-
1
-
-
1242284991
-
Theoretical and Experimental Prospects for Protein Identification Based Solely on Accurate Mass Measurement
-
He F., Emmett M.R., Hakansson K., Hendrickson C.L., and Marshall A.G. Theoretical and Experimental Prospects for Protein Identification Based Solely on Accurate Mass Measurement. J. Proteome Res. 3 (2004) 61-67
-
(2004)
J. Proteome Res.
, vol.3
, pp. 61-67
-
-
He, F.1
Emmett, M.R.2
Hakansson, K.3
Hendrickson, C.L.4
Marshall, A.G.5
-
2
-
-
0033565832
-
Role of Accurate Mass Measurement (±10 ppm) in Protein Identification Strategies Employing MS or MS/MS and Database Searching
-
Clauser K.R., Baker P., and Burlingame A.L. Role of Accurate Mass Measurement (±10 ppm) in Protein Identification Strategies Employing MS or MS/MS and Database Searching. Anal. Chem. 71 (1999) 2871-2882
-
(1999)
Anal. Chem.
, vol.71
, pp. 2871-2882
-
-
Clauser, K.R.1
Baker, P.2
Burlingame, A.L.3
-
3
-
-
0001268221
-
Fourier Transform Ion Cyclotron Resonance Spectroscopy
-
Comisarow M.B., and Marshall A.G. Fourier Transform Ion Cyclotron Resonance Spectroscopy. Chem. Phys. Lett. 25 (1974) 282-283
-
(1974)
Chem. Phys. Lett.
, vol.25
, pp. 282-283
-
-
Comisarow, M.B.1
Marshall, A.G.2
-
4
-
-
49549153202
-
Frequency-Sweep Fourier Transform Ion Cyclotron Resonance Spectroscopy
-
Comisarow M.B., and Marshall A.G. Frequency-Sweep Fourier Transform Ion Cyclotron Resonance Spectroscopy. Chem. Phys. Lett. 26 (1974) 489-490
-
(1974)
Chem. Phys. Lett.
, vol.26
, pp. 489-490
-
-
Comisarow, M.B.1
Marshall, A.G.2
-
5
-
-
0030461690
-
Fourier Transform Mass Spectrometry
-
Amster I.J. Fourier Transform Mass Spectrometry. J. Mass Spectrom. 31 (1996) 1325-1337
-
(1996)
J. Mass Spectrom.
, vol.31
, pp. 1325-1337
-
-
Amster, I.J.1
-
6
-
-
0035253342
-
Baseline Mass Resolution of Peptide Isobars: A Record for Molecular Mass Resolution
-
He F., Hendrickson C.L., and Marshall A.G. Baseline Mass Resolution of Peptide Isobars: A Record for Molecular Mass Resolution. Anal. Chem. 73 (2001) 647-650
-
(2001)
Anal. Chem.
, vol.73
, pp. 647-650
-
-
He, F.1
Hendrickson, C.L.2
Marshall, A.G.3
-
7
-
-
34447338368
-
Parts-per-Billion Mass Measurement Accuracy Achieved through the Combination of Multiple Linear Regression and Automatic Gain Control in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
-
Williams Jr. D.K., and Muddiman D.C. Parts-per-Billion Mass Measurement Accuracy Achieved through the Combination of Multiple Linear Regression and Automatic Gain Control in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer. Anal. Chem. 79 (2007) 5058-5063
-
(2007)
Anal. Chem.
, vol.79
, pp. 5058-5063
-
-
Williams Jr., D.K.1
Muddiman, D.C.2
-
8
-
-
0032578463
-
Counting Individual Sulfur Atoms in a Protein by Ultrahigh-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Experimental Resolution of Isotopic Fine Structure in Proteins
-
Shi S.D.H., Hendrickson C.L., and Marshall A.G. Counting Individual Sulfur Atoms in a Protein by Ultrahigh-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Experimental Resolution of Isotopic Fine Structure in Proteins. Proc. Natl. Acad. Sci. U. S. A. 95 (1998) 11532-11537
-
(1998)
Proc. Natl. Acad. Sci. U. S. A.
