett , vol.28 , pp. 2067-2069
    • de Boer, J.F.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Tearney, G.J.5    Bouma, B.E.6
  • 34
    • 0038618462 scopus 로고    scopus 로고
    • Performance of fourier domain vs. Time domain optical coherence tomography
    • •], this manuscript provided a comprehensive theoretical analysis demonstrating the improvement in signal detection sensitivity provided by Fourier-domain OCT relative to time-domain OCT.
    • •], this manuscript provided a comprehensive theoretical analysis demonstrating the improvement in signal detection sensitivity provided by Fourier-domain OCT relative to time-domain OCT.
    • (2003) Opt. Express , vol.11 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.2    Fercher, A.3
  • 35
    • 0141928808 scopus 로고    scopus 로고
    • Real-time in vivo imaging by high-speed spectral optical coherence tomography
    • The authors describe the use of spectral-domain OCT for acquiring individual axial scans in 64 μs and confirm the ability to preserve high-resolution and deep imaging penetration.
    • Wojtkowski M., Bajraszewski T., Targowski P., and Kowalczyk A. Real-time in vivo imaging by high-speed spectral optical coherence tomography. Opt Lett 28 (2003) 1745-1747. The authors describe the use of spectral-domain OCT for acquiring individual axial scans in 64 μs and confirm the ability to preserve high-resolution and deep imaging penetration.
    • (2003) Opt Lett , vol.28 , pp. 1745-1747
    • Wojtkowski, M.1    Bajraszewski, T.2    Targowski, P.3    Kowalczyk, A.4
  • 36
    • 2942715001 scopus 로고    scopus 로고
    • High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength
    • Yun S.H., Tearney G.J., Bouma B.E., Park B.H., and de Boer J.F. High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength. Opt Exp 11 (2003) 3598-3604
    • (2003) Opt Exp , vol.11 , pp. 3598-3604
    • Yun, S.H.1    Tearney, G.J.2    Bouma, B.E.3    Park, B.H.4    de Boer, J.F.5
  • 37
    • 2942738905 scopus 로고    scopus 로고
    • High-speed optical frequency-domain imaging
    • The authors describe the first high-speed frequency-domain OCT system based on a novel wavelength swept laser source.
    • Yun S.H., Tearney G.J., de Boer J.F., Iftimia N., and Bouma B.E. High-speed optical frequency-domain imaging. Opt Exp 11 (2003) 2953-2963. The authors describe the first high-speed frequency-domain OCT system based on a novel wavelength swept laser source.
    • (2003) Opt Exp , vol.11 , pp. 2953-2963
    • Yun, S.H.1    Tearney, G.J.2    de Boer, J.F.3    Iftimia, N.4    Bouma, B.E.5
  • 38
    • 33845514512 scopus 로고    scopus 로고
    • Comprehensive volumetric optical microscopy in vivo
    • Catheter-based imaging of internal organs was demonstrated for the first time in vivo using frequency-domain OCT. The fast acquisition speed of the imaging system enabled comprehensive imaging over large segments of the esophagus and coronary arteries in swine.
    • Yun S.H., Tearney G.J., Vakoc B.J., Shishkov M., Yelin R., Oh W.Y., Desjardins A., Chan R.C., Yelin D., Evans J.A., et al. Comprehensive volumetric optical microscopy in vivo. Nat Med 12 (2006) 1429-1433. Catheter-based imaging of internal organs was demonstrated for the first time in vivo using frequency-domain OCT. The fast acquisition speed of the imaging system enabled comprehensive imaging over large segments of the esophagus and coronary arteries in swine.
    • (2006) Nat Med , vol.12 , pp. 1429-1433
    • Yun, S.H.1    Tearney, G.J.2    Vakoc, B.J.3    Shishkov, M.4    Yelin, R.5    Oh, W.Y.6    Desjardins, A.7    Chan, R.C.8    Yelin, D.9    Evans, J.A.10
  • 39
    • 0031695986 scopus 로고    scopus 로고
    • coherence radar" and 'spectral radar'-new tools for dermatological diagnosis
    • Hausler G., and Lindner M.W. coherence radar" and 'spectral radar'-new tools for dermatological diagnosis. J Biomed Opt 3 (1998) 21-31
    • (1998) J Biomed Opt , vol.3 , pp. 21-31
    • Hausler, G.1    Lindner, M.W.2
  • 40
    • 2942733251 scopus 로고    scopus 로고
    • In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical doppler tomography
    • The authors report the development of a spectral-domain OCT system capable of acquiring axial scans at a sustained rate of 29 kHz.
