메뉴 건너뛰기




Volumn 43, Issue 2, 2006, Pages 313-318

Heparin-bonded expanded polytetrafluoroethylene vascular graft for femoropopliteal and femorocrural bypass grafting: 1-year results

Author keywords

[No Author keywords available]

Indexed keywords

HEPARIN;

EID: 32344450578     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvs.2005.10.037     Document Type: Article
Times cited : (114)

References (25)
  • 1
    • 1642310221 scopus 로고    scopus 로고
    • Saphenous vein versus PTFE for above-knee femoropopliteal bypass. a review of the literature
    • P. Klinert, P.N. Post, P.J. Breslau, J.H. van Bockel Saphenous vein versus PTFE for above-knee femoropopliteal bypass. A review of the literature Eur J Vasc Endovasc Surg 27 2004 357 362
    • (2004) Eur J Vasc Endovasc Surg , vol.27 , pp. 357-362
    • Klinert, P.1    Post, P.N.2    Breslau, P.J.3    Van Bockel, J.H.4
  • 2
    • 0025860935 scopus 로고
    • PTFE or HUV for femoro-popliteal bypass: A multi-centre trial
    • Femoro-popliteal Bypass Trial Participants R.M.
    • C. McCollum, G. Kenchington, C. Alexander, P.J. Franks, R.M. Greenhalgh Femoro-popliteal Bypass Trial Participants PTFE or HUV for femoro-popliteal bypass a multi-centre trial Eur J Vasc Surg 5 1991 435 443
    • (1991) Eur J Vasc Surg , vol.5 , pp. 435-443
    • McCollum, C.1    Kenchington, G.2    Alexander, C.3    Franks, P.J.4    Greenhalgh5
  • 3
    • 0033840872 scopus 로고    scopus 로고
    • A prospective randomized trial comparing vein with polytetrafluoroethylene in above-knee femoropopliteal bypass grafting
    • D.H. Burger, A.P. Kappetein, J.H. van Bockel, P.J. Breslau A prospective randomized trial comparing vein with polytetrafluoroethylene in above-knee femoropopliteal bypass grafting J Vasc Surg 32 2000 278 283
    • (2000) J Vasc Surg , vol.32 , pp. 278-283
    • Burger, D.H.1    Kappetein, A.P.2    Van Bockel, J.H.3    Breslau, P.J.4
  • 4
    • 0033840519 scopus 로고    scopus 로고
    • A comparative evaluation of polytetrafluoroethylene, umbilical vein, and saphenous vein bypass grafts for femoral-popliteal above-knee revascularization: A prospective randomized Department of Veterans Affairs cooperative study
    • members of the Department of Veteran Affairs COOP Study 141 K.K.
    • W.C. Johnson, K.K. Lee members of the Department of Veteran Affairs COOP Study 141 A comparative evaluation of polytetrafluoroethylene, umbilical vein, and saphenous vein bypass grafts for femoral-popliteal above-knee revascularization a prospective randomized Department of Veterans Affairs cooperative study J Vasc Surg 32 2000 268 277
    • (2000) J Vasc Surg , vol.32 , pp. 268-277
    • Johnson, W.C.1    Lee2
  • 5
    • 0022645576 scopus 로고
    • Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions
    • F.J. Veith, S.K. Gupta, E. Ascer, S. White-Flores, R.H. Samson, L.A. Scher Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions J Vasc Surg 3 1986 104 114
    • (1986) J Vasc Surg , vol.3 , pp. 104-114
    • Veith, F.J.1    Gupta, S.K.2    Ascer, E.3    White-Flores, S.4    Samson, R.H.5    Scher, L.A.6
  • 6
    • 0037955987 scopus 로고    scopus 로고
    • Improvements in GORE-TEX® Vascular Graft performance by Carmeda® BioActive Surface heparin immobilization
    • P.C. Begovac, R.C. Thomson, J.L. Fisher, A. Hughson, A. Gällhagen Improvements in GORE-TEX® Vascular Graft performance by Carmeda® BioActive Surface heparin immobilization Eur J Vasc Endovasc Surg 25 2003 432 437
    • (2003) Eur J Vasc Endovasc Surg , vol.25 , pp. 432-437
    • Begovac, P.C.1    Thomson, R.C.2    Fisher, J.L.3    Hughson, A.4    Gällhagen, A.5
  • 7
    • 1842839912 scopus 로고    scopus 로고
    • Evaluation of platelet deposition and neointimal hyperplasia of heparin-coated small-caliber ePTFE grafts in a canine femoral artery bypass model
