-
1
-
-
0022645576
-
Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions
-
Veith F.J., Gupta S.K., Ascer E., White-Flores S., Samson R.H., Scher L.A., et al. Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions. J Vasc Surg 3 (1986) 104-114
-
(1986)
J Vasc Surg
, vol.3
, pp. 104-114
-
-
Veith, F.J.1
Gupta, S.K.2
Ascer, E.3
White-Flores, S.4
Samson, R.H.5
Scher, L.A.6
-
2
-
-
0033840872
-
A prospective randomized trial comparing vein with polytetrafluoroethylene in above-knee femoropopliteal bypass grafting
-
Burger D.H., Kappetein A.P., van Bockel J.H., and Breslau P.J. A prospective randomized trial comparing vein with polytetrafluoroethylene in above-knee femoropopliteal bypass grafting. J Vasc Surg 32 (2000) 278-283
-
(2000)
J Vasc Surg
, vol.32
, pp. 278-283
-
-
Burger, D.H.1
Kappetein, A.P.2
van Bockel, J.H.3
Breslau, P.J.4
-
3
-
-
0033840519
-
A comparative evaluation of polytetrafluoroethylene, umbilical vein, and saphenous vein bypass grafts for femoral-popliteal above-knee revascularization: a prospective randomized Department of Veterans Affairs cooperative study
-
Johnson W.C., and Lee K.K. A comparative evaluation of polytetrafluoroethylene, umbilical vein, and saphenous vein bypass grafts for femoral-popliteal above-knee revascularization: a prospective randomized Department of Veterans Affairs cooperative study. J Vasc Surg 32 (2000) 268-277
-
(2000)
J Vasc Surg
, vol.32
, pp. 268-277
-
-
Johnson, W.C.1
Lee, K.K.2
-
4
-
-
0037955987
-
Improvements in GORE-TEX vascular graft performance by Carmeda BioActive surface heparin immobilization
-
Begovac P.C., Thomson R.C., Fisher J.L., Hughson A., and Gällhagen A. Improvements in GORE-TEX vascular graft performance by Carmeda BioActive surface heparin immobilization. Eur J Vasc Endovasc Surg 25 (2003) 432-437
-
(2003)
Eur J Vasc Endovasc Surg
, vol.25
, pp. 432-437
-
-
Begovac, P.C.1
Thomson, R.C.2
Fisher, J.L.3
Hughson, A.4
Gällhagen, A.5
-
6
-
-
27744567946
-
Infrainguinal ePTFE vascular graft with bioactive surface heparin bonding. First clinical results
-
Walluscheck K.P., Bierkandt S., Brandt M., and Cremer J. Infrainguinal ePTFE vascular graft with bioactive surface heparin bonding. First clinical results. J Cardiovasc Surg (Torino) 46 (2005) 425-430
-
(2005)
J Cardiovasc Surg (Torino)
, vol.46
, pp. 425-430
-
-
Walluscheck, K.P.1
Bierkandt, S.2
Brandt, M.3
Cremer, J.4
-
7
-
-
34249818754
-
Lower limb revascularization with a new bioactive prosthetic graft: a case-control study
-
Dorigo W., Pulli R., Barbanti E., Azas L., Troisi N., Pratesi G., et al. Lower limb revascularization with a new bioactive prosthetic graft: a case-control study. Interact Cardiovasc Thorac Surg 6 (2007) 369-373
-
(2007)
Interact Cardiovasc Thorac Surg
, vol.6
, pp. 369-373
-
-
Dorigo, W.1
Pulli, R.2
Barbanti, E.3
Azas, L.4
Troisi, N.5
Pratesi, G.6
-
8
-
-
33645291744
-
Retrospective comparison of a heparin bonded ePTFE graft and saphenous vein for infragenicular bypass: implications for standard treatment protocol
-
Battaglia G., Tringale R., and Monaca V. Retrospective comparison of a heparin bonded ePTFE graft and saphenous vein for infragenicular bypass: implications for standard treatment protocol. J Cardiovasc Surg (Torino) 47 (2006) 41-47
-
(2006)
J Cardiovasc Surg (Torino)
, vol.47
, pp. 41-47
-
-
Battaglia, G.1
Tringale, R.2
Monaca, V.3
-
9
-
-
32344450578
-
Heparin-bonded expanded polytetrafluoroethylene vascular graft for femoropopliteal and femorocrural bypass grafting: 1-year results
-
discussion 318-9
-
Bosiers M., Deloose K., Verbist J., Schroë H., Lauwers G., Lansink W., and Peeters P. Heparin-bonded expanded polytetrafluoroethylene vascular graft for femoropopliteal and femorocrural bypass grafting: 1-year results. J Vasc Surg 43 (2006) 313-318 discussion 318-9
-
(2006)
J Vasc Surg
, vol.43
, pp. 313-318
-
-
Bosiers, M.1
Deloose, K.2
Verbist, J.3
Schroë, H.4
Lauwers, G.5
Lansink, W.6
Peeters, P.7
-
10
-
-
33749058546
-
Results with heparin bonded polytetrafluoroethylene grafts for femorodistal bypasses
-
Peeters P., Verbist J., Deloose K., and Bosiers M. Results with heparin bonded polytetrafluoroethylene grafts for femorodistal bypasses. J Cardiovasc Surg (Torino) 47 (2006) 407-413
-
(2006)
J Cardiovasc Surg (Torino)
, vol.47
, pp. 407-413
-
-
Peeters, P.1
Verbist, J.2
Deloose, K.3
Bosiers, M.4
-
11
-
-
27744567946