    • White B., Pierce M., Nassif N., Cense B., Park B., Tearney G., Bouma B., Chen T., and de Boer J. In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical doppler tomography. Opt Exp 11 (2003) 3490-3497. The authors report the development of a spectral-domain OCT system capable of acquiring axial scans at a sustained rate of 29 kHz.
    • (2003) Opt Exp , vol.11 , pp. 3490-3497
    • White, B.1    Pierce, M.2    Nassif, N.3    Cense, B.4    Park, B.5    Tearney, G.6    Bouma, B.7    Chen, T.8    de Boer, J.9
  • 41
    • 0142093656 scopus 로고    scopus 로고
    • High-speed wavelength-swept semiconductor laser with polygon-scanner-based wavelength filter
    • Yun S., Boudoux C., Tearney G., and Bouma B. High-speed wavelength-swept semiconductor laser with polygon-scanner-based wavelength filter. Opt Lett 28 (2003) 1981-1983
    • (2003) Opt Lett , vol.28 , pp. 1981-1983
    • Yun, S.1    Boudoux, C.2    Tearney, G.3    Bouma, B.4
  • 42
    • 22744455004 scopus 로고    scopus 로고
    • 115 khz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser
    • Oh W.Y., Yun S.H., Tearney G.J., and Bouma B.E. 115 khz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser. Opt Lett 30 (2005) 3159-3161
    • (2005) Opt Lett , vol.30 , pp. 3159-3161
    • Oh, W.Y.1    Yun, S.H.2    Tearney, G.J.3    Bouma, B.E.4
  • 43
    • 14844345890 scopus 로고    scopus 로고
    • Wide tuning range wavelength-swept laser with two semiconductor optical amplifiers
    • Oh W.Y., Yun S.H., Tearney G.J., and Bouma B.E. Wide tuning range wavelength-swept laser with two semiconductor optical amplifiers. Photonics Technol Lett 17 (2005) 678-680
    • (2005) Photonics Technol Lett , vol.17 , pp. 678-680
    • Oh, W.Y.1    Yun, S.H.2    Tearney, G.J.3    Bouma, B.E.4
  • 44
    • 33644919344 scopus 로고
    • Very rapid tuning of cw dye laser
    • Telle J.M., and Tang C.L. Very rapid tuning of cw dye laser. Appl Phys Lett 26 (1975) 572-574
    • (1975) Appl Phys Lett , vol.26 , pp. 572-574
    • Telle, J.M.1    Tang, C.L.2
  • 45
    • 33645820443 scopus 로고    scopus 로고
    • Fourier domain mode locking (fdml): a new laser operating regime and applications for optical coherence tomography
    • Huber R., Wojtkowski M., and Fujimoto J.G. Fourier domain mode locking (fdml): a new laser operating regime and applications for optical coherence tomography. Opt Exp 14 (2006) 3225-3237
    • (2006) Opt Exp , vol.14 , pp. 3225-3237
    • Huber, R.1    Wojtkowski, M.2    Fujimoto, J.G.3
  • 46
    • 33847612515 scopus 로고    scopus 로고
    • Phase-sensitive optical coherence tomography at up to 370 000 lines per second using buffered fourier domain mode-locked lasers
    • Using a Fourier-domain mode locked laser, wherein the wavelength filter repetition is synchronized with the laser resonator round-trip repetition, the authors demonstrate frequency-domain OCT with a depth-scanning rate of 370 kHz.
    • Adler D.C., Huber R., and Fujimoto J.G. Phase-sensitive optical coherence tomography at up to 370 000 lines per second using buffered fourier domain mode-locked lasers. Opt Lett 32 (2007) 626-628. Using a Fourier-domain mode locked laser, wherein the wavelength filter repetition is synchronized with the laser resonator round-trip repetition, the authors demonstrate frequency-domain OCT with a depth-scanning rate of 370 kHz.