, vol.95
, pp. 11532-11537
-
-
Shi, S.D.H.1
Hendrickson, C.L.2
Marshall, A.G.3
-
9
-
-
0033591076
-
Techview: Biochemistry, Biomolecule Mass Spectrometry
-
McLafferty F.W., Fridriksson E.K., Horn D.M., Lewis M.A., and Zubarev R.A. Techview: Biochemistry, Biomolecule Mass Spectrometry. Science 284 (1999) 1289-1290
-
(1999)
Science
, vol.284
, pp. 1289-1290
-
-
McLafferty, F.W.1
Fridriksson, E.K.2
Horn, D.M.3
Lewis, M.A.4
Zubarev, R.A.5
-
10
-
-
0037103713
-
Resolution of 11,000 Compositionally Distinct Components in a Single Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrum of Crude Oil
-
Hughey C.A., Rodgers R.P., and Marshall A.G. Resolution of 11,000 Compositionally Distinct Components in a Single Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrum of Crude Oil. Anal. Chem. 74 (2002) 4145-4149
-
(2002)
Anal. Chem.
, vol.74
, pp. 4145-4149
-
-
Hughey, C.A.1
Rodgers, R.P.2
Marshall, A.G.3
-
11
-
-
0036535032
-
Fourier Transform Ion Cyclotron Resonance Detection: Principles and Experimental Configurations
-
Marshall A.G., and Hendrickson C.L. Fourier Transform Ion Cyclotron Resonance Detection: Principles and Experimental Configurations. Int. J. Mass Spectrom. 215 (2002) 59-75
-
(2002)
Int. J. Mass Spectrom.
, vol.215
, pp. 59-75
-
-
Marshall, A.G.1
Hendrickson, C.L.2
-
13
-
-
33847802723
-
Proposed Method for Mass Spectrometric Analysis for Ultra-Low Vapor Pressure Compounds
-
McIver Jr. R.T., Ledford Jr. E.B., and Miller J.S. Proposed Method for Mass Spectrometric Analysis for Ultra-Low Vapor Pressure Compounds. Anal. Chem. 47 (1975) 692-697
-
(1975)
Anal. Chem.
, vol.47
, pp. 692-697
-
-
McIver Jr., R.T.1
Ledford Jr., E.B.2
Miller, J.S.3
-
14
-
-
0033392170
-
Realistic Simulation of the Ion Cyclotron Resonance Mass Spectrometer Using a Distributed Three-Dimensional Particle-in-Cell Code
-
Mitchell D.W. Realistic Simulation of the Ion Cyclotron Resonance Mass Spectrometer Using a Distributed Three-Dimensional Particle-in-Cell Code. J. Am. Soc. Mass Spectromy. 10 (1999) 136-152
-
(1999)
J. Am. Soc. Mass Spectromy.
, vol.10
, pp. 136-152
-
-
Mitchell, D.W.1
-
15
-
-
0029679968
-
Prediction of a Space Charge Induced Upper Molecular Mass Limit Towards Achieving Unit Mass Resolution in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Mitchell D.W., and Smith R.D. Prediction of a Space Charge Induced Upper Molecular Mass Limit Towards Achieving Unit Mass Resolution in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Mass Spectrom. 31 (1996) 771-790
-
(1996)
J. Mass Spectrom.
, vol.31
, pp. 771-790
-
-
Mitchell, D.W.1
Smith, R.D.2
-
16
-
-
0030468505
-
Advantages of High Magnetic Field for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Marshall A.G., and Guan S. Advantages of High Magnetic Field for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Rapid Commun. Mass Spectrom. 10 (1996) 1819-1823
-
(1996)
Rapid Commun. Mass Spectrom.
, vol.10
, pp. 1819-1823
-
-
Marshall, A.G.1
Guan, S.2
-
17
-
-
44949150382
-
High-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla
-
Schaub T.M., Hendrickson C.L., Horning S., Quinn J.P., Senko M.W., and Marshall A.G. High-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla. Anal. Chem. 80 (2008) 3985-3990
-
(2008)
Anal. Chem.
, vol.80
, pp. 3985-3990
-
-
Schaub, T.M.1
Hendrickson, C.L.2
Horning, S.3
Quinn, J.P.4
Senko, M.W.5
Marshall, A.G.6
-
18
-
-
0001365594
-
Cyclotron Motion of Two Coulombically Interacting Ion Clouds with Implications to Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry
-
Mitchell D.W., and Smith R.D. Cyclotron Motion of Two Coulombically Interacting Ion Clouds with Implications to Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry. Phys. Rev. E Stat. Phys Plasmas Fluids Relat. Interdisc. Topics 52 (1995) 4366-4386
-
(1995)
Phys. Rev. E Stat. Phys Plasmas Fluids Relat. Interdisc. Topics
, vol.52
, pp. 4366-4386
-
-
Mitchell, D.W.1
Smith, R.D.2
-
19
-
-
14744304574
-
Proteomics by FTICR Mass Spectrometry: Top Down and Bottom Up
-
Bogdanov B., and Smith R.D. Proteomics by FTICR Mass Spectrometry: Top Down and Bottom Up. Mass Spectrom. Rev. 24 (2005) 168-200
-
(2005)
Mass Spectrom. Rev.
, vol.24
, pp. 168-200
-
-
Bogdanov, B.1
Smith, R.D.2
-
20
-
-
0033518556
-
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
-
Kelleher N.L., Lin H.Y., Valaskovic G.A., Aaserud D.J., Fridriksson E.K., and McLafferty F.W. Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry. J. Am. Chem. Soc. 121 (1999) 806-812
-
(1999)
J. Am. Chem. Soc.
, vol.121
, pp. 806-812
-
-
Kelleher, N.L.1
Lin, H.Y.2
Valaskovic, G.A.3
Aaserud, D.J.4
Fridriksson, E.K.5
McLafferty, F.W.6
-
21
-
-
0037133237
-
Top-Down Mass Spectrometry of a 29-kDa Protein for Characterization of Any Posttranslational Modification to within One Residue
-
Sze S.K., Ge Y., Oh H., and McLafferty F.W. Top-Down Mass Spectrometry of a 29-kDa Protein for Characterization of Any Posttranslational Modification to within One Residue. Proc. Natl. Acad. Sci. U. S. A. 99 (2002) 1774-1779
-
(2002)
Proc. Natl. Acad. Sci. U. S. A.
, vol.99
, pp. 1774-1779
-
-
Sze, S.K.1
Ge, Y.2
Oh, H.3
McLafferty, F.W.4
-
22
-
-
58149209966
-
Ion Traps for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Principles and Design of Geometric and Electric Configurations
-
Guan S., and Marshall A.G. Ion Traps for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Principles and Design of Geometric and Electric Configurations. Int. J. Mass Spectrom. Ion Process. 146/147 (1995) 261-296
-
(1995)
Int. J. Mass Spectrom. Ion Process.
, vol.146-147
, pp. 261-296
-
-
Guan, S.1
Marshall, A.G.2
-
23
-
-
0028244357
-
Evolution of Trapped Ion Cells in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Anderson J.S., Vartanian H., and Laude D.A. Evolution of Trapped Ion Cells in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Trends Anal. Chem. 13 (1994) 234-239
-
(1994)
Trends Anal. Chem.
, vol.13
, pp. 234-239
-
-
Anderson, J.S.1
Vartanian, H.2
Laude, D.A.3
-
24
-
-
0002897391
-
Advances in Trapped Ion Cells for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Vartanian V.H., Anderson J.S., and Laude D.A. Advances in Trapped Ion Cells for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Mass Spectrom. Rev. 14 (1995) 1-19
-
(1995)
Mass Spectrom. Rev.
, vol.14
, pp. 1-19
-
-
Vartanian, V.H.1
Anderson, J.S.2
Laude, D.A.3
-
25
-
-
84989132905
-
The Infinity Cell: A New Trapped-Ion Cell with Radiofrequency Covered Trapping Electrodes for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Caravatti P., and Allemann M. The Infinity Cell: A New Trapped-Ion Cell with Radiofrequency Covered Trapping Electrodes for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Org. Mass Spectrom. 26 (1991) 514-518
-
(1991)
Org. Mass Spectrom.
, vol.26
, pp. 514-518
-
-
Caravatti, P.1
Allemann, M.2
-
26
-
-
0001321964
-
Elimination of Axial Ejection during Excitation with a Capacitively Coupled Open Trapped-Ion Cell for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Beu S.C., and Laude Jr. D.A. Elimination of Axial Ejection during Excitation with a Capacitively Coupled Open Trapped-Ion Cell for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Anal. Chem. 64 (1992) 177-180
-
(1992)
Anal. Chem.
, vol.64
, pp. 177-180
-
-
Beu, S.C.1
Laude Jr., D.A.2
-
27
-
-
0031239787
-
External Accumulation of Ions for Enhanced Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Senko M.W., Hendrickson C.L., Emmett M.R., Shi S.D.H., and Marshall A.G. External Accumulation of Ions for Enhanced Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Am. Soc. Mass Spectrom. 8 (1997) 970-976
-
(1997)
J. Am. Soc. Mass Spectrom.
, vol.8
, pp. 970-976
-
-
Senko, M.W.1
Hendrickson, C.L.2
Emmett, M.R.3
Shi, S.D.H.4
Marshall, A.G.5
-
28
-
-
0035564255
-
A Dynamic Ion Cooling Technique for FTICR Mass Spectrometry
-
Gorshkov M.V., Masselon C.D., Anderson G.A., Udseth H.R., Harkewicz R., and Smith R.D. A Dynamic Ion Cooling Technique for FTICR Mass Spectrometry. J. Am. Soc. Mass Spectrom. 12 (2001) 1169-1173
-
(2001)
J. Am. Soc. Mass Spectrom.
, vol.12
, pp. 1169-1173
-
-
Gorshkov, M.V.1
Masselon, C.D.2
Anderson, G.A.3
Udseth, H.R.4
Harkewicz, R.5
Smith, R.D.6
-
29
-
-
64049113659
-
-
U.S. Patent 4 924 089
-
Caravatti, P. U.S. Patent 4 924 089, 1990.
-
(1990)
-
-
Caravatti, P.1
-
30
-
-
30844435526
-
A 4.7 Tesla Internal MALDI-FTICR Instrument for High Mass Studies: Performance and Methods
-
Easterling M.L., Pitsenberger C.C., Kulkarni S.S., Taylor P.K., and Amster I.J. A 4.7 Tesla Internal MALDI-FTICR Instrument for High Mass Studies: Performance and Methods. Int. J. Mass Spectrom. Ion Process. 157/158 (1996) 97-113
-
(1996)
Int. J. Mass Spectrom. Ion Process.
, vol.157-158
, pp. 97-113
-
-
Easterling, M.L.1
Pitsenberger, C.C.2
Kulkarni, S.S.3
Taylor, P.K.4
Amster, I.J.5
-
31
-
-
0001106904
-
Minimizing Peak Coalescence: High-Resolution Separation of Isotope Peaks in Partially Deamidated Peptides by Matrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Stults J.T. Minimizing Peak Coalescence: High-Resolution Separation of Isotope Peaks in Partially Deamidated Peptides by Matrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Anal. Chem. 69 (1997) 1815-1819
-
(1997)
Anal. Chem.
, vol.69
, pp. 1815-1819
-
-
Stults, J.T.1
-
32
-
-
0031569138
-
Detection, Number, and Sequence Location of Sulfur-Containing Amino Acids and Disulfide Bridges in Peptides by Ultrahigh-Resolution MALDI FTICR Mass Spectrometry
-
Solouki T., Emmett M.R., Guan S., and Marshall A.G. Detection, Number, and Sequence Location of Sulfur-Containing Amino Acids and Disulfide Bridges in Peptides by Ultrahigh-Resolution MALDI FTICR Mass Spectrometry. Anal. Chem. 69 (1997) 1163-1168
-
(1997)
Anal. Chem.
, vol.69
, pp. 1163-1168
-
-
Solouki, T.1
Emmett, M.R.2
Guan, S.3
Marshall, A.G.4
-
33
-
-
0001200142
-
Evolution of an Ion Cloud in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer during Signal Detection: Its Influence on Spectral Line Shape and Position
-
Nikolaev E.N., Miluchihin N., and Inoue M. Evolution of an Ion Cloud in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer during Signal Detection: Its Influence on Spectral Line Shape and Position. Int. J. Mass Spectrom. Ion Process. 148 (1995) 145-157
-
(1995)
Int. J. Mass Spectrom. Ion Process.
