메뉴 건너뛰기




Volumn 20, Issue 5, 2009, Pages 755-762

A Novel Fourier Transform Ion Cyclotron Resonance Mass Spectrometer with Improved Ion Trapping and Detection Capabilities

Author keywords

[No Author keywords available]

Indexed keywords

BIOMOLECULE ANALYSIS; CYCLOTRON MOTIONS; DC VOLTAGES; DC-BIAS VOLTAGES; DE-PHASING; DETECTION CAPABILITIES; ELECTRODYNAMIC ION FUNNELS; FOURIER TRANSFORM ION CYCLOTRON RESONANCE MASS SPECTROMETERS; FOURIER-TRANSFORM ION-CYCLOTRON RESONANCES; INDEPENDENT CONTROLS; ION ACCUMULATIONS; ION FUNNELS; ION GUIDES; ION PACKETS; ION POPULATIONS; ION TRANSFERS; ION TRANSMISSIONS; ION TRAPPING; MASS DISCRIMINATIONS; METAL CAPILLARIES; ORDER OF MAGNITUDES; OSCILLATION AMPLITUDES; QUADRUPOLE; RADIAL ELECTRIC FIELDS; RING ELECTRODES; SOURCE REGIONS; TIME OF FLIGHTS; VOLTAGE PROFILES;

EID: 64049101051     PISSN: 10440305     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jasms.2008.12.022     Document Type: Article
Times cited : (16)

References (53)
  • 1
    • 1242284991 scopus 로고    scopus 로고
    • Theoretical and Experimental Prospects for Protein Identification Based Solely on Accurate Mass Measurement
    • He F., Emmett M.R., Hakansson K., Hendrickson C.L., and Marshall A.G. Theoretical and Experimental Prospects for Protein Identification Based Solely on Accurate Mass Measurement. J. Proteome Res. 3 (2004) 61-67
    • (2004) J. Proteome Res. , vol.3 , pp. 61-67
    • He, F.1    Emmett, M.R.2    Hakansson, K.3    Hendrickson, C.L.4    Marshall, A.G.5
  • 2
    • 0033565832 scopus 로고    scopus 로고
    • Role of Accurate Mass Measurement (±10 ppm) in Protein Identification Strategies Employing MS or MS/MS and Database Searching
    • Clauser K.R., Baker P., and Burlingame A.L. Role of Accurate Mass Measurement (±10 ppm) in Protein Identification Strategies Employing MS or MS/MS and Database Searching. Anal. Chem. 71 (1999) 2871-2882
    • (1999) Anal. Chem. , vol.71 , pp. 2871-2882
    • Clauser, K.R.1    Baker, P.2    Burlingame, A.L.3
  • 3
    • 0001268221 scopus 로고
    • Fourier Transform Ion Cyclotron Resonance Spectroscopy
    • Comisarow M.B., and Marshall A.G. Fourier Transform Ion Cyclotron Resonance Spectroscopy. Chem. Phys. Lett. 25 (1974) 282-283
    • (1974) Chem. Phys. Lett. , vol.25 , pp. 282-283
    • Comisarow, M.B.1    Marshall, A.G.2
  • 4
    • 49549153202 scopus 로고
    • Frequency-Sweep Fourier Transform Ion Cyclotron Resonance Spectroscopy
    • Comisarow M.B., and Marshall A.G. Frequency-Sweep Fourier Transform Ion Cyclotron Resonance Spectroscopy. Chem. Phys. Lett. 26 (1974) 489-490
    • (1974) Chem. Phys. Lett. , vol.26 , pp. 489-490
    • Comisarow, M.B.1    Marshall, A.G.2
  • 5
    • 0030461690 scopus 로고    scopus 로고
    • Fourier Transform Mass Spectrometry
    • Amster I.J. Fourier Transform Mass Spectrometry. J. Mass Spectrom. 31 (1996) 1325-1337
    • (1996) J. Mass Spectrom. , vol.31 , pp. 1325-1337
    • Amster, I.J.1
  • 6
    • 0035253342 scopus 로고    scopus 로고
    • Baseline Mass Resolution of Peptide Isobars: A Record for Molecular Mass Resolution
    • He F., Hendrickson C.L., and Marshall A.G. Baseline Mass Resolution of Peptide Isobars: A Record for Molecular Mass Resolution. Anal. Chem. 73 (2001) 647-650
    • (2001) Anal. Chem. , vol.73 , pp. 647-650
    • He, F.1    Hendrickson, C.L.2    Marshall, A.G.3
  • 7
    • 34447338368 scopus 로고    scopus 로고
    • Parts-per-Billion Mass Measurement Accuracy Achieved through the Combination of Multiple Linear Regression and Automatic Gain Control in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
    • Williams Jr. D.K., and Muddiman D.C. Parts-per-Billion Mass Measurement Accuracy Achieved through the Combination of Multiple Linear Regression and Automatic Gain Control in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer. Anal. Chem. 79 (2007) 5058-5063
    • (2007) Anal. Chem. , vol.79 , pp. 5058-5063
    • Williams Jr., D.K.1    Muddiman, D.C.2
  • 8
    • 0032578463 scopus 로고    scopus 로고