    • (2007) Opt Lett , vol.32 , pp. 626-628
    • Adler, D.C.1    Huber, R.2    Fujimoto, J.G.3
  • 47
    • 9144220962 scopus 로고    scopus 로고
    • Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting
    • Yun S.H., Tearney G.J., de Boer J.F., and Bouma B.E. Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting. Opt Exp 12 (2004) 4822-4828
    • (2004) Opt Exp , vol.12 , pp. 4822-4828
    • Yun, S.H.1    Tearney, G.J.2    de Boer, J.F.3    Bouma, B.E.4
  • 48
    • 14744298997 scopus 로고    scopus 로고
    • Instantaneous complex conjugate resolved spectral domain and swept-source oct using 3 × 3 fiber couplers
    • Sarunic M.V., Choma M.A., Yang C.H., and Izatt J.A. Instantaneous complex conjugate resolved spectral domain and swept-source oct using 3 × 3 fiber couplers. Opt Exp 13 (2005) 957-967
    • (2005) Opt Exp , vol.13 , pp. 957-967
    • Sarunic, M.V.1    Choma, M.A.2    Yang, C.H.3    Izatt, J.A.4
  • 49
    • 33645079165 scopus 로고    scopus 로고
    • Elimination of depth degeneracy in optical frequency domain imaging through polarization-based optical demodulation
    • Vakoc B.J., Yun S.H., Tearney G.J., and Bouma B.E. Elimination of depth degeneracy in optical frequency domain imaging through polarization-based optical demodulation. Opt Lett 31 (2006) 362-364
    • (2006) Opt Lett , vol.31 , pp. 362-364
    • Vakoc, B.J.1    Yun, S.H.2    Tearney, G.J.3    Bouma, B.E.4
  • 50
    • 39749103540 scopus 로고    scopus 로고
    • Dynamic full-range fourier-domain optical coherence tomography using sinusoidal phase-modulating interferometry
    • Bu P., Wang X.Z., and Sasaki O. Dynamic full-range fourier-domain optical coherence tomography using sinusoidal phase-modulating interferometry. Opt Eng (2007) 46
    • (2007) Opt Eng , pp. 46
    • Bu, P.1    Wang, X.Z.2    Sasaki, O.3
  • 51
    • 33749458697 scopus 로고    scopus 로고
    • Real-time quadrature projection complex conjugate resolved fourier domain optical coherence tomography
    • Sarunic M.V., Applegate B.E., and Izatt J.A. Real-time quadrature projection complex conjugate resolved fourier domain optical coherence tomography. Opt Lett 31 (2006) 2426-2428
    • (2006) Opt Lett , vol.31 , pp. 2426-2428
    • Sarunic, M.V.1    Applegate, B.E.2    Izatt, J.A.3
  • 52
    • 38449101435 scopus 로고    scopus 로고
    • High-speed complex conjugate resolved retinal spectral domain optical coherence tomography using sinusoidal phase modulation
    • Tao Y.K., Zhao M., and Izatt J.A. High-speed complex conjugate resolved retinal spectral domain optical coherence tomography using sinusoidal phase modulation. Opt Lett 32 (2007) 2918-2920
    • (2007) Opt Lett , vol.32 , pp. 2918-2920
    • Tao, Y.K.1    Zhao, M.2    Izatt, J.A.3
  • 53
    • 40149108094 scopus 로고    scopus 로고
    • Complex ambiguity-free fourier domain optical coherence tomography through transverse scanning
    • Leitgeb R.A., Michaely R., Lasser T., and Sekhar S.C. Complex ambiguity-free fourier domain optical coherence tomography through transverse scanning. Opt Lett 32 (2007) 3453-3455
    • (2007) Opt Lett , vol.32 , pp. 3453-3455
    • Leitgeb, R.A.1    Michaely, R.2    Lasser, T.3    Sekhar, S.C.4
  • 54
    • 49949116138 scopus 로고    scopus 로고
    • 3 × 3 mach-zehnder interferometer with unbalanced differential detection for full-range swept-source optical coherence tomography
    • Mao Y.X., Sherif S., Flueraru C., and Chang S. 3 × 3 mach-zehnder interferometer with unbalanced differential detection for full-range swept-source optical coherence tomography. Appl Opt 47 (2008) 2004-2010
    • (2008) Appl Opt , vol.47 , pp. 2004-2010
    • Mao, Y.X.1    Sherif, S.2    Flueraru, C.3    Chang, S.4
  • 55
    • 53249109808 scopus 로고    scopus 로고
    • Comprehensive microscopy of the esophagus in human patients with optical frequency domain imaging
    • This manuscript describes the first use of high-speed, high-resolution Fourier-domain OCT for large area, three-dimensional imaging of the esophagus. Through the use of an endoscopic balloon probe and high-speed optical frequency domain imaging, the entire distal esophagus was imaged. The depth of imaging penetration was sufficient to visualize the full esophageal thickness.