    • P.H. Lin, R.L. Bush, Q. Yao, A.B. Lumsden, C. Chen Evaluation of platelet deposition and neointimal hyperplasia of heparin-coated small-caliber ePTFE grafts in a canine femoral artery bypass model J Surg Res 118 2004 45 52
    • (2004) J Surg Res , vol.118 , pp. 45-52
    • Lin, P.H.1    Bush, R.L.2    Yao, Q.3    Lumsden, A.B.4    Chen, C.5
  • 8
    • 3242701663 scopus 로고    scopus 로고
    • Small-caliber heparin-coated ePTFE grafts reduce platelet deposition and neointimal hyperplasia in a baboon model
    • P.H. Lin, C. Chen, R.L. Bush, Q. Yao, A.B. Lumsden, S.R. Hanson Small-caliber heparin-coated ePTFE grafts reduce platelet deposition and neointimal hyperplasia in a baboon model J Vasc Surg 39 2004 1322 1328
    • (2004) J Vasc Surg , vol.39 , pp. 1322-1328
    • Lin, P.H.1    Chen, C.2    Bush, R.L.3    Yao, Q.4    Lumsden, A.B.5    Hanson, S.R.6
  • 9
    • 2342567759 scopus 로고    scopus 로고
    • Silyl-heparin bonding improves the patency and in vivo thromboresistance of carbon-coated polytetrafluoroethylene vascular grafts
    • J. Laredo, L. Xue, V.A. Husak, J. Ellinger, G. Singh, P.O. Zamora Silyl-heparin bonding improves the patency and in vivo thromboresistance of carbon-coated polytetrafluoroethylene vascular grafts J Vasc Surg 39 2004 1059 1065
    • (2004) J Vasc Surg , vol.39 , pp. 1059-1065
    • Laredo, J.1    Xue, L.2    Husak, V.A.3    Ellinger, J.4    Singh, G.5    Zamora, P.O.6
  • 10
    • 0035108808 scopus 로고    scopus 로고
    • Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: A multicenter trial
    • The North West Femoro-Popliteal Trial Participants C.
    • C. Devine, C. McCollum The North West Femoro-Popliteal Trial Participants Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting a multicenter trial J Vasc Surg 33 2001 533 539
    • (2001) J Vasc Surg , vol.33 , pp. 533-539
    • Devine, C.1    McCollum2
  • 11
    • 8844267664 scopus 로고    scopus 로고
    • Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass: Five-year results of a prospective randomized multicenter clinical trial
    • The North West Femoro-Popliteal Trial Participants C.
    • C. Devine, C. McCollum The North West Femoro-Popliteal Trial Participants Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass five-year results of a prospective randomized multicenter clinical trial J Vasc Surg 40 2004 924 931
    • (2004) J Vasc Surg , vol.40 , pp. 924-931
    • Devine, C.1    McCollum2
  • 13
    • 0034743341 scopus 로고    scopus 로고
    • Effect of Carmeda BioActive Surface coating versus Trillium Biopassive Surface coating of the oxygenator on circulating platelet drop during cardiopulmonary bypass
    • D.A. Palanzo, D.L. Zarro, N.J. Manley, R.M. Montesano, M. Quinn, B.A. Elmore Effect of Carmeda BioActive Surface coating versus Trillium Biopassive Surface coating of the oxygenator on circulating platelet drop during cardiopulmonary bypass Perfusion 16 2001 279 283
    • (2001) Perfusion , vol.16 , pp. 279-283
    • Palanzo, D.A.1    Zarro, D.L.2    Manley, N.J.3    Montesano, R.M.4    Quinn, M.5    Elmore, B.A.6
  • 14
    • 0035130414 scopus 로고    scopus 로고
    • Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operations
    • E. Ovrum, G. Tangen, R. Oystese, M.A. Ringdal, R. Istad Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operations J Thorac Cardiovasc Surg 121 2001 324 330
    • (2001) J Thorac Cardiovasc Surg , vol.121 , pp. 324-330
    • Ovrum, E.1    Tangen, G.2    Oystese, R.3    Ringdal, M.A.4    Istad, R.5
  • 17
    • 0032578319 scopus 로고    scopus 로고
    • Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II)
    • P.W. Serruys, B. van Hout, H. Bonnier, V. Legrand, E. Garcia, C. Macaya Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II) Lancet 352 1998 673 681
    • (1998) Lancet , vol.352 , pp. 673-681
    • Serruys, P.W.1    Van Hout, B.2    Bonnier, H.3    Legrand, V.4    Garcia, E.5    MacAya, C.6