    • Counting Individual Sulfur Atoms in a Protein by Ultrahigh-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Experimental Resolution of Isotopic Fine Structure in Proteins
    • Shi S.D.H., Hendrickson C.L., and Marshall A.G. Counting Individual Sulfur Atoms in a Protein by Ultrahigh-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Experimental Resolution of Isotopic Fine Structure in Proteins. Proc. Natl. Acad. Sci. U. S. A. 95 (1998) 11532-11537
    • (1998) Proc. Natl. Acad. Sci. U. S. A. , vol.95 , pp. 11532-11537
    • Shi, S.D.H.1    Hendrickson, C.L.2    Marshall, A.G.3
  • 10
    • 0037103713 scopus 로고    scopus 로고
    • Resolution of 11,000 Compositionally Distinct Components in a Single Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrum of Crude Oil
    • Hughey C.A., Rodgers R.P., and Marshall A.G. Resolution of 11,000 Compositionally Distinct Components in a Single Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrum of Crude Oil. Anal. Chem. 74 (2002) 4145-4149
    • (2002) Anal. Chem. , vol.74 , pp. 4145-4149
    • Hughey, C.A.1    Rodgers, R.P.2    Marshall, A.G.3
  • 11
    • 0036535032 scopus 로고    scopus 로고
    • Fourier Transform Ion Cyclotron Resonance Detection: Principles and Experimental Configurations
    • Marshall A.G., and Hendrickson C.L. Fourier Transform Ion Cyclotron Resonance Detection: Principles and Experimental Configurations. Int. J. Mass Spectrom. 215 (2002) 59-75
    • (2002) Int. J. Mass Spectrom. , vol.215 , pp. 59-75
    • Marshall, A.G.1    Hendrickson, C.L.2
  • 13
    • 33847802723 scopus 로고
    • Proposed Method for Mass Spectrometric Analysis for Ultra-Low Vapor Pressure Compounds
    • McIver Jr. R.T., Ledford Jr. E.B., and Miller J.S. Proposed Method for Mass Spectrometric Analysis for Ultra-Low Vapor Pressure Compounds. Anal. Chem. 47 (1975) 692-697
    • (1975) Anal. Chem. , vol.47 , pp. 692-697
    • McIver Jr., R.T.1    Ledford Jr., E.B.2    Miller, J.S.3
  • 14
    • 0033392170 scopus 로고    scopus 로고
    • Realistic Simulation of the Ion Cyclotron Resonance Mass Spectrometer Using a Distributed Three-Dimensional Particle-in-Cell Code
    • Mitchell D.W. Realistic Simulation of the Ion Cyclotron Resonance Mass Spectrometer Using a Distributed Three-Dimensional Particle-in-Cell Code. J. Am. Soc. Mass Spectromy. 10 (1999) 136-152
    • (1999) J. Am. Soc. Mass Spectromy. , vol.10 , pp. 136-152
    • Mitchell, D.W.1
  • 15
    • 0029679968 scopus 로고    scopus 로고
    • Prediction of a Space Charge Induced Upper Molecular Mass Limit Towards Achieving Unit Mass Resolution in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Mitchell D.W., and Smith R.D. Prediction of a Space Charge Induced Upper Molecular Mass Limit Towards Achieving Unit Mass Resolution in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Mass Spectrom. 31 (1996) 771-790
    • (1996) J. Mass Spectrom. , vol.31 , pp. 771-790
    • Mitchell, D.W.1    Smith, R.D.2
  • 16
    • 0030468505 scopus 로고    scopus 로고
    • Advantages of High Magnetic Field for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Marshall A.G., and Guan S. Advantages of High Magnetic Field for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Rapid Commun. Mass Spectrom. 10 (1996) 1819-1823
    • (1996) Rapid Commun. Mass Spectrom. , vol.10 , pp. 1819-1823
    • Marshall, A.G.1    Guan, S.2
  • 17
    • 44949150382 scopus 로고    scopus 로고
    • High-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla
    • Schaub T.M., Hendrickson C.L., Horning S., Quinn J.P., Senko M.W., and Marshall A.G. High-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla. Anal. Chem. 80 (2008) 3985-3990
    • (2008) Anal. Chem. , vol.80 , pp. 3985-3990
    • Schaub, T.M.1    Hendrickson, C.L.2    Horning, S.3    Quinn, J.P.4    Senko, M.W.5    Marshall, A.G.6
  • 18
    • 0001365594 scopus 로고
    • Cyclotron Motion of Two Coulombically Interacting Ion Clouds with Implications to Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry
    • Mitchell D.W., and Smith R.D. Cyclotron Motion of Two Coulombically Interacting Ion Clouds with Implications to Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry. Phys. Rev. E Stat. Phys Plasmas Fluids Relat. Interdisc. Topics 52 (1995) 4366-4386