    • Suter M.J., Vakoc B.J., Yachimski P.S., Shishkov M., Lauwers G.Y., Mino-Kenudson M., Bouma B.E., Nishioka N.S., and Tearney G.J. Comprehensive microscopy of the esophagus in human patients with optical frequency domain imaging. Gastrointest Endosc 68 (2008) 745-753. This manuscript describes the first use of high-speed, high-resolution Fourier-domain OCT for large area, three-dimensional imaging of the esophagus. Through the use of an endoscopic balloon probe and high-speed optical frequency domain imaging, the entire distal esophagus was imaged. The depth of imaging penetration was sufficient to visualize the full esophageal thickness.
    • (2008) Gastrointest Endosc , vol.68 , pp. 745-753
    • Suter, M.J.1    Vakoc, B.J.2    Yachimski, P.S.3    Shishkov, M.4    Lauwers, G.Y.5    Mino-Kenudson, M.6    Bouma, B.E.7    Nishioka, N.S.8    Tearney, G.J.9
  • 59
    • 49749107861 scopus 로고    scopus 로고
    • A pilot study of fourier-domain optical coherence tomography of retinal dystrophy patients
    • The authors report results from a clinical study of retinal dystrophy using spectral-domain OCT to quantify macular inner retinal layer and macular outer retinal layer thicknesses. The high resolution of the imaging system allowed quantitative analysis of the anatomical retinal layers while the high speed of SD-OCT permitted imaging over large areas of the retina.
    • Lim J.I., Tan O., Fawzi A.A., Hopkins J.J., Gil-Flamer J.H., and Huang D. A pilot study of fourier-domain optical coherence tomography of retinal dystrophy patients. Am J Ophthalmol 146 (2008) 417-426. The authors report results from a clinical study of retinal dystrophy using spectral-domain OCT to quantify macular inner retinal layer and macular outer retinal layer thicknesses. The high resolution of the imaging system allowed quantitative analysis of the anatomical retinal layers while the high speed of SD-OCT permitted imaging over large areas of the retina.
    • (2008) Am J Ophthalmol , vol.146 , pp. 417-426
    • Lim, J.I.1    Tan, O.2    Fawzi, A.A.3    Hopkins, J.J.4    Gil-Flamer, J.H.5    Huang, D.6
  • 60
    • 56049124296 scopus 로고    scopus 로고
    • Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging: first-in-man experience
    • Using optical frequency domain imaging, the authors demonstrate comprehensive intracoronary imaging in human patients. This is the first study demonstrating high-resolution cross-sectional and three-dimensional OCT imaging over long coronary segments.
    • Tearney G.J., Waxman S., Shishkov M., Vakoc B.J., Suter M.J., Freilich M.I., Desjardins A.E., Oh W.Y., Bartlett L.A., Rosenberg M., et al. Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging: first-in-man experience. JACC Cardiovasc Imaging 1 (2008) 752-761. Using optical frequency domain imaging, the authors demonstrate comprehensive intracoronary imaging in human patients. This is the first study demonstrating high-resolution cross-sectional and three-dimensional OCT imaging over long coronary segments.
