메뉴 건너뛰기




Volumn 36, Issue 3, 2009, Pages 209-219

In vitro validation of a Pitot-based flow meter for the measurement of respiratory volume and flow in large animal anaesthesia

Author keywords

Anaesthesia; Large animals; Monitoring; Spirometry; Ventilation

Indexed keywords

ANIMALIA;

EID: 64149107778     PISSN: 14672987     EISSN: 14672995     Source Type: Journal    
DOI: 10.1111/j.1467-2995.2009.00449.x     Document Type: Article
Times cited : (28)

References (20)
  • 1
    • 0027440943 scopus 로고
    • Continuous spirometry: An aid to monitoring ventilation during operation
    • Bardoczky G, Engelman E, D'Hollander A (1993) Continuous spirometry: an aid to monitoring ventilation during operation. Br J Anaesth 71, 747 751.
    • (1993) Br J Anaesth , vol.71 , pp. 747-751
    • Bardoczky, G.1    Engelman, E.2    D'Hollander, A.3
  • 2
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland M, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet I, 307 310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, M.1    Altman, D.2
  • 3
    • 0022765176 scopus 로고
    • Design and construction of a pulsed ultrasonic air flowmeter
    • Buess C, Pietsch P, Guggenbühl W et al. (1986) Design and construction of a pulsed ultrasonic air flowmeter. IEEE Trans Biomed Eng 8, 768 774.
    • (1986) IEEE Trans Biomed Eng , vol.8 , pp. 768-774
    • Buess, C.1    Pietsch, P.2    Guggenbühl, W.3
  • 5
    • 18444366764 scopus 로고    scopus 로고
    • Isoflurane-measurement error using short wavelength infrared techniques in horses: Influence of fresh gas flow and pre-anaesthetic food deprivation
    • Dujardin C, Gootjes P, Moens Y (2006) Isoflurane-measurement error using short wavelength infrared techniques in horses: influence of fresh gas flow and pre-anaesthetic food deprivation. Vet Anaesth Analg 32, 101 106.
    • (2006) Vet Anaesth Analg , vol.32 , pp. 101-106
    • Dujardin, C.1    Gootjes, P.2    Moens, Y.3
  • 6
    • 0032934208 scopus 로고    scopus 로고
    • Effects of xenon on the performance of various respiratory flowmeters
    • Goto T, Saito H, Nakata Y et al. (1999) Effects of xenon on the performance of various respiratory flowmeters. Anesthesiology 90, 555 563.
    • (1999) Anesthesiology , vol.90 , pp. 555-563
    • Goto, T.1    Saito, H.2    Nakata, Y.3
  • 7
    • 0034788996 scopus 로고    scopus 로고
    • Viscosity and density of common anaesthetic gases: Implications for flow measurements
    • Habre W, Asztalos T, Sly PD et al. (2001) Viscosity and density of common anaesthetic gases: implications for flow measurements. Br J Anaesth 87, 602 607.
    • (2001) Br J Anaesth , vol.87 , pp. 602-607
    • Habre, W.1    Asztalos, T.2    Sly, P.D.3
  • 8
    • 64149121542 scopus 로고    scopus 로고
    • Monitoring the respiratory system
    • In. Hall, L.W. Clarke, K.W. Trim, C.W. eds. WB Saunders. London, UK. pp. 48.
    • Hall LW, Clarke KW, Trim CW (2001) Monitoring the respiratory system. In : Veterinary Anaesthesia 10th edn). Hall LW, Clarke KW, Trim CW (eds. WB Saunders, London, UK, pp. 48.
    • (2001) Veterinary Anaesthesia10th Edn).
    • Hall, L.W.1    Clarke, K.W.2    Trim, C.W.3
  • 9
    • 0014152565 scopus 로고
    • A comparison of methods of calibrating the pneumotachograph
    • Hobbes AFT (1967) A comparison of methods of calibrating the pneumotachograph. Br J Anaesth 39, 899 906.
    • (1967) Br J Anaesth , vol.39 , pp. 899-906
    • Hobbes, A.F.T.1
  • 10
    • 64149120033 scopus 로고
    • Monitoring ventilation and compliance with side stream spirometry
    • Hufmann LM (1991) Monitoring ventilation and compliance with side stream spirometry. AANA Journal 60, 217 220.
    • (1991) AANA Journal , vol.60 , pp. 217-220
    • Hufmann, L.M.1
  • 13
    • 0018863291 scopus 로고
    • Gas viscosity effects in anesthesia
    • Jones CS (1980) Gas viscosity effects in anesthesia. Anesth Analg 59, 192 196.
    • (1980) Anesth Analg , vol.59 , pp. 192-196
    • Jones, C.S.1
  • 14
    • 0342699809 scopus 로고    scopus 로고
    • Comparison of the performance of linear resistance and ultrasonic pneumotachometers at rest and during lobeline-induced hyperpnoea
    • Kästner SBR, Marlin DJ, Roberts CA et al. (2000) Comparison of the performance of linear resistance and ultrasonic pneumotachometers at rest and during lobeline-induced hyperpnoea. Res Vet Sci 68, 153 159.
    • (2000) Res Vet Sci , vol.68 , pp. 153-159
    • Kästner, S.B.R.1    Marlin, D.J.2    Roberts, C.A.3
  • 15
    • 0027377991 scopus 로고
    • A novel sensor for routine continuous spirometry of intubated patients
    • Meriläinen P, Hänninen H, Tuomaala L (1993) A novel sensor for routine continuous spirometry of intubated patients. J Clin Monit 9, 374 380.
    • (1993) J Clin Monit , vol.9 , pp. 374-380
    • Meriläinen, P.1    Hänninen, H.2    Tuomaala, L.3
  • 16
    • 1442292158 scopus 로고
    • The influence of methane on the infrared measurement of halothane in the horse
    • Moens Y, Gootjes P, Lagerweij E (1991) The influence of methane on the infrared measurement of halothane in the horse. J vet Anaesth 18, 4 7.
    • (1991) J Vet Anaesth , vol.18 , pp. 4-7
    • Moens, Y.1    Gootjes, P.2    Lagerweij, E.3
  • 19
    • 64149122092 scopus 로고
    • Pneumotachography
    • In. University Press. Leiden, The Netherlands. pp.
    • Rolly G, Renders-Versichelen L (1974) Pneumotachography. In : Measurement in Anaesthesia. University Press, Leiden, The Netherlands, pp. 88 99.
    • (1974) Measurement in Anaesthesia. , pp. 88-99
    • Rolly, G.1    Renders-Versichelen, L.2
  • 20
    • 0032399620 scopus 로고    scopus 로고
    • Monitoring during anaesthesia: Techniques and interpretation
    • Trim CM (1998) Monitoring during anaesthesia: techniques and interpretation. Equine vet Educ 10, 207 218.
    • (1998) Equine Vet Educ , vol.10 , pp. 207-218
    • Trim, C.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.