Volumn 36, Issue 4, 2009, Pages 1098-1108

CZT detectors used in different irradiation geometries: Simulations and experimental results

Author keywords

CZT detector; edge on; energy spectrum; tailing effect; tilted angle

Indexed keywords

GEOMETRY; IRRADIATION; PHOTONS; RADIATION; SPECTROSCOPY;

EID: 63849193968     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3085876     Document Type: Article
Times cited : (14)

References (28)
  • 5
    • 0021812629 scopus 로고
    • SNR and DQE Analysis of broad spectrum x-ray imaging
    • M. J. Tapiovaara and R. F. Wagner, " SNR and DQE Analysis of broad spectrum x-ray imaging.," Phys. Med. Biol. 30, 519-529 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 519-529
    • Tapiovaara, M.J.1    Wagner, R.F.2
  • 6
    • 33747603940 scopus 로고    scopus 로고
    • Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging
    • P. M. Shikhaliev, " Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.," Phys. Med. Biol. 51, 4267-4287 (2006).
    • (2006) Phys. Med. Biol. , vol.51 , pp. 4267-4287
    • Shikhaliev, P.M.1
  • 7
    • 42649114425 scopus 로고    scopus 로고
    • Computed tomography with energy resolved detection: A feasibility study
    • P. M. Shikhaliev, " Computed tomography with energy resolved detection: A feasibility study.," Phys. Med. Biol. 53, 1475-1495 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 1475-1495
    • Shikhaliev, P.M.1
  • 8
    • 0033461146 scopus 로고    scopus 로고
    • Detective quantum efficiency dependence on x-ray energy weighting in mammography
    • R. N. Cahn, " Detective quantum efficiency dependence on x-ray energy weighting in mammography.," Med. Phys. 26 (12), 2680-2683 (1999).
    • (1999) Med. Phys. , vol.26 , Issue.12 , pp. 2680-2683
    • Cahn, R.N.1
  • 9
    • 58149231346 scopus 로고    scopus 로고
    • Energy resolved computed tomography: First experimental results
    • P. M. Shikhaliev, " Energy resolved computed tomography: First experimental results.," Phys. Med. Biol. 53, 5595-5613 (2008).
    • (2008) Phys. Med. Biol. , vol.53 , pp. 5595-5613
    • Shikhaliev, P.M.1
  • 10
    • 2342516100 scopus 로고    scopus 로고
    • Compact CT/SPECT small-animal imaging system
    • G. A. Kastis, " Compact CT/SPECT small-animal imaging system.," IEEE Trans. Nucl. Sci. 51 (1), 63-67 (2004).
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.1 , pp. 63-67
    • Kastis, G.A.1
  • 11
    • 19944363491 scopus 로고    scopus 로고
    • Performance and perspectives of a CdZnTe-based gamma camera for medical imaging
    • L. Verger, " Performance and perspectives of a CdZnTe-based gamma camera for medical imaging.," IEEE Trans. Nucl. Sci. 51 (6), 3111-3117 (2004).
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.6 , pp. 3111-3117
    • Verger, L.1
  • 12
    • 0036464362 scopus 로고    scopus 로고
    • Direct conversion CdZnTe and CdTe detectors for digital mammography
    • S. Yin, " Direct conversion CdZnTe and CdTe detectors for digital mammography.," IEEE Trans. Nucl. Sci. 49 (1), 176-181 (2002).
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.1 , pp. 176-181
    • Yin, S.1
  • 15
    • 45849108387 scopus 로고    scopus 로고
    • Testing an energy-dispersive counting-mode detector with hard x-rays from a synchrotron source
    • C. Bäumer, " Testing an energy-dispersive counting-mode detector with hard x-rays from a synchrotron source.," IEEE Trans. Nucl. Sci. 55 (3), 1785-1790 (2008).
    • (2008) IEEE Trans. Nucl. Sci. , vol.55 , Issue.3 , pp. 1785-1790
    • Bäumer, C.1
  • 16
    • 4244180299 scopus 로고
    • Charge transport in arrays of semiconductor gamma-ray detectors
    • H. H. Barrett, J. D. Eskin, and H. B. Barber, " Charge transport in arrays of semiconductor gamma-ray detectors.," Phys. Rev. Lett. 75 (1), 156-159 (1995).
    • (1995) Phys. Rev. Lett. , vol.75 , Issue.1 , pp. 156-159
    • Barrett, H.H.1    Eskin, J.D.2    Barber, H.B.3
  • 17
    • 0030786835 scopus 로고    scopus 로고
    • Design and evaluation of AC-coupled, FOXFET-biased, edge-on silicon strip detectors for x-ray imaging
    • F. Arfelli, " Design and evaluation of AC-coupled, FOXFET-biased, edge-on silicon strip detectors for x-ray imaging.," Nucl. Instrum. Methods Phys. Res. A 385 (2), 311-20 (1997).
