메뉴 건너뛰기




Volumn 16, Issue 3, 2009, Pages 200-206

Cemented versus uncemented fixation of the femoral component of the NexGen CR total knee replacement in patients younger than 60 years. A Prospective Randomised Controlled RSA Study

Author keywords

Cemented femoral fixation; Radiostereometric analysis; Randomised controlled trial; Total knee arthroplasty; Uncemented femoral fixation

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC VALUE; FEMALE; FIXATION DEVICE; HUMAN; KNEE PROSTHESIS; KNEE RADIOGRAPHY; MALE; OSTEOARTHRITIS; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; STEREORADIOGRAPHY; TOTAL KNEE REPLACEMENT;

EID: 65049084892     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.knee.2008.11.009     Document Type: Article
Times cited : (58)

References (36)
  • 1
    • 0036850551 scopus 로고    scopus 로고
    • Session Sh{cyrillic}: total knee replacement in young patients
    • Laskin R.S. Session Sh{cyrillic}: total knee replacement in young patients. Clin Orthop Relat Res 404 (2002) 100-101
    • (2002) Clin Orthop Relat Res , vol.404 , pp. 100-101
    • Laskin, R.S.1
  • 2
    • 2342587431 scopus 로고    scopus 로고
    • Higher cumulative revision rate of knee arthroplasties in younger patients with osteoarthritis
    • Harrysson O.L., Robertsson O., and Nayfeh J.F. Higher cumulative revision rate of knee arthroplasties in younger patients with osteoarthritis. Clin Orthop Relat Res 421 (2004) 162-168
    • (2004) Clin Orthop Relat Res , vol.421 , pp. 162-168
    • Harrysson, O.L.1    Robertsson, O.2    Nayfeh, J.F.3
  • 4
    • 0032430471 scopus 로고    scopus 로고
    • Femoral component failure in hybrid total knee arthroplasty
    • Campbell M.D., Duffy G.P., and Trousdale R.T. Femoral component failure in hybrid total knee arthroplasty. Clin Orthop Relat Res 356 (1998) 58-65
    • (1998) Clin Orthop Relat Res , vol.356 , pp. 58-65
    • Campbell, M.D.1    Duffy, G.P.2    Trousdale, R.T.3
  • 5
    • 0033694357 scopus 로고    scopus 로고
    • The outcome of cemented vs. cementless fixation of a femoral component in total knee replacement (TKR) with the identification of radiological signs for the prediction of failure
    • Chockalingam S., and Scott G. The outcome of cemented vs. cementless fixation of a femoral component in total knee replacement (TKR) with the identification of radiological signs for the prediction of failure. Knee 7 (2000) 233-238
    • (2000) Knee , vol.7 , pp. 233-238
    • Chockalingam, S.1    Scott, G.2
  • 7
    • 0017235711 scopus 로고
    • Acute local tissue effects of polymerizing acrylic bone cement. An intravital microscopic study in the hamster's cheek pouch on the chemically induced microvascular changes
    • Linder L., and Romanus M. Acute local tissue effects of polymerizing acrylic bone cement. An intravital microscopic study in the hamster's cheek pouch on the chemically induced microvascular changes. Clin Orthop Relat Res 115 (1976) 291-302
    • (1976) Clin Orthop Relat Res , vol.115 , pp. 291-302
    • Linder, L.1    Romanus, M.2
  • 8
    • 0026410326 scopus 로고
    • Removal torque for bone-cement and titanium screws implanted in rabbits
    • Morberg P., and Albrektsson T. Removal torque for bone-cement and titanium screws implanted in rabbits. Acta Orthop Scand 62 (1991) 554-556
    • (1991) Acta Orthop Scand , vol.62 , pp. 554-556
    • Morberg, P.1    Albrektsson, T.2
  • 9
    • 0022990794 scopus 로고
    • Loosening of the cemented hip prosthesis. The importance of heat injury
