메뉴 건너뛰기




Volumn 25, Issue 1, 2009, Pages 277-285

Design and characterization of a microfluidic packed bed system for protein breakthrough and dynamic binding capacity determination

Author keywords

Ion exchange; Microfluidic; Protein breakthrough

Indexed keywords

ADSORPTION PROFILES; BIO-PHARMACEUTICAL INDUSTRIES; BREAK THROUGH CURVES; CARTESIAN GEOMETRIES; CHROMATOGRAPHY COLUMNS; CIRCULAR CROSS SECTIONS; CURRENT PRACTICES; DYNAMIC BINDING CAPACITIES; FABRICATION TECHNIQUES; GLASS CHIPS; ION EXCHANGE CHROMATOGRAPHIES; ISOCRATIC; ISOTROPIC ETCHINGS; LABELED PROTEINS; MEAN DIAMETERS; MICROCOLUMN; MICROFLUIDIC PROCESS; MICROSCOPIC TECHNIQUES; MOBILE-PHASE VELOCITIES; NARROW CHANNELS; POROUS AGAROSE BEADS; PROOF OF PRINCIPLES; PROTEIN BINDINGS; STANDARD VALUES; VOIDAGE;

EID: 64549104303     PISSN: 87567938     EISSN: None     Source Type: Journal    
DOI: 10.1002/btpr.99     Document Type: Article
Times cited : (31)

References (29)
  • 1
    • 0038064085 scopus 로고    scopus 로고
    • Large-scale ion-exchange column chromatography of proteins-comparison of different formats
    • Levison PR. Large-scale ion-exchange column chromatography of proteins-comparison of different formats. J Chromatogr B. 2003;790:17-33.
    • (2003) J Chromatogr B , vol.790 , pp. 17-33
    • Levison, P.R.1
  • 4
  • 5
    • 34249873258 scopus 로고    scopus 로고
    • An automated microscale chromatography purification of virus-like particles as a strategy for process development
    • Wenger MD, DePhillips P, Price CE, Bracewell DG. An automated microscale chromatography purification of virus-like particles as a strategy for process development. Biotechnol Appl Biochem. 2007;47:131-139.
    • (2007) Biotechnol Appl Biochem , vol.47 , pp. 131-139
    • Wenger, M.D.1    DePhillips, P.2    Price, C.E.3    Bracewell, D.G.4
  • 6
    • 23844431954 scopus 로고    scopus 로고
    • Effect of ionic strength on lysozyme uptake rates in cation exchangers. I. Uptake in SP Sepharose FF
    • Dziennik SR, Belcher EB, Barker GA, Lenhoff AM. Effect of ionic strength on lysozyme uptake rates in cation exchangers. I. Uptake in SP Sepharose FF. Biotechnol Bioeng. 2005;91:139-153.
    • (2005) Biotechnol Bioeng , vol.91 , pp. 139-153
    • Dziennik, S.R.1    Belcher, E.B.2    Barker, G.A.3    Lenhoff, A.M.4
  • 8
    • 0348014631 scopus 로고    scopus 로고
    • On-chip hydrodynamic chromatography separation and detection of nanoparticles and biomolecules
    • Blom MT, Chmela E, Oosterbroek RE, Tijssen R, van der Berg A. On-chip hydrodynamic chromatography separation and detection of nanoparticles and biomolecules. Anal Chem. 2003;75:6761-6768.
    • (2003) Anal Chem , vol.75 , pp. 6761-6768
    • Blom, M.T.1    Chmela, E.2    Oosterbroek, R.E.3    Tijssen, R.4    van der Berg, A.5
  • 9
    • 0037435903 scopus 로고    scopus 로고
    • Experimental Van Deemter plots of shear-driven liquid chromatographic separations in disposable microchannels
    • Vervoot N, Clicq D, Baron GV, Desmet G. Experimental Van Deemter plots of shear-driven liquid chromatographic separations in disposable microchannels. J Chromatogr A. 2003;987:39-48.
    • (2003) J Chromatogr A , vol.987 , pp. 39-48
    • Vervoot, N.1    Clicq, D.2    Baron, G.V.3    Desmet, G.4
  • 10
    • 0035356209 scopus 로고    scopus 로고
    • Two dimensional electrochromatography/capillary electrophoresis on a microchip
    • Gottschlich N, Jacobson SC, Culbertson CT, Ramsey JM. Two dimensional electrochromatography/capillary electrophoresis on a microchip. Anal Chem. 2001;73:2669-2674.
    • (2001) Anal Chem , vol.73 , pp. 2669-2674
    • Gottschlich, N.1    Jacobson, S.C.2    Culbertson, C.T.3    Ramsey, J.M.4
  • 14
    • 0033059825 scopus 로고    scopus 로고
    • Molded rigid monlithic porous polymers: An inexpensive, efficient and versatile alternative to beads for the design of materials for numerous applications
    • Svec F, Fréchet JMJ. Molded rigid monlithic porous polymers: an inexpensive, efficient and versatile alternative to beads for the design of materials for numerous applications. Ind Eng Chem Res. 1999;38:34-18.
    • (1999) Ind Eng Chem Res , vol.38 , pp. 34-18
    • Svec, F.1    Fréchet, J.M.J.2
  • 16
    • 0036468630 scopus 로고    scopus 로고
    • An integrated fritless column for on-chip capillary electrochromatography with conventional stationary phases
    • Ceriotti L, de Rooij NF, Verpoorte E. An integrated fritless column for on-chip capillary electrochromatography with conventional stationary phases. Anal Chem. 2002;74:639-647.
    • (2002) Anal Chem , vol.74 , pp. 639-647
    • Ceriotti, L.1    de Rooij, N.F.2    Verpoorte, E.3
  • 21
    • 33745943608 scopus 로고    scopus 로고
    • Effect of fouling on the capacity and breakthrough characteristics of a packed bed ion exchange chromatography column
    • Sin SC, Baldascini H, Hearle DC, Hoare M, Titchener-Hooker NJ. Effect of fouling on the capacity and breakthrough characteristics of a packed bed ion exchange chromatography column. Bioprocess Biosyst Eng. 2006;28:405-414.
    • (2006) Bioprocess Biosyst Eng , vol.28 , pp. 405-414
    • Sin, S.C.1    Baldascini, H.2    Hearle, D.C.3    Hoare, M.4    Titchener-Hooker, N.J.5
  • 23
    • 0034705635 scopus 로고    scopus 로고
    • Pore size distributions of cation-exchange adsorbents determined by inverse size-exclusion chromatography
    • Dephillips P, Lenhoff AM. Pore size distributions of cation-exchange adsorbents determined by inverse size-exclusion chromatography. J Chromatogr A. 2000;883:39-54.
    • (2000) J Chromatogr A , vol.883 , pp. 39-54
    • Dephillips, P.1    Lenhoff, A.M.2
  • 25
    • 0025008830 scopus 로고
    • Modelling single-component protein adsorption to the cation exchanger S Sepharose FF
    • Skidmore GI, Horstmann BJ, Chase HA. Modelling single-component protein adsorption to the cation exchanger S Sepharose FF. J Chromatogr. 1990;498:113-128.
    • (1990) J Chromatogr , vol.498 , pp. 113-128
    • Skidmore, G.I.1    Horstmann, B.J.2    Chase, H.A.3
  • 26
    • 0031180080 scopus 로고    scopus 로고
    • Modelling of protein adsorption in a fixed-bed: Single and two-solute breakthrough behaviour
    • Hashim MA, Chu KH, Tsan PS. Modelling of protein adsorption in a fixed-bed: single and two-solute breakthrough behaviour. Chem Eng Commun. 1997;161:45-63.
    • (1997) Chem Eng Commun , vol.161 , pp. 45-63
    • Hashim, M.A.1    Chu, K.H.2    Tsan, P.S.3
  • 28
    • 0032512777 scopus 로고    scopus 로고
    • Frontal chromatography of proteins effect of axial dispersion on column performance
    • Heeter GA, Liapis AI. Frontal chromatography of proteins effect of axial dispersion on column performance. J Chromatogr A. 1998;796:157-164.
    • (1998) J Chromatogr A , vol.796 , pp. 157-164
    • Heeter, G.A.1    Liapis, A.I.2
  • 29
    • 27544475970 scopus 로고    scopus 로고
    • When microfluidic devices go bad-how does fouling occur in microfluidic devices, and what can be done about it?
    • Mukhopadhyay R. When microfluidic devices go bad-how does fouling occur in microfluidic devices, and what can be done about it? Anal Chem. 2005;77:429A-432A.
    • (2005) Anal Chem , vol.77
    • Mukhopadhyay, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.