    • (1997) Nucl. Instrum. Methods Phys. Res. A , vol.385 , Issue.2 , pp. 311-320
    • Arfelli, F.1
  • 18
    • 2442650302 scopus 로고    scopus 로고
    • Scanning-slit photon counting x-ray imaging system using a microchannel plate detector
    • P. M. Shikhaliev, " Scanning-slit photon counting x-ray imaging system using a microchannel plate detector.," Med. Phys. 31 (5), 1061-1071 (2004).
    • (2004) Med. Phys. , vol.31 , Issue.5 , pp. 1061-1071
    • Shikhaliev, P.M.1
  • 19
    • 0030211723 scopus 로고    scopus 로고
    • Evaluation of CdTe for use in a prototype emission/transmission CT imaging system
    • P. R. Bennett, " Evaluation of CdTe for use in a prototype emission/transmission CT imaging system.," IEEE Trans. Nucl. Sci. 43 (4), 2225-2229 (1996).
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.4 , pp. 2225-2229
    • Bennett, P.R.1
  • 20
    • 13644261252 scopus 로고    scopus 로고
    • High-resolution PET detector design: Modelling components of intrinsic spatial resolution
    • J. R. Stickel and S. R. Cherry, " High-resolution PET detector design: Modelling components of intrinsic spatial resolution.," Phys. Med. Biol. 50, 179-195 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 179-195
    • Stickel, J.R.1    Cherry, S.R.2
  • 21
    • 0035339180 scopus 로고    scopus 로고
    • Response calculation of a stacked CdZnTe detector for N-16 gamma-ray measurement
    • H. Nishizawa, " Response calculation of a stacked CdZnTe detector for N-16 gamma-ray measurement.," Nucl. Instrum. Methods Phys. Res. A 463, 268-274 (2001).
    • (2001) Nucl. Instrum. Methods Phys. Res. A , vol.463 , pp. 268-274
    • Nishizawa, H.1
  • 22
    • 0010778173 scopus 로고
    • Zum Mechanismus des lichtelektrischen primarstromes in isolierenden kristallen
    • K. Hecht, " Zum Mechanismus des lichtelektrischen primarstromes in isolierenden kristallen.," Z. Phys. 77, 235-245 (1932).
    • (1932) Z. Phys. , vol.77 , pp. 235-245
    • Hecht, K.1
  • 23
    • 0001562039 scopus 로고
    • Gamma response of semi-insulating material in the presence of trapping and detrapping
    • W. Akutagawa and K. Zańio, " Gamma response of semi-insulating material in the presence of trapping and detrapping.," J. Appl. Phys. 40 (9), 3838-3854 (1969).
    • (1969) J. Appl. Phys. , vol.40 , Issue.9 , pp. 3838-3854
    • Akutagawa, W.1    Zańio, K.2
  • 24
    • 0000611238 scopus 로고    scopus 로고
    • Signals induced in semiconductor gamma-ray imaging detectors
    • J. D. Eskin, H. H. Barrett, and H. B. Barber, " Signals induced in semiconductor gamma-ray imaging detectors.," J. Appl. Phys. 85 (2), 647-659 (1999).
    • (1999) J. Appl. Phys. , vol.85 , Issue.2 , pp. 647-659
    • Eskin, J.D.1    Barrett, H.H.2    Barber, H.B.3
  • 25
    • 34548138875 scopus 로고    scopus 로고
    • Crystal growth and characterization of detector grade (Cd,Zn)Te crystals
    • M. Fiederle, A. Fauler, and A. Zwerger, " Crystal growth and characterization of detector grade (Cd,Zn)Te crystals.," IEEE Trans. Nucl. Sci. 54 (4), 769-772 (2007).
    • (2007) IEEE Trans. Nucl. Sci. , vol.54 , Issue.4 , pp. 769-772
    • Fiederle, M.1    Fauler, A.2    Zwerger, A.3
  • 26
    • 0001157513 scopus 로고
    • Charge-carrier mobilities in CdZnTe single crystals used as nuclear radiation detectors
    • Z. Burshtein, " Charge-carrier mobilities in CdZnTe single crystals used as nuclear radiation detectors.," Appl. Phys. Lett. 63 (1), 102-104 (1993).
    • (1993) Appl. Phys. Lett. , vol.63 , Issue.1 , pp. 102-104
    • Burshtein, Z.1
  • 27
    • 3042641613 scopus 로고    scopus 로고
    • Scatter rejection in scanned multi-slit digital mammography
    • M. Aslund, " Scatter rejection in scanned multi-slit digital mammography.," Proc. SPIE 5368, 478-487 (2004).
    • (2004) Proc. SPIE , vol.5368 , pp. 478-487
    • Aslund, M.1
  • 28
    • 0030172710 scopus 로고    scopus 로고
    • Signal generation in CdZnTe strip detectors
    • L. A. Hamel, " Signal generation in CdZnTe strip detectors.," IEEE Trans. Nucl. Sci. 43 (3), 1422-1426 (1996).
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.3 , pp. 1422-1426
    • Hamel, L.A.1