, vol.148
, pp. 145-157
-
-
Nikolaev, E.N.1
Miluchihin, N.2
Inoue, M.3
-
34
-
-
33751004176
-
Sub Part-per-Million Mass Accuracy by Using Stepwise-External Calibration in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Wong R.L., and Amster I.J. Sub Part-per-Million Mass Accuracy by Using Stepwise-External Calibration in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Am. Soc. Mass Spectrom. 17 (2006) 1681-1691
-
(2006)
J. Am. Soc. Mass Spectrom.
, vol.17
, pp. 1681-1691
-
-
Wong, R.L.1
Amster, I.J.2
-
35
-
-
0001246359
-
High-Resolution Accurate Mass Measurements of Biomolecules Using a New Electrospray Ionization Ion Cyclotron Resonance Mass Spectrometer
-
Winger B.E., Hofstadler S.A., Bruce J.E., Udseth H.R., and Smith R.D. High-Resolution Accurate Mass Measurements of Biomolecules Using a New Electrospray Ionization Ion Cyclotron Resonance Mass Spectrometer. J. Am. Soc. Mass Spectrom. 4 (1993) 566-577
-
(1993)
J. Am. Soc. Mass Spectrom.
, vol.4
, pp. 566-577
-
-
Winger, B.E.1
Hofstadler, S.A.2
Bruce, J.E.3
Udseth, H.R.4
Smith, R.D.5
-
36
-
-
0000173772
-
Shrink-Wrapping an Ion Cloud for High-Performance Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Guan S., Kim H.S., Marshall A.G., Wahl M.C., Wood T.D., and Xiang X. Shrink-Wrapping an Ion Cloud for High-Performance Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Chem. Rev. 94 (1994) 2161-2182
-
(1994)
Chem. Rev.
, vol.94
, pp. 2161-2182
-
-
Guan, S.1
Kim, H.S.2
Marshall, A.G.3
Wahl, M.C.4
Wood, T.D.5
Xiang, X.6
-
37
-
-
0000332198
-
Circularly Polarized Quadrature Excitation for Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry
-
Guan S., Gorshkov M.V., and Marshall A.G. Circularly Polarized Quadrature Excitation for Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry. Chem. Phys. Lett. 198 (1992) 143-148
-
(1992)
Chem. Phys. Lett.
, vol.198
, pp. 143-148
-
-
Guan, S.1
Gorshkov, M.V.2
Marshall, A.G.3
-
38
-
-
0038824578
-
Improved Ion Extraction from a Linear Octopole Ion Trap: SIMION Analysis and Experimental Demonstration
-
Wilcox B.E., Hendrickson C.L., and Marshall A.G. Improved Ion Extraction from a Linear Octopole Ion Trap: SIMION Analysis and Experimental Demonstration. J. Am. Soc. Mass Spectrom. 13 (2002) 1304-1312
-
(2002)
J. Am. Soc. Mass Spectrom.
, vol.13
, pp. 1304-1312
-
-
Wilcox, B.E.1
Hendrickson, C.L.2
Marshall, A.G.3
-
39
-
-
31844448971
-
Combining Low and High Mass Ion Accumulation for Enhancing Shotgun Proteome Analysis by Accurate Mass Measurement
-
Wong R.L., and Amster I.J. Combining Low and High Mass Ion Accumulation for Enhancing Shotgun Proteome Analysis by Accurate Mass Measurement. J. Am. Soc. Mass Spectrom. 17 (2006) 205-212
-
(2006)
J. Am. Soc. Mass Spectrom.
, vol.17
, pp. 205-212
-
-
Wong, R.L.1
Amster, I.J.2
-
40
-
-
0001417489
-
Correction of Time-of-Flight Shifted Polymeric Molecular Weight Distributions in Matrix-Assisted Laser Desorption/Ionization Fourier Transform Mass Spectrometry
-
O'Connor P.B., Duursma M.C., van Rooij G.J., Heeren R.M.A., and Boon J.J. Correction of Time-of-Flight Shifted Polymeric Molecular Weight Distributions in Matrix-Assisted Laser Desorption/Ionization Fourier Transform Mass Spectrometry. Anal. Chem. 69 (1997) 2751-2755
-
(1997)
Anal. Chem.