    • (2008) JACC Cardiovasc Imaging , vol.1 , pp. 752-761
    • Tearney, G.J.1    Waxman, S.2    Shishkov, M.3    Vakoc, B.J.4    Suter, M.J.5    Freilich, M.I.6    Desjardins, A.E.7    Oh, W.Y.8    Bartlett, L.A.9    Rosenberg, M.10
  • 61
    • 0000063298 scopus 로고    scopus 로고
    • In vivo bidirectional color doppler flow imaging of picoliter blood volumes using optical coherence tomography
    • Izatt J.A., Kulkarni M.D., Yazdanfar S., Barton J.K., and Welch A.J. In vivo bidirectional color doppler flow imaging of picoliter blood volumes using optical coherence tomography. Opt Lett 22 (1997) 1439-1441
    • (1997) Opt Lett , vol.22 , pp. 1439-1441
    • Izatt, J.A.1    Kulkarni, M.D.2    Yazdanfar, S.3    Barton, J.K.4    Welch, A.J.5
  • 62
    • 84975582308 scopus 로고
    • Characterization of fluid flow velocity by optical doppler tomography
    • Wang X.J., Milner T.E., and Nelson J.S. Characterization of fluid flow velocity by optical doppler tomography. Opt Lett 20 (1995) 1337-1339
    • (1995) Opt Lett , vol.20 , pp. 1337-1339
    • Wang, X.J.1    Milner, T.E.2    Nelson, J.S.3
  • 63
    • 84975598528 scopus 로고
    • Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
    • Hee M.R., Huang D., Swanson E.A., and Fujimoto J.G. Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging. J Opt Soc Am B 9 (1992) 903-908
    • (1992) J Opt Soc Am B , vol.9 , pp. 903-908
    • Hee, M.R.1    Huang, D.2    Swanson, E.A.3    Fujimoto, J.G.4
  • 64
    • 0000063297 scopus 로고    scopus 로고
    • Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography
    • de Boer J.F., Milner T.E., van Gemert M.J.C., and Nelson J.S. Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography. Opt Lett 22 (1997) 934-936
    • (1997) Opt Lett , vol.22 , pp. 934-936
    • de Boer, J.F.1    Milner, T.E.2    van Gemert, M.J.C.3    Nelson, J.S.4
  • 65
    • 0000862635 scopus 로고    scopus 로고
    • Birefringence characterization of biological tissue by use of optical coherence tomography
    • Everett M.J., Schoenenberger K., Colston J.B.W., and Da Silva L.B. Birefringence characterization of biological tissue by use of optical coherence tomography. Opt Lett 23 (1998) 228-230
    • (1998) Opt Lett , vol.23 , pp. 228-230
    • Everett, M.J.1    Schoenenberger, K.2    Colston, J.B.W.3    Da Silva, L.B.4
  • 66
    • 3142760010 scopus 로고    scopus 로고
    • Near-infrared dyes as contrast-enhancing agents for spectroscopic opticalcoherence tomography
    • Xu C., Ye J., Marks D.L., and Boppart S.A. Near-infrared dyes as contrast-enhancing agents for spectroscopic opticalcoherence tomography. Opt Lett 29 (2004) 1647-1649
    • (2004) Opt Lett , vol.29 , pp. 1647-1649
    • Xu, C.1    Ye, J.2    Marks, D.L.3    Boppart, S.A.4
  • 67
    • 33749375143 scopus 로고    scopus 로고
    • Molecular imaging of endogenous and exogenous chromophores using ground state recovery pump-probe optical coherence tomography
    • The authors exploit transient absorption through pump-probe techniques to integrate molecular specificity with the high spatial resolution of OCT.
    • Applegate B.E., and Izatt J.A. Molecular imaging of endogenous and exogenous chromophores using ground state recovery pump-probe optical coherence tomography. Opt Exp 14 (2006) 9142-9155. The authors exploit transient absorption through pump-probe techniques to integrate molecular specificity with the high spatial resolution of OCT.
    • (2006) Opt Exp , vol.14 , pp. 9142-9155
    • Applegate, B.E.1    Izatt, J.A.2
  • 68
    • 2542437725 scopus 로고    scopus 로고
    • Second-harmonic optical coherence tomography
    • Jiang Y., Tomov I., Wang Y., and Chen Z. Second-harmonic optical coherence tomography. Opt Lett 29 (2004) 1090-1092
    • (2004) Opt Lett , vol.29 , pp. 1090-1092
    • Jiang, Y.1    Tomov, I.2    Wang, Y.3    Chen, Z.4
  • 69
    • 85032425798 scopus 로고    scopus 로고
    • Nonlinear interferometric vibrational imaging
    • Marks D.L., and Boppart S.A. Nonlinear interferometric vibrational imaging. Phys Rev Lett 92 (2004) 123905-1-123905-4
    • (2004) Phys Rev Lett , vol.92
    • Marks, D.L.1    Boppart, S.A.2
