메뉴 건너뛰기




Volumn 22, Issue 2, 2009, Pages 179-183

Novel technique for 14 French arteriotomy closure after percutaneous aortic valvuloplasty using twomynx closure devices

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ANAMNESIS; ANGIOGRAPHY; AORTA STENOSIS; AORTIC VALVE REPAIR; ARTERIOTOMY; ARTICLE; CASE REPORT; CLINICAL FEATURE; DEVICE; FEMALE; FLUOROSCOPY; HUMAN; MALE; MYNX DEVICE; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 64149085020     PISSN: 08964327     EISSN: 15408183     Source Type: Journal    
DOI: 10.1111/j.1540-8183.2008.00402.x     Document Type: Article
Times cited : (6)

References (7)
  • 1
    • 0025750768 scopus 로고
    • Acute and 30-day follow-up results in 674 patients from the NHLBI balloon valvuloplasty registry
    • Percutaneous balloon aortic valvuloplasty.
    • Percutaneous balloon aortic valvuloplasty. Acute and 30-day follow-up results in 674 patients from the NHLBI balloon valvuloplasty registry. Circulation 1991 84 : 2383 2397.
    • (1991) Circulation , vol.84 , pp. 2383-2397
  • 2
    • 33846144407 scopus 로고    scopus 로고
    • Current results of balloon aortic valvuloplasty in high-risk patients
    • Shareghi S, Rasouli L, Shavelle DM, et al. Current results of balloon aortic valvuloplasty in high-risk patients. J Invasive Cardiol 2007 19 : 1 5.
    • (2007) J Invasive Cardiol , vol.19 , pp. 1-5
    • Shareghi, S.1    Rasouli, L.2    Shavelle, D.M.3
  • 3
    • 0034266031 scopus 로고    scopus 로고
    • Access site management after aortic valvuloplasty using a suture mediated closure device: Clinical experience in 4 cases
    • Marchant D, Schwartz R, Chepurko L, et al. Access site management after aortic valvuloplasty using a suture mediated closure device: Clinical experience in 4 cases. J Invasive Cardiol 2000 12 : 474 477.
    • (2000) J Invasive Cardiol , vol.12 , pp. 474-477
    • Marchant, D.1    Schwartz, R.2    Chepurko, L.3
  • 4
    • 0034899051 scopus 로고    scopus 로고
    • Use of a percutaneous arterial suture device (Perclose) in patients undergoing percutaneous balloon aortic valvuloplasty
    • Michaels AD, Ports TA. Use of a percutaneous arterial suture device (Perclose) in patients undergoing percutaneous balloon aortic valvuloplasty. Catheter Cardiovasc Interv 2001 53 : 445 447.
    • (2001) Catheter Cardiovasc Interv , vol.53 , pp. 445-447
    • Michaels, A.D.1    Ports, T.A.2
  • 5
    • 0035430153 scopus 로고    scopus 로고
    • Percutaneous suture closure for management of large French size arterial puncture in aortic valvuloplasty
    • Solomon LW, Fusman B, Jolly N, et al. Percutaneous suture closure for management of large French size arterial puncture in aortic valvuloplasty. J Invasive Cardiol 2001 13 : 592 596.
    • (2001) J Invasive Cardiol , vol.13 , pp. 592-596
    • Solomon, L.W.1    Fusman, B.2    Jolly, N.3
  • 6
    • 64149123868 scopus 로고    scopus 로고
    • The Mynx (TM) Vascular Closure Device
    • Ansel GM, Garasic JM. The Mynx (TM) Vascular Closure Device. Endovasc Today 2008 : 23 28.
    • (2008) Endovasc Today , pp. 23-28
    • Ansel, G.M.1    Garasic, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.