    • (1995) Phys. Rev. E Stat. Phys Plasmas Fluids Relat. Interdisc. Topics , vol.52 , pp. 4366-4386
    • Mitchell, D.W.1    Smith, R.D.2
  • 19
    • 14744304574 scopus 로고    scopus 로고
    • Proteomics by FTICR Mass Spectrometry: Top Down and Bottom Up
    • Bogdanov B., and Smith R.D. Proteomics by FTICR Mass Spectrometry: Top Down and Bottom Up. Mass Spectrom. Rev. 24 (2005) 168-200
    • (2005) Mass Spectrom. Rev. , vol.24 , pp. 168-200
    • Bogdanov, B.1    Smith, R.D.2
  • 21
    • 0037133237 scopus 로고    scopus 로고
    • Top-Down Mass Spectrometry of a 29-kDa Protein for Characterization of Any Posttranslational Modification to within One Residue
    • Sze S.K., Ge Y., Oh H., and McLafferty F.W. Top-Down Mass Spectrometry of a 29-kDa Protein for Characterization of Any Posttranslational Modification to within One Residue. Proc. Natl. Acad. Sci. U. S. A. 99 (2002) 1774-1779
    • (2002) Proc. Natl. Acad. Sci. U. S. A. , vol.99 , pp. 1774-1779
    • Sze, S.K.1    Ge, Y.2    Oh, H.3    McLafferty, F.W.4
  • 22
    • 58149209966 scopus 로고
    • Ion Traps for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Principles and Design of Geometric and Electric Configurations
    • Guan S., and Marshall A.G. Ion Traps for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Principles and Design of Geometric and Electric Configurations. Int. J. Mass Spectrom. Ion Process. 146/147 (1995) 261-296
    • (1995) Int. J. Mass Spectrom. Ion Process. , vol.146-147 , pp. 261-296
    • Guan, S.1    Marshall, A.G.2
  • 23
    • 0028244357 scopus 로고
    • Evolution of Trapped Ion Cells in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Anderson J.S., Vartanian H., and Laude D.A. Evolution of Trapped Ion Cells in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Trends Anal. Chem. 13 (1994) 234-239
    • (1994) Trends Anal. Chem. , vol.13 , pp. 234-239
    • Anderson, J.S.1    Vartanian, H.2    Laude, D.A.3
  • 24
    • 0002897391 scopus 로고
    • Advances in Trapped Ion Cells for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Vartanian V.H., Anderson J.S., and Laude D.A. Advances in Trapped Ion Cells for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Mass Spectrom. Rev. 14 (1995) 1-19
    • (1995) Mass Spectrom. Rev. , vol.14 , pp. 1-19
    • Vartanian, V.H.1    Anderson, J.S.2    Laude, D.A.3
  • 25
    • 84989132905 scopus 로고
    • The Infinity Cell: A New Trapped-Ion Cell with Radiofrequency Covered Trapping Electrodes for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Caravatti P., and Allemann M. The Infinity Cell: A New Trapped-Ion Cell with Radiofrequency Covered Trapping Electrodes for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Org. Mass Spectrom. 26 (1991) 514-518
    • (1991) Org. Mass Spectrom. , vol.26 , pp. 514-518
    • Caravatti, P.1    Allemann, M.2
  • 26
    • 0001321964 scopus 로고
    • Elimination of Axial Ejection during Excitation with a Capacitively Coupled Open Trapped-Ion Cell for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Beu S.C., and Laude Jr. D.A. Elimination of Axial Ejection during Excitation with a Capacitively Coupled Open Trapped-Ion Cell for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Anal. Chem. 64 (1992) 177-180
    • (1992) Anal. Chem. , vol.64 , pp. 177-180
    • Beu, S.C.1    Laude Jr., D.A.2
  • 27
    • 0031239787 scopus 로고    scopus 로고
    • External Accumulation of Ions for Enhanced Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Senko M.W., Hendrickson C.L., Emmett M.R., Shi S.D.H., and Marshall A.G. External Accumulation of Ions for Enhanced Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Am. Soc. Mass Spectrom. 8 (1997) 970-976
    • (1997) J. Am. Soc. Mass Spectrom. , vol.8 , pp. 970-976
    • Senko, M.W.1    Hendrickson, C.L.2    Emmett, M.R.3    Shi, S.D.H.4    Marshall, A.G.5
  • 29
    • 64049113659 scopus 로고
    • U.S. Patent 4 924 089
    • Caravatti, P. U.S. Patent 4 924 089, 1990.