  • 70
    • 16244419054 scopus 로고    scopus 로고
    • Imaging magnetically labeled cells with magnetomotive optical coherence tomography
    • Oldenburg A.L., Gunther J.R., and Boppart S.A. Imaging magnetically labeled cells with magnetomotive optical coherence tomography. Opt Lett 30 (2005) 747-749
    • (2005) Opt Lett , vol.30 , pp. 747-749
    • Oldenburg, A.L.1    Gunther, J.R.2    Boppart, S.A.3
  • 71
    • 0037364156 scopus 로고    scopus 로고
    • Molecular contrast in optical coherence tomography by use of a pump probe technique
    • Rao K.D., Choma M.A., Yazdanfar S., Rollins A.M., and Izatt J.A. Molecular contrast in optical coherence tomography by use of a pump probe technique. Opt Lett 28 (2003) 340-342
    • (2003) Opt Lett , vol.28 , pp. 340-342
    • Rao, K.D.1    Choma, M.A.2    Yazdanfar, S.3    Rollins, A.M.4    Izatt, J.A.5
  • 72
    • 2942550644 scopus 로고    scopus 로고
    • Protein-based molecular contrast optical coherence tomography withphytochrome as the contrast agent
    • Yang C., Choma M.A., Lamb L.E., Simon J.D., and Izatt J.A. Protein-based molecular contrast optical coherence tomography withphytochrome as the contrast agent. Opt Lett 29 (2004) 1396-1398
    • (2004) Opt Lett , vol.29 , pp. 1396-1398
    • Yang, C.1    Choma, M.A.2    Lamb, L.E.3    Simon, J.D.4    Izatt, J.A.5
  • 73
  • 74
    • 47549090614 scopus 로고    scopus 로고
    • Phase-resolved doppler optical coherence tomography-limitations and improvements
    • Szkulmowska A., Szkulmowski M., Kowalczyk A., and Wojtkowski M. Phase-resolved doppler optical coherence tomography-limitations and improvements. Opt Lett 33 (2008) 1425-1427
    • (2008) Opt Lett , vol.33 , pp. 1425-1427
    • Szkulmowska, A.1    Szkulmowski, M.2    Kowalczyk, A.3    Wojtkowski, M.4
  • 76
    • 47849098802 scopus 로고    scopus 로고
    • In vivo volumetric imaging of vascular perfusion within human retina and choroids with optical micro-angiography
    • An L., and Wang R.K.K. In vivo volumetric imaging of vascular perfusion within human retina and choroids with optical micro-angiography. Opt Exp 16 (2008) 11438-11452
    • (2008) Opt Exp , vol.16 , pp. 11438-11452
    • An, L.1    Wang, R.K.K.2
  • 77
    • 33745873723 scopus 로고    scopus 로고
    • Fiber-based polarization-sensitive fourier domain optical coherence tomography using b-scan-oriented polarization modulation method
    • Yamanari M., Makita S., Madjarova V.D., Yatagai T., and Yasuno Y. Fiber-based polarization-sensitive fourier domain optical coherence tomography using b-scan-oriented polarization modulation method. Opt Exp 14 (2006) 6502-6515
    • (2006) Opt Exp , vol.14 , pp. 6502-6515
    • Yamanari, M.1    Makita, S.2    Madjarova, V.D.3    Yatagai, T.4    Yasuno, Y.5
  • 78
    • 33846893237 scopus 로고    scopus 로고
    • Single camera based spectral domain polarization sensitive optical coherence tomography
    • Baumann B., Gotzinger E., Pircher M., and Hitzenberger C.K. Single camera based spectral domain polarization sensitive optical coherence tomography. Opt Exp 15 (2007) 1054-1063
    • (2007) Opt Exp , vol.15 , pp. 1054-1063
    • Baumann, B.1    Gotzinger, E.2    Pircher, M.3    Hitzenberger, C.K.4
  • 80
    • 42149103845 scopus 로고    scopus 로고
    • Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation
    • Yamanari M., Makita S., and Yasuno Y. Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation. Opt Exp 16 (2008) 5892-5906
    • (2008) Opt Exp , vol.16 , pp. 5892-5906
    • Yamanari, M.1    Makita, S.2    Yasuno, Y.3
  • 81
    • 46149109273 scopus 로고    scopus 로고
    • Single-detector polarization-sensitive optical frequency domain imaging using high-speed intra a-line polarization modulation
    • Oh W.Y., Vakoc B.J., Yun S.H., Tearney G.J., and Bouma B.E. Single-detector polarization-sensitive optical frequency domain imaging using high-speed intra a-line polarization modulation. Opt Lett 33 (2008) 1330-1332
    • (2008) Opt Lett , vol.33 , pp. 1330-1332
    • Oh, W.Y.1    Vakoc, B.J.2    Yun, S.H.3    Tearney, G.J.4    Bouma, B.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.