  • 18
    • 0031852030 scopus 로고    scopus 로고
    • An open design, multicentre, randomized trial of percutaneous transluminal coronary angioplasty versus stenting, with a heparin-coated stent, of totally occluded coronary arteries: Rationale, trial design and baseline patient characteristics
    • V. Dzavik, R.G. Carere, K.K. Teo, M.L. Knudtson, J.F. Marquis, C.E. Buller An open design, multicentre, randomized trial of percutaneous transluminal coronary angioplasty versus stenting, with a heparin-coated stent, of totally occluded coronary arteries rationale, trial design and baseline patient characteristics Total Occlusion Study of Canada (TOSCA) Investigators. Can J Cardiol 14 1998 825 832
    • (1998) Total Occlusion Study of Canada (TOSCA) Investigators. Can J Cardiol , vol.14 , pp. 825-832
    • Dzavik, V.1    Carere, R.G.2    Teo, K.K.3    Knudtson, M.L.4    Marquis, J.F.5    Buller, C.E.6
  • 20
    • 0029844755 scopus 로고    scopus 로고
    • Quantitative analysis of heparin retention on heparin bonded knitted Dacron grafts after exposure to sheer stress in vitro
    • P. Swartbol, L. Norgren Quantitative analysis of heparin retention on heparin bonded knitted Dacron grafts after exposure to sheer stress in vitro Int Angiol 15 1996 232 235
    • (1996) Int Angiol , vol.15 , pp. 232-235
    • Swartbol, P.1    Norgren, L.2
  • 21
    • 0037366542 scopus 로고    scopus 로고
    • Fluoropolymer coated Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: A multicentre trial
    • Australian and New Zealand Femoropopliteal Graft Trial Participants J.P.
    • B.I. Robinson, J.P. Fletcher Australian and New Zealand Femoropopliteal Graft Trial Participants Fluoropolymer coated Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting a multicentre trial ANZ J Surg 73 2003 95 99
    • (2003) ANZ J Surg , vol.73 , pp. 95-99
    • Robinson, B.I.1    Fletcher2
  • 22
    • 0037219352 scopus 로고    scopus 로고
    • Subacute stent thrombosis associated with a heparin-coated stent and heparin-induced thrombocytopenia
    • D. Cruz, R. Karlsberg, Y. Takano, D. Vora, J. Tobis Subacute stent thrombosis associated with a heparin-coated stent and heparin-induced thrombocytopenia Catheter Cardiovasc Interv 58 2003 80 83
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 80-83
    • Cruz, D.1    Karlsberg, R.2    Takano, Y.3    Vora, D.4    Tobis, J.5
  • 23
    • 0037219189 scopus 로고    scopus 로고
    • Heparin-coated stent and heparin-induced thrombocytopenia: True, true, and conceivably related
    • J.A. Bittl Heparin-coated stent and heparin-induced thrombocytopenia true, true, and conceivably related Catheter Cardiovasc Interv 58 2003 84 85
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 84-85
    • Bittl, J.A.1
  • 24
    • 0038410135 scopus 로고    scopus 로고
    • Meta-analysis of polytetrafluoroethylene bypass grafts to infrapopliteal arteries
    • M. Albers, V.M. Battistella, M. Romiti, A.A. Rodrigues, C.A. Pereira Meta-analysis of polytetrafluoroethylene bypass grafts to infrapopliteal arteries J Vasc Surg 37 2003 1263 1269
    • (2003) J Vasc Surg , vol.37 , pp. 1263-1269
    • Albers, M.1    Battistella, V.M.2    Romiti, M.3    Rodrigues, A.A.4    Pereira, C.A.5
  • 25
    • 0030701944 scopus 로고    scopus 로고
    • Prospective randomized study of carbon-impregnated polytetrafluoroethylene grafts for below-knee popliteal and distal bypass: Results at 2 years
    • Association Universitaire de Recherche en Chirugie F.
    • F. Bacourt Association Universitaire de Recherche en Chirugie Prospective randomized study of carbon-impregnated polytetrafluoroethylene grafts for below-knee popliteal and distal bypass results at 2 years Ann Vasc Surg 11 1997 596 603
    • (1997) Ann Vasc Surg , vol.11 , pp. 596-603
    • Bacourt1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.