    • Suppl 221
    • Mjöberg B. Loosening of the cemented hip prosthesis. The importance of heat injury. Acta Orthop Scand (1986) 1-40 Suppl 221
    • (1986) Acta Orthop Scand , pp. 1-40
    • Mjöberg, B.1
  • 10
    • 0028212235 scopus 로고
    • Effects of polymerization heat and monomers from acrylic cement on canine bone
    • Stürup J., Nimb L., Kramhøft M., and Jensen J.S. Effects of polymerization heat and monomers from acrylic cement on canine bone. Acta Orthop Scand 65 (1994) 20-23
    • (1994) Acta Orthop Scand , vol.65 , pp. 20-23
    • Stürup, J.1    Nimb, L.2    Kramhøft, M.3    Jensen, J.S.4
  • 11
    • 0026550544 scopus 로고
    • The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy
    • Schmalzried T.P., Kwong L.M., Jasty M., Sedlacek R.C., Haire T.C., O'Connor D.O., et al. The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. Clin Orthop Relat Res 274 (1992) 60-78
    • (1992) Clin Orthop Relat Res , vol.274 , pp. 60-78
    • Schmalzried, T.P.1    Kwong, L.M.2    Jasty, M.3    Sedlacek, R.C.4    Haire, T.C.5    O'Connor, D.O.6
  • 12
    • 0028922153 scopus 로고
    • Tissue reactions to cemented hip sockets. Histologic and morphometric autopsy study of 25 acetabula
    • Bos I., Fredebold D., Diebold J., and Löhrs U. Tissue reactions to cemented hip sockets. Histologic and morphometric autopsy study of 25 acetabula. Acta Orthop Scand 66 (1995) 1-8
    • (1995) Acta Orthop Scand , vol.66 , pp. 1-8
    • Bos, I.1    Fredebold, D.2    Diebold, J.3    Löhrs, U.4
  • 13
    • 0026352980 scopus 로고
    • The histomorphologic and morphometric study of asymptomatic hip arthroplasty. A post-mortem study
    • Fornasier V., Wright J., and Seligman J. The histomorphologic and morphometric study of asymptomatic hip arthroplasty. A post-mortem study. Clin Orthop Relat Res 271 (1991) 272-282
    • (1991) Clin Orthop Relat Res , vol.271 , pp. 272-282
    • Fornasier, V.1    Wright, J.2    Seligman, J.3
  • 14
    • 0023036189 scopus 로고
    • The bone-cement interface in hip arthroplasty. A histologic and enzyme study of stable components
    • Linder L., and Carlsson Å.S. The bone-cement interface in hip arthroplasty. A histologic and enzyme study of stable components. Acta Orthop Scand 57 (1986) 495-500
    • (1986) Acta Orthop Scand , vol.57 , pp. 495-500
    • Linder, L.1    Carlsson, Å.S.2
  • 15
    • 33746879965 scopus 로고    scopus 로고
    • Uncemented HA-coated implant is the optimum fixation for TKA in the young patient
    • Nilsson K.G., Henricson A., Norgren B., and Dalén T. Uncemented HA-coated implant is the optimum fixation for TKA in the young patient. Clin Orthop Relat Res 448 (2006) 129-139
    • (2006) Clin Orthop Relat Res , vol.448 , pp. 129-139
    • Nilsson, K.G.1    Henricson, A.2    Norgren, B.3    Dalén, T.4
  • 16
    • 1642545229 scopus 로고    scopus 로고
    • Arthroscopic debridement in the treatment of the infected total knee arthroplasty
    • Dixon P., Parish E.N., and Cross M.J. Arthroscopic debridement in the treatment of the infected total knee arthroplasty. J Bone Jt Surg Br 86 1 (2004) 39-42
    • (2004) J Bone Jt Surg Br , vol.86 , Issue.1 , pp. 39-42
    • Dixon, P.1    Parish, E.N.2    Cross, M.J.3
  • 17
    • 0029056371 scopus 로고
    • Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
    • Ryd L., Albrektsson B.E., Carlsson L., Dansgard F., Herberts P., Lindstrand A., et al. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Jt Surg Br 77 (1995) 377-383