    • (1990)
    • Caravatti, P.1
  • 31
    • 0001106904 scopus 로고    scopus 로고
    • Minimizing Peak Coalescence: High-Resolution Separation of Isotope Peaks in Partially Deamidated Peptides by Matrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Stults J.T. Minimizing Peak Coalescence: High-Resolution Separation of Isotope Peaks in Partially Deamidated Peptides by Matrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Anal. Chem. 69 (1997) 1815-1819
    • (1997) Anal. Chem. , vol.69 , pp. 1815-1819
    • Stults, J.T.1
  • 32
    • 0031569138 scopus 로고    scopus 로고
    • Detection, Number, and Sequence Location of Sulfur-Containing Amino Acids and Disulfide Bridges in Peptides by Ultrahigh-Resolution MALDI FTICR Mass Spectrometry
    • Solouki T., Emmett M.R., Guan S., and Marshall A.G. Detection, Number, and Sequence Location of Sulfur-Containing Amino Acids and Disulfide Bridges in Peptides by Ultrahigh-Resolution MALDI FTICR Mass Spectrometry. Anal. Chem. 69 (1997) 1163-1168
    • (1997) Anal. Chem. , vol.69 , pp. 1163-1168
    • Solouki, T.1    Emmett, M.R.2    Guan, S.3    Marshall, A.G.4
  • 33
    • 0001200142 scopus 로고
    • Evolution of an Ion Cloud in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer during Signal Detection: Its Influence on Spectral Line Shape and Position
    • Nikolaev E.N., Miluchihin N., and Inoue M. Evolution of an Ion Cloud in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer during Signal Detection: Its Influence on Spectral Line Shape and Position. Int. J. Mass Spectrom. Ion Process. 148 (1995) 145-157
    • (1995) Int. J. Mass Spectrom. Ion Process. , vol.148 , pp. 145-157
    • Nikolaev, E.N.1    Miluchihin, N.2    Inoue, M.3
  • 34
    • 33751004176 scopus 로고    scopus 로고
    • Sub Part-per-Million Mass Accuracy by Using Stepwise-External Calibration in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Wong R.L., and Amster I.J. Sub Part-per-Million Mass Accuracy by Using Stepwise-External Calibration in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Am. Soc. Mass Spectrom. 17 (2006) 1681-1691
    • (2006) J. Am. Soc. Mass Spectrom. , vol.17 , pp. 1681-1691
    • Wong, R.L.1    Amster, I.J.2
  • 35
    • 0001246359 scopus 로고
    • High-Resolution Accurate Mass Measurements of Biomolecules Using a New Electrospray Ionization Ion Cyclotron Resonance Mass Spectrometer
    • Winger B.E., Hofstadler S.A., Bruce J.E., Udseth H.R., and Smith R.D. High-Resolution Accurate Mass Measurements of Biomolecules Using a New Electrospray Ionization Ion Cyclotron Resonance Mass Spectrometer. J. Am. Soc. Mass Spectrom. 4 (1993) 566-577
    • (1993) J. Am. Soc. Mass Spectrom. , vol.4 , pp. 566-577
    • Winger, B.E.1    Hofstadler, S.A.2    Bruce, J.E.3    Udseth, H.R.4    Smith, R.D.5
  • 36
    • 0000173772 scopus 로고
    • Shrink-Wrapping an Ion Cloud for High-Performance Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Guan S., Kim H.S., Marshall A.G., Wahl M.C., Wood T.D., and Xiang X. Shrink-Wrapping an Ion Cloud for High-Performance Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Chem. Rev. 94 (1994) 2161-2182
    • (1994) Chem. Rev. , vol.94 , pp. 2161-2182
    • Guan, S.1    Kim, H.S.2    Marshall, A.G.3    Wahl, M.C.4    Wood, T.D.5    Xiang, X.6
  • 37
    • 0000332198 scopus 로고
    • Circularly Polarized Quadrature Excitation for Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry
    • Guan S., Gorshkov M.V., and Marshall A.G. Circularly Polarized Quadrature Excitation for Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry. Chem. Phys. Lett. 198 (1992) 143-148
    • (1992) Chem. Phys. Lett. , vol.198 , pp. 143-148
    • Guan, S.1    Gorshkov, M.V.2    Marshall, A.G.3
  • 38
    • 0038824578 scopus 로고    scopus 로고
    • Improved Ion Extraction from a Linear Octopole Ion Trap: SIMION Analysis and Experimental Demonstration
    • Wilcox B.E., Hendrickson C.L., and Marshall A.G. Improved Ion Extraction from a Linear Octopole Ion Trap: SIMION Analysis and Experimental Demonstration. J. Am. Soc. Mass Spectrom. 13 (2002) 1304-1312
    • (2002) J. Am. Soc. Mass Spectrom. , vol.13 , pp. 1304-1312
    • Wilcox, B.E.1    Hendrickson, C.L.2    Marshall, A.G.3
  • 39
    • 31844448971 scopus 로고    scopus 로고
    • Combining Low and High Mass Ion Accumulation for Enhancing Shotgun Proteome Analysis by Accurate Mass Measurement
    • Wong R.L., and Amster I.J. Combining Low and High Mass Ion Accumulation for Enhancing Shotgun Proteome Analysis by Accurate Mass Measurement. J. Am. Soc. Mass Spectrom. 17 (2006) 205-212
    • (2006) J. Am. Soc. Mass Spectrom. , vol.17 , pp. 205-212
    • Wong, R.L.1    Amster, I.J.2
  • 40
    • 0001417489 scopus 로고    scopus 로고
    • Correction of Time-of-Flight Shifted Polymeric Molecular Weight Distributions in Matrix-Assisted Laser Desorption/Ionization Fourier Transform Mass Spectrometry
    • O'Connor P.B., Duursma M.C., van Rooij G.J., Heeren R.M.A., and Boon J.J. Correction of Time-of-Flight Shifted Polymeric Molecular Weight Distributions in Matrix-Assisted Laser Desorption/Ionization Fourier Transform Mass Spectrometry. Anal. Chem. 69 (1997) 2751-2755
    • (1997) Anal. Chem. , vol.69 , pp. 2751-2755
    • O'Connor, P.B.1    Duursma, M.C.2    van Rooij, G.J.3    Heeren, R.M.A.4    Boon, J.J.5
  • 41
    • 0000477728 scopus 로고
    • Determination of Molecular Weight Distributions of Polymers by MALDI-FTMS
    • Dey M., Castoro J.A., and Wilkins C.L. Determination of Molecular Weight Distributions of Polymers by MALDI-FTMS. Anal. Chem. 67 (1995) 1575-1579
    • (1995) Anal. Chem. , vol.67 , pp. 1575-1579
    • Dey, M.1    Castoro, J.A.2    Wilkins, C.L.3
  • 42
    • 0037236997 scopus 로고    scopus 로고
    • Initial Implementation of External Accumulation Liquid Chromatography/Electrospray Ionization Fourier Transform Ion Cyclotron Resonance with Automated Gain Control
    • Belov M.E., Rakov V.S., Nikolaev E.N., Goshe M.B., Anderson G.A., and Smith R.D. Initial Implementation of External Accumulation Liquid Chromatography/Electrospray Ionization Fourier Transform Ion Cyclotron Resonance with Automated Gain Control. Rapid Commun. Mass Spectrom. 17 (2003) 627-636
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , pp. 627-636
    • Belov, M.E.1    Rakov, V.S.2    Nikolaev, E.N.3    Goshe, M.B.4    Anderson, G.A.5    Smith, R.D.6
  • 45
    • 33646397832 scopus 로고    scopus 로고
    • Incorporation of a Flared Inlet Capillary Tube on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
    • Wu S., Zhang K., Kaiser N.K., Bruce J.E., Prior D.C., and Anderson G.A. Incorporation of a Flared Inlet Capillary Tube on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer. J. Am. Soc. Mass Spectrom. 17 (2006) 772-779
    • (2006) J. Am. Soc. Mass Spectrom. , vol.17 , pp. 772-779