, vol.69
, pp. 2751-2755
-
-
O'Connor, P.B.1
Duursma, M.C.2
van Rooij, G.J.3
Heeren, R.M.A.4
Boon, J.J.5
-
41
-
-
0000477728
-
Determination of Molecular Weight Distributions of Polymers by MALDI-FTMS
-
Dey M., Castoro J.A., and Wilkins C.L. Determination of Molecular Weight Distributions of Polymers by MALDI-FTMS. Anal. Chem. 67 (1995) 1575-1579
-
(1995)
Anal. Chem.
, vol.67
, pp. 1575-1579
-
-
Dey, M.1
Castoro, J.A.2
Wilkins, C.L.3
-
42
-
-
0037236997
-
Initial Implementation of External Accumulation Liquid Chromatography/Electrospray Ionization Fourier Transform Ion Cyclotron Resonance with Automated Gain Control
-
Belov M.E., Rakov V.S., Nikolaev E.N., Goshe M.B., Anderson G.A., and Smith R.D. Initial Implementation of External Accumulation Liquid Chromatography/Electrospray Ionization Fourier Transform Ion Cyclotron Resonance with Automated Gain Control. Rapid Commun. Mass Spectrom. 17 (2003) 627-636
-
(2003)
Rapid Commun. Mass Spectrom.
, vol.17
, pp. 627-636
-
-
Belov, M.E.1
Rakov, V.S.2
Nikolaev, E.N.3
Goshe, M.B.4
Anderson, G.A.5
Smith, R.D.6
-
43
-
-
0035863694
-
Design and Performance of an ESI Interface for Selective External Ion Accumulation Coupled to a Fourier Transform Ion Cyclotron Mass Spectrometer
-
Belov M.E., Nikolaev E.N., Anderson G.A., Udseth H.R., Conrads T.P., Veenstra T.D., Masselon C.D., Gorshkov M.V., and Smith R.D. Design and Performance of an ESI Interface for Selective External Ion Accumulation Coupled to a Fourier Transform Ion Cyclotron Mass Spectrometer. Anal. Chem. 73 (2001) 253-261
-
(2001)
Anal. Chem.
, vol.73
, pp. 253-261
-
-
Belov, M.E.1
Nikolaev, E.N.2
Anderson, G.A.3
Udseth, H.R.4
Conrads, T.P.5
Veenstra, T.D.6
Masselon, C.D.7
Gorshkov, M.V.8
Smith, R.D.9
-
45
-
-
33646397832
-
Incorporation of a Flared Inlet Capillary Tube on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
-
Wu S., Zhang K., Kaiser N.K., Bruce J.E., Prior D.C., and Anderson G.A. Incorporation of a Flared Inlet Capillary Tube on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer. J. Am. Soc. Mass Spectrom. 17 (2006) 772-779
-
(2006)
J. Am. Soc. Mass Spectrom.
, vol.17
, pp. 772-779
-
-
Wu, S.1
Zhang, K.2
Kaiser, N.K.3
Bruce, J.E.4
Prior, D.C.5
Anderson, G.A.6
-
46
-
-
0032186198
-
An Ion Funnel Interface for Improved Ion Focusing and Sensitivity Using Electrospray Ionization Mass Spectrometry
-
Shaffer S.A., Prior D.C., Anderson G.A., Udseth H.R., and Smith R.D. An Ion Funnel Interface for Improved Ion Focusing and Sensitivity Using Electrospray Ionization Mass Spectrometry. Anal. Chem. 70 (1998) 4111-4119
-
(1998)
Anal. Chem.
, vol.70
, pp. 4111-4119
-
-
Shaffer, S.A.1
Prior, D.C.2
Anderson, G.A.3
Udseth, H.R.4
Smith, R.D.5
-
47
-
-
0032801521
-
Characterization of an Improved Electrodynamic Ion Funnel Interface for Electrospray Ionization Mass Spectrometry
-
Shaffer S.A., Tolmachev A., Prior D.C., Anderson G.A., Udseth H.R., and Smith R.D. Characterization of an Improved Electrodynamic Ion Funnel Interface for Electrospray Ionization Mass Spectrometry. Anal. Chem. 71 (1999) 2957-2964
-
(1999)
Anal. Chem.
, vol.71
, pp. 2957-2964
-
-
Shaffer, S.A.1
Tolmachev, A.2
Prior, D.C.3
Anderson, G.A.4
Udseth, H.R.5
Smith, R.D.6
-
48
-
-
46749089004
-
Restrained Ion Population Ttransfer: A Novel Ion Transfer Method for Mass Spectrometry
-
Kaiser N.K., Skulason G.E., Weisbrod C.R., Wu S., Zhang K., Prior D.C., Buschbach M.A., Anderson G.A., and Bruce J.E. Restrained Ion Population Ttransfer: A Novel Ion Transfer Method for Mass Spectrometry. Rapid Commun. Mass Spectrom. 22 (2008) 1-10
-
(2008)
Rapid Commun. Mass Spectrom.
, vol.22
, pp. 1-10
-
-
Kaiser, N.K.1
Skulason, G.E.2
Weisbrod, C.R.3
Wu, S.4
Zhang, K.5
Prior, D.C.6
Buschbach, M.A.7
Anderson, G.A.8
Bruce, J.E.9
-
49
-
-
51549091007
-
Trapping Ring Electrode Cell (TREC): A Novel FT-ICR Mass Spectrometer Cell for Improved Signal-to-Noise and Resolving Power
-
Weisbrod C.R., Kaiser N.K., Skulason G.E., and Bruce J.E. Trapping Ring Electrode Cell (TREC): A Novel FT-ICR Mass Spectrometer Cell for Improved Signal-to-Noise and Resolving Power. Anal. Chem. 80 (2008) 6545-6553
-
(2008)
Anal. Chem.
, vol.80
, pp. 6545-6553
-
-
Weisbrod, C.R.1
Kaiser, N.K.2
Skulason, G.E.3
Bruce, J.E.4
-
50
-
-
3242732359
-
Evaluation of Different Combinations of Gated Trapping, RF-Only Mode and Trap Compensation for In-Field MALDI Fourier Transform Mass Spectrometry
-
Gooden J.K., Rempel D.L., and Gross M.L. Evaluation of Different Combinations of Gated Trapping, RF-Only Mode and Trap Compensation for In-Field MALDI Fourier Transform Mass Spectrometry. J. Am. Soc. Mass Spectrom. 15 (2004) 1109-1115
-
(2004)
J. Am. Soc. Mass Spectrom.
, vol.15
, pp. 1109-1115
-
-
Gooden, J.K.1
Rempel, D.L.2
Gross, M.L.3
-
51
-
-
0001250669
-
Improvement of the Electric Field in the Cylindrical Trapped-Ion Cell
-
Naito Y., Fujiwara M., and Inoue M. Improvement of the Electric Field in the Cylindrical Trapped-Ion Cell. Int. J. Mass Spectrom. Ion Process. 120 (1992) 179-192
-
(1992)
Int. J. Mass Spectrom. Ion Process.
, vol.120
, pp. 179-192
-
-
Naito, Y.1
Fujiwara, M.2
Inoue, M.3
-
52
-
-
0030481735
-
A High-Performance Modular Data System for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
-
Senko M.W., Canterbury J.D., Guan S., and Marshall A.G. A High-Performance Modular Data System for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Rapid Commun. Mass Spectrom. 10 (1996) 1839-1844
-
(1996)
Rapid Commun. Mass Spectrom.
, vol.10
, pp. 1839-1844
-
-
Senko, M.W.1
Canterbury, J.D.2
Guan, S.3
Marshall, A.G.4
-
53
-
-
64049117448
-
-
Anderson, G. A.; Bruce, J. E.; Smith, R. D. ICR-2LS, Richland, WA, 1996.
-
Anderson, G. A.; Bruce, J. E.; Smith, R. D. ICR-2LS, Richland, WA, 1996.
-
-
-
|