    • (1995) J Bone Jt Surg Br , vol.77 , pp. 377-383
    • Ryd, L.1    Albrektsson, B.E.2    Carlsson, L.3    Dansgard, F.4    Herberts, P.5    Lindstrand, A.6
  • 18
    • 0029683530 scopus 로고    scopus 로고
    • RSA in the assessment of aseptic loosening
    • Nilsson K.G., and Kärrholm J. RSA in the assessment of aseptic loosening. J Bone Jt Surg Br 78 (1996) 1-3
    • (1996) J Bone Jt Surg Br , vol.78 , pp. 1-3
    • Nilsson, K.G.1    Kärrholm, J.2
  • 19
    • 0031757919 scopus 로고    scopus 로고
    • Inferior performance of Boneloc bone cement in total knee arthroplasty: a prospective randomized study comparing Boneloc with Palacos using radiostereometry (RSA) in 19 patients
    • Nilsson K.G., and Dalén T. Inferior performance of Boneloc bone cement in total knee arthroplasty: a prospective randomized study comparing Boneloc with Palacos using radiostereometry (RSA) in 19 patients. Acta Orthop Scand 69 (1998) 479-483
    • (1998) Acta Orthop Scand , vol.69 , pp. 479-483
    • Nilsson, K.G.1    Dalén, T.2
  • 21
    • 0024950156 scopus 로고
    • The Knee Society total knee arthroplasty roentgenographic evaluation and scoring form
    • Ewald F.C. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring form. Clin Orthop Relat Res 248 (1989) 9-12
    • (1989) Clin Orthop Relat Res , vol.248 , pp. 9-12
    • Ewald, F.C.1
  • 23
    • 0022542239 scopus 로고
    • Micromotion in knee arthroplasty: a roentgen stereophotogrammetric analysis of tibial component fixation
    • Suppl 220
    • Ryd L. Micromotion in knee arthroplasty: a roentgen stereophotogrammetric analysis of tibial component fixation. Acta Orthop Scand (1986) 1-60 Suppl 220
    • (1986) Acta Orthop Scand , pp. 1-60
    • Ryd, L.1
  • 24
    • 0029062186 scopus 로고
    • Femoral component migration in total knee arthroplasty: randomized study comparing cemented and uncemented fixation of the Miller-Galante I design
    • Nilsson K.G., Kärrholm J., and Linder L. Femoral component migration in total knee arthroplasty: randomized study comparing cemented and uncemented fixation of the Miller-Galante I design. J Orthop Res 13 (1995) 347-356
    • (1995) J Orthop Res , vol.13 , pp. 347-356
    • Nilsson, K.G.1    Kärrholm, J.2    Linder, L.3
  • 25
    • 0034132382 scopus 로고    scopus 로고
    • Accurate accuracy assessment: review of basic principles
    • Ranstam J., Ryd L., and Önsten I. Accurate accuracy assessment: review of basic principles. Acta Orthop Scand 71 (2000) 106-108
    • (2000) Acta Orthop Scand , vol.71 , pp. 106-108
    • Ranstam, J.1    Ryd, L.2    Önsten, I.3
  • 26
    • 0033009371 scopus 로고    scopus 로고
    • Total knee replacement: should it be cemented or hybrid?
    • Rorabeck C.H. Total knee replacement: should it be cemented or hybrid?. Can J Surg 42 (1999) 21-26
    • (1999) Can J Surg , vol.42 , pp. 21-26
    • Rorabeck, C.H.1
  • 27
    • 33644800146 scopus 로고    scopus 로고
    • Zone 4 femoral radiolucent lines in hybrid versus cemented total knee arthroplasties: are they clinically significant?
    • Huddleston J.I., Wiley J.W., and Scott R.D. Zone 4 femoral radiolucent lines in hybrid versus cemented total knee arthroplasties: are they clinically significant?. Clin Orthop Relat Res 441 (2005) 334-339
    • (2005) Clin Orthop Relat Res , vol.441 , pp. 334-339
    • Huddleston, J.I.1    Wiley, J.W.2    Scott, R.D.3
  • 28
    • 33846891367 scopus 로고    scopus 로고
    • Cemented versus hydroxyapatite fixation of the femoral component of the Freeman-Samuelson total knee replacement: a radiostereometric analysis
    • Uvehammer J., Kärrholm J., and Carlsson L. Cemented versus hydroxyapatite fixation of the femoral component of the Freeman-Samuelson total knee replacement: a radiostereometric analysis. J Bone Jt Surg Br 89 (2007) 39-44
    • (2007) J Bone Jt Surg Br , vol.89 , pp. 39-44
    • Uvehammer, J.1    Kärrholm, J.2    Carlsson, L.3
  • 30
    • 0031720017 scopus 로고    scopus 로고
    • Total knee arthroplasty with the PFC system. Results at a minimum of ten years and survivorship analysis
    • Schai P.A., Thornhill T.S., and Scott R.D. Total knee arthroplasty with the PFC system. Results at a minimum of ten years and survivorship analysis. J Bone Jt Surg Br 80 (1998) 850-858
    • (1998) J Bone Jt Surg Br , vol.80 , pp. 850-858
    • Schai, P.A.1    Thornhill, T.S.2    Scott, R.D.3
  • 31
    • 0035032191 scopus 로고    scopus 로고
    • Long-term results of Kinematic Condylar knee replacement. An analysis of 404 knees
    • Gill G.S., and Joshi A.B. Long-term results of Kinematic Condylar knee replacement. An analysis of 404 knees. J Bone Jt Surg Br 83 (2001) 355-358
    • (2001) J Bone Jt Surg Br , vol.83 , pp. 355-358
    • Gill, G.S.1    Joshi, A.B.2
  • 32
    • 0034959851 scopus 로고    scopus 로고
    • Long-term follow up of anatomic graduated components posterior cruciate-retaining total knee replacement
    • Ritter M.A., Berend M.E., Meding J.B., Keating E.M., Faris P.M., and Crites B.M. Long-term follow up of anatomic graduated components posterior cruciate-retaining total knee replacement. Clin Orthop Relat Res 388 (2001) 51-57
    • (2001) Clin Orthop Relat Res , vol.388 , pp. 51-57
    • Ritter, M.A.1    Berend, M.E.2    Meding, J.B.3    Keating, E.M.4    Faris, P.M.5    Crites, B.M.6
  • 33
    • 33748880669 scopus 로고    scopus 로고
    • Five-to 12-year follow-up of a hydroxyapatite-coated, cementless total knee replacement in young, active patients
    • Tai C.C., and Cross M.J. Five-to 12-year follow-up of a hydroxyapatite-coated, cementless total knee replacement in young, active patients. J Bone Jt Surg Br 88 (2006) 1158-1163
    • (2006) J Bone Jt Surg Br , vol.88 , pp. 1158-1163
    • Tai, C.C.1    Cross, M.J.2
  • 34
    • 0031785763 scopus 로고    scopus 로고
    • The effect of hydroxyapatite on the micromotion of total knee prostheses. A prospective randomized, double-blind study
    • Nelissen R.G., Valstar E.R., and Rozing P.M. The effect of hydroxyapatite on the micromotion of total knee prostheses. A prospective randomized, double-blind study. J Bone Jt Surg Am 80 (1998) 1665-1672
    • (1998) J Bone Jt Surg Am , vol.80 , pp. 1665-1672
    • Nelissen, R.G.1    Valstar, E.R.2    Rozing, P.M.3
  • 35
    • 0021912380 scopus 로고
    • Femoral component loosening in total knee arthroplasty
    • King T.V., and Scott R.D. Femoral component loosening in total knee arthroplasty. Clin Orthop Relat Res 194 (1985) 285-290
    • (1985) Clin Orthop Relat Res , vol.194 , pp. 285-290
    • King, T.V.1    Scott, R.D.2
  • 36
    • 0024958083 scopus 로고
    • Mechanisms of failure of the femoral and tibial components in total knee arthroplasty
    • Windsor R.E., Scuderi G.R., Moran M.C., and Insall J.N. Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res 248 (1989) 15-20
    • (1989) Clin Orthop Relat Res , vol.248 , pp. 15-20
    • Windsor, R.E.1    Scuderi, G.R.2    Moran, M.C.3    Insall, J.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.