-
Infrainguinal ePTEE vascular graft with bioactive surface heparin bonding. First clinical results
-
Walluscheck K.P., Bierkandt S., Brandt M., and Cremer J. Infrainguinal ePTEE vascular graft with bioactive surface heparin bonding. First clinical results. J Cardiovasc Surg (Torino) 46 (2005) 425-430
-
(2005)
J Cardiovasc Surg (Torino)
, vol.46
, pp. 425-430
-
-
Walluscheck, K.P.1
Bierkandt, S.2
Brandt, M.3
Cremer, J.4
-
12
-
-
0035130414
-
Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operations
-
Ovrum E., Tangen G., Oystese R., Ringdal M.A., and Istad R. Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operations. J Thorac Cardiovasc Surg 121 (2001) 324-330
-
(2001)
J Thorac Cardiovasc Surg
, vol.121
, pp. 324-330
-
-
Ovrum, E.1
Tangen, G.2
Oystese, R.3
Ringdal, M.A.4
Istad, R.5
-
14
-
-
0032578319
-
Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II)
-
Serruys P.W., van Hout B., Bonnier H., Legrand V., Garcia E., Macaya C., et al. Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II). Lancet 352 (1998) 673-681
-
(1998)
Lancet
, vol.352
, pp. 673-681
-
-
Serruys, P.W.1
van Hout, B.2
Bonnier, H.3
Legrand, V.4
Garcia, E.5
Macaya, C.6
-
15
-
-
1842839912
-
Evaluation of platelet deposition and neointimal hyperplasia of heparin-coated small-caliber ePTFE grafts in a canine femoral artery bypass model
-
Lin P.H., Bush R.L., Yao Q., Lumsden A.B., and Chen C. Evaluation of platelet deposition and neointimal hyperplasia of heparin-coated small-caliber ePTFE grafts in a canine femoral artery bypass model. J Surg Res 118 (2004) 45-52
-
(2004)
J Surg Res
, vol.118
, pp. 45-52
-
-
Lin, P.H.1
Bush, R.L.2
Yao, Q.3
Lumsden, A.B.4
Chen, C.5
-
16
-
-
3242701663
-
Small-caliber heparin-coated ePTFE grafts reduce platelet deposition and neointimal hyperplasia in a baboon model
-
Lin P.H., Chen C., Bush R.L., Yao Q., Lumsden A.B., and Hanson S.R. Small-caliber heparin-coated ePTFE grafts reduce platelet deposition and neointimal hyperplasia in a baboon model. J Vasc Surg 39 (2004) 1322-1328
-
(2004)
J Vasc Surg
, vol.39
, pp. 1322-1328
-
-
Lin, P.H.1
Chen, C.2
Bush, R.L.3
Yao, Q.4
Lumsden, A.B.5
Hanson, S.R.6
-
17
-
-
33644663673
-
Heparin immobilization reduces thrombogenicity of small-caliber expanded polytetrafluoroethylene grafts
-
Heyligers J.M., Verhagen H.J., Rotmans J.I., Weeterings C., de Groot P.G., Moll F.L., and Lisman T. Heparin immobilization reduces thrombogenicity of small-caliber expanded polytetrafluoroethylene grafts. J Vasc Surg 43 (2006) 587-591
-
(2006)
J Vasc Surg
, vol.43
, pp. 587-591
-
-
Heyligers, J.M.1
Verhagen, H.J.2
Rotmans, J.I.3
Weeterings, C.4
de Groot, P.G.5
Moll, F.L.6
Lisman, T.7
-
18
-
-
0038410135
-
Meta-analysis of polytetrafluoroethylene bypass grafts to infrapopliteal arteries
-
Albers M., Battistella V.M., Romiti M., Rodrigues A.A., and Pereira C.A. Meta-analysis of polytetrafluoroethylene bypass grafts to infrapopliteal arteries. J Vasc Surg 37 (2003) 1263-1269
-
(2003)
J Vasc Surg
, vol.37
, pp. 1263-1269
-
-
Albers, M.1
Battistella, V.M.2
Romiti, M.3
Rodrigues, A.A.4
Pereira, C.A.5
-
19
-
-
0021884759
-
In situ saphenous vein bypass grafts for limb salvage. A current fad or a viable alternative to reversed vein bypass grafts?
-
Bush Jr. H.L., Nabseth D.C., Curl G.R., O'Hara E.T., Johnson W.C., and Vollman R.W. In situ saphenous vein bypass grafts for limb salvage. A current fad or a viable alternative to reversed vein bypass grafts?. Am J Surg 149 (1985) 477-480
-
(1985)
Am J Surg
, vol.149
, pp. 477-480
-
-
Bush Jr., H.L.1
Nabseth, D.C.2
Curl, G.R.3
O'Hara, E.T.4
Johnson, W.C.5
Vollman, R.W.6
-
20
-
-
0025165898
-
Comparison of in-situ and reversed saphenous vein grafts for infrageniculate bypass
-
Ricci M.A., Graham A.M., and Symes J.F. Comparison of in-situ and reversed saphenous vein grafts for infrageniculate bypass. Can J Surg 33 (1990) 216-220
-
(1990)
Can J Surg
, vol.33
, pp. 216-220
-
-
Ricci, M.A.1
Graham, A.M.2
Symes, J.F.3
-
21
-
-
0025105260
-
Present status of reversed vein bypass grafting: five-year results of a modern series
-
discussion 205-6
-
Taylor Jr. L.M., Edwards J.M., and Porter J.M. Present status of reversed vein bypass grafting: five-year results of a modern series. J Vasc Surg 11 (1990) 193-205 discussion 205-6
-
(1990)
J Vasc Surg
, vol.11
, pp. 193-205
-
-
Taylor Jr., L.M.1
Edwards, J.M.2
Porter, J.M.3
|