    • Wu, S.1    Zhang, K.2    Kaiser, N.K.3    Bruce, J.E.4    Prior, D.C.5    Anderson, G.A.6
  • 46
    • 0032186198 scopus 로고    scopus 로고
    • An Ion Funnel Interface for Improved Ion Focusing and Sensitivity Using Electrospray Ionization Mass Spectrometry
    • Shaffer S.A., Prior D.C., Anderson G.A., Udseth H.R., and Smith R.D. An Ion Funnel Interface for Improved Ion Focusing and Sensitivity Using Electrospray Ionization Mass Spectrometry. Anal. Chem. 70 (1998) 4111-4119
    • (1998) Anal. Chem. , vol.70 , pp. 4111-4119
    • Shaffer, S.A.1    Prior, D.C.2    Anderson, G.A.3    Udseth, H.R.4    Smith, R.D.5
  • 47
    • 0032801521 scopus 로고    scopus 로고
    • Characterization of an Improved Electrodynamic Ion Funnel Interface for Electrospray Ionization Mass Spectrometry
    • Shaffer S.A., Tolmachev A., Prior D.C., Anderson G.A., Udseth H.R., and Smith R.D. Characterization of an Improved Electrodynamic Ion Funnel Interface for Electrospray Ionization Mass Spectrometry. Anal. Chem. 71 (1999) 2957-2964
    • (1999) Anal. Chem. , vol.71 , pp. 2957-2964
    • Shaffer, S.A.1    Tolmachev, A.2    Prior, D.C.3    Anderson, G.A.4    Udseth, H.R.5    Smith, R.D.6
  • 49
    • 51549091007 scopus 로고    scopus 로고
    • Trapping Ring Electrode Cell (TREC): A Novel FT-ICR Mass Spectrometer Cell for Improved Signal-to-Noise and Resolving Power
    • Weisbrod C.R., Kaiser N.K., Skulason G.E., and Bruce J.E. Trapping Ring Electrode Cell (TREC): A Novel FT-ICR Mass Spectrometer Cell for Improved Signal-to-Noise and Resolving Power. Anal. Chem. 80 (2008) 6545-6553
    • (2008) Anal. Chem. , vol.80 , pp. 6545-6553
    • Weisbrod, C.R.1    Kaiser, N.K.2    Skulason, G.E.3    Bruce, J.E.4
  • 50
    • 3242732359 scopus 로고    scopus 로고
    • Evaluation of Different Combinations of Gated Trapping, RF-Only Mode and Trap Compensation for In-Field MALDI Fourier Transform Mass Spectrometry
    • Gooden J.K., Rempel D.L., and Gross M.L. Evaluation of Different Combinations of Gated Trapping, RF-Only Mode and Trap Compensation for In-Field MALDI Fourier Transform Mass Spectrometry. J. Am. Soc. Mass Spectrom. 15 (2004) 1109-1115
    • (2004) J. Am. Soc. Mass Spectrom. , vol.15 , pp. 1109-1115
    • Gooden, J.K.1    Rempel, D.L.2    Gross, M.L.3
  • 51
    • 0001250669 scopus 로고
    • Improvement of the Electric Field in the Cylindrical Trapped-Ion Cell
    • Naito Y., Fujiwara M., and Inoue M. Improvement of the Electric Field in the Cylindrical Trapped-Ion Cell. Int. J. Mass Spectrom. Ion Process. 120 (1992) 179-192
    • (1992) Int. J. Mass Spectrom. Ion Process. , vol.120 , pp. 179-192
    • Naito, Y.1    Fujiwara, M.2    Inoue, M.3
  • 52
    • 0030481735 scopus 로고    scopus 로고
    • A High-Performance Modular Data System for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Senko M.W., Canterbury J.D., Guan S., and Marshall A.G. A High-Performance Modular Data System for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Rapid Commun. Mass Spectrom. 10 (1996) 1839-1844
    • (1996) Rapid Commun. Mass Spectrom. , vol.10 , pp. 1839-1844
    • Senko, M.W.1    Canterbury, J.D.2    Guan, S.3    Marshall, A.G.4
  • 53
    • 64049117448 scopus 로고    scopus 로고
    • Anderson, G. A.; Bruce, J. E.; Smith, R. D. ICR-2LS, Richland, WA, 1996.
    • Anderson, G. A.; Bruce, J. E.; Smith, R. D. ICR-2LS, Richland, WA, 1996.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.