메뉴 건너뛰기




Volumn 33, Issue 2, 2009, Pages 543-547

Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE PLATE; CADAVER; CLINICAL ARTICLE; HUMAN; HUMERUS; HUMERUS FRACTURE; MINIMALLY INVASIVE PERCUTANEOUS PLATE OSTEOSYNTHESIS TECHNIQUE; PRIORITY JOURNAL; SURGICAL TECHNIQUE; TREATMENT OUTCOME;

EID: 64249144191     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-008-0522-2     Document Type: Article
Times cited : (57)

References (17)
  • 1
    • 14744300697 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects. A new technique of bone transport: A report of two cases
    • T Apivatthakakul O Arpornchayanon 2005 Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects. A new technique of bone transport: a report of two cases Injury 36 4 530 538
    • (2005) Injury , vol.36 , Issue.4 , pp. 530-538
    • Apivatthakakul, T.1    Arpornchayanon, O.2
  • 2
    • 0036107691 scopus 로고    scopus 로고
    • The principle of helical implants. Unusual ideas worth considering
    • Fernandez Dell Oca AA (2002) The principle of helical implants. Unusual ideas worth considering. Injury Suppl 33:19-27
    • (2002) Injury Suppl , vol.33 , pp. 19-27
    • Fernandez Dell Oca, A.A.1
  • 3
    • 10644243673 scopus 로고    scopus 로고
    • Locking compression plate (LCP): An osteosynthesis plate based on the dynamic compression plate and point contact fixator (PCFix)
    • R Frigg 2001 Locking compression plate (LCP): an osteosynthesis plate based on the dynamic compression plate and point contact fixator (PCFix) Injury 32 Suppl 2 636
    • (2001) Injury , vol.32 , Issue.SUPPL 2 , pp. 636
    • Frigg, R.1
  • 4
    • 0242657313 scopus 로고    scopus 로고
    • Development of the locking compression plate
    • R Frigg 2003 Development of the locking compression plate Injury 34 Suppl 2 B6 B10
    • (2003) Injury , vol.34 , Issue.SUPPL 2
    • Frigg, R.1
  • 5
    • 0030472909 scopus 로고    scopus 로고
    • Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve
    • M Gerwin RN Hotchkiss AJ Weiland 1996 Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve J Bone Joint Surg Am 78-A 1690 1695
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1690-1695
    • Gerwin, M.1    Hotchkiss, R.N.2    Weiland, A.J.3
  • 6
    • 0027296544 scopus 로고
    • Surgical treatment of humeral shaft fracture: The Basel experience
    • D Heim F Herkert P Hess P Regazzni 1993 Surgical treatment of humeral shaft fracture: the Basel experience J Trauma 35 22632
    • (1993) J Trauma , vol.35 , pp. 22632
    • Heim, D.1    Herkert, F.2    Hess, P.3    Regazzni, P.4
  • 7
    • 0023281051 scopus 로고
    • Severely comminuted femoral shaft fracture: Treatment by bridging plate osteosynthesis
    • U Heitemeyer F Kemper G Hierholzer J Haines 1987 Severely comminuted femoral shaft fracture: treatment by bridging plate osteosynthesis Arch Orthop Trauma Surg 106 327 330
    • (1987) Arch Orthop Trauma Surg , vol.106 , pp. 327-330
    • Heitemeyer, U.1    Kemper, F.2    Hierholzer, G.3    Haines, J.4
  • 8
    • 0031452816 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis of distal fractures of the tibia
    • DL Helfet PY Shonnard D Levine J Borrelli Jr 1997 Minimally invasive plate osteosynthesis of distal fractures of the tibia Injury 28 Suppl 1 428
    • (1997) Injury , vol.28 , Issue.SUPPL 1 , pp. 428
    • Helfet, D.L.1    Shonnard, P.Y.2    Levine, D.3    Borrelli Jr, J.4
  • 10
    • 64249100708 scopus 로고    scopus 로고
    • Anatomic analysis of MIPPO technique in treatment of humeral fractures: A preliminary clinic report
    • Fang Ji Tie-yi Yang Ming-chun Wang 2005 Anatomic analysis of MIPPO technique in treatment of humeral fractures: a preliminary clinic report Chinese J Orthop Trauma 7 12 1128 1131
    • (2005) Chinese J Orthop Trauma , vol.7 , Issue.12 , pp. 1128-1131
    • Fang, J.1    Tie-Yi, Y.2    Ming-Chun, W.3
  • 11
    • 35348908986 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture
    • TW Lau F Leung CF Chan SP Chow 2007 Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture Int Orthop 31 5 657 664
    • (2007) Int Orthop , vol.31 , Issue.5 , pp. 657-664
    • Lau, T.W.1    Leung, F.2    Chan, C.F.3    Chow, S.P.4
  • 12
    • 19044377858 scopus 로고    scopus 로고
    • The technology of minimally invasive percutaneous osteosynthesis (MIPO)
    • SM Perren 2002 The technology of minimally invasive percutaneous osteosynthesis (MIPO) Injury 33 Suppl 1 VI VII
    • (2002) Injury , vol.33 , Issue.SUPPL 1
    • Perren, S.M.1
  • 13
    • 0036854433 scopus 로고    scopus 로고
    • Evolution of the internal fixation of long bone fractures. the scientific basis of biological internal fixation: Choosing a new balance between stability and biology
    • SM Perren 2002 Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology J Bone Joint Surg Br 84 8 1093 1110
    • (2002) J Bone Joint Surg Br , vol.84 , Issue.8 , pp. 1093-1110
    • Perren, S.M.1
  • 14
    • 0142168925 scopus 로고    scopus 로고
    • Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?
    • K Stoffel U Dieter G Stachowiak A Gachter MS Kuster 2003 Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled? Injury 34 Suppl 2 B11 B19
    • (2003) Injury , vol.34 , Issue.SUPPL 2
    • Stoffel, K.1    Dieter, U.2    Stachowiak, G.3    Gachter, A.4    Kuster, M.S.5
  • 15
    • 0142199888 scopus 로고    scopus 로고
    • General principles for the clinical use of the LCP
    • M Wagner 2003 General principles for the clinical use of the LCP Injury 34 Suppl 2 B31 B42
    • (2003) Injury , vol.34 , Issue.SUPPL 2
    • Wagner, M.1
  • 16
    • 16644403465 scopus 로고    scopus 로고
    • New concepts for bone fracture treatment and the locking compression plate
    • M Wagner A Frenk R Frigg 2004 New concepts for bone fracture treatment and the locking compression plate Surg Technol Int 12 271 277
    • (2004) Surg Technol Int , vol.12 , pp. 271-277
    • Wagner, M.1    Frenk, A.2    Frigg, R.3
  • 17
    • 35148886200 scopus 로고    scopus 로고
    • Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures
    • A Zhiquan Z Bingfang W Yeming Z Chi H Peiyan 2007 Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures J Orthop Trauma 21 9 628 633
    • (2007) J Orthop Trauma , vol.21 , Issue.9 , pp. 628-633
    • Zhiquan, A.1    Bingfang, Z.2    Yeming, W.3    Chi, Z.4    Peiyan, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.