메뉴 건너뛰기




Volumn 54, Issue 3, 2009, Pages 665-677

Computerized method for estimation of the location of a lung tumor on EPID cine images without implanted markers in stereotactic body radiotherapy

Author keywords

[No Author keywords available]

Indexed keywords

CINE IMAGES; COMPUTERIZED METHODS; CROSS-CORRELATION VALUES; ELECTRONIC PORTAL IMAGING DEVICES; GRAY LEVELS; LOCATION ERRORS; LUNG TUMORS; MANUAL METHODS; NON-SMALL-CELL LUNG CANCERS; PIXEL SIZES; REGION-GROWING TECHNIQUES; SAMPLING RATES; STEREOTACTIC BODY RADIOTHERAPIES; TEMPLATE IMAGES; TEMPLATE MATCHING TECHNIQUES; THRESHOLDING TECHNIQUES;

EID: 63649162853     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/3/013     Document Type: Article
Times cited : (37)

References (19)
  • 2
    • 0035996453 scopus 로고    scopus 로고
    • Development of a computerized method for identifying the posteroanterior and lateral views of chest radiographs by use of a template matching technique
    • Arimura H, Katsuragawa S, Li Q, Ishida T and Doi K 2002 Development of a computerized method for identifying the posteroanterior and lateral views of chest radiographs by use of a template matching technique Med. Phys. 29 1556-61
    • (2002) Med. Phys. , vol.29 , Issue.7 , pp. 1556-1561
    • Arimura, H.1    Katsuragawa, S.2    Li, Q.3    Ishida, T.4    Doi, K.5
  • 3
    • 2542474244 scopus 로고    scopus 로고
    • Computerized scheme for automated detection of lung nodules in low-dose CT images for lung cancer screening
    • Arimura H, Katsuragawa S, Suzuki K, Li F, Shiraishi J and Doi K 2004 Computerized scheme for automated detection of lung nodules in low-dose CT images for lung cancer screening Acad. Radiol. 11 617-29
    • (2004) Acad. Radiol. , vol.11 , Issue.6 , pp. 617-629
    • Arimura, H.1    Katsuragawa, S.2    Suzuki, K.3    Li, F.4    Shiraishi, J.5    Doi, K.6
  • 4
    • 34547850184 scopus 로고    scopus 로고
    • Clinical feasibility of using an EPID cine mode for image-guided verification of stereotactic body radiotherapy
    • Berbeco R I, Hacker F, Ionascu D and Mamon H J 2007 Clinical feasibility of using an EPID cine mode for image-guided verification of stereotactic body radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 69 258-66
    • (2007) Int. J. Radiat. Oncol. Biol. Phys. , vol.69 , Issue.1 , pp. 258-266
    • Berbeco, R.I.1    Hacker, F.2    Ionascu, D.3    Mamon, H.J.4
  • 5
    • 0037237809 scopus 로고    scopus 로고
    • Respiration-correlated spiral CT: A method of measuring respiratory induced anatomic motion for radiation treatment planning
    • Ford E C, Mageras G S, Yorke E and Ling C C 2003 Respiration-correlated spiral CT: a method of measuring respiratory induced anatomic motion for radiation treatment planning Med. Phys. 30 88-97
    • (2003) Med. Phys. , vol.30 , Issue.1 , pp. 88-97
    • Ford, E.C.1    Mageras, G.S.2    Yorke, E.3    Ling, C.C.4
  • 6
    • 55649085011 scopus 로고    scopus 로고
    • International Commission on Radiation Units and Measurements (ICRU)
    • International Commission on Radiation Units and Measurements (ICRU) 1999 Prescribing, Recording and Reporting Photon Beam Therapy (Supplement to ICRU Report 50) Report 62 (Bethesda: ICRU)
    • (1999) Report 62
  • 7
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • Keall P J et al 2006 The management of respiratory motion in radiation oncology report of AAPM Task Group 76 Med. Phys. 33 3874-900
    • (2006) Med. Phys. , vol.33 , Issue.10 , pp. 3874-3900
    • Keall, P.J.1    Al, E.2
  • 9
    • 33646454283 scopus 로고    scopus 로고
    • Tracking moving objects with megavoltage portal imaging: A feasibility study
    • Meyer J, Richter A, Baier K, Wilbert J, Guckenberger M and Flentje M 2006 Tracking moving objects with megavoltage portal imaging: a feasibility study Med. Phys. 33 1275-80
    • (2006) Med. Phys. , vol.33 , Issue.5 , pp. 1275-1280
    • Meyer, J.1    Richter, A.2    Baier, K.3    Wilbert, J.4    Guckenberger, M.5    Flentje, M.6
  • 11
    • 37549062637 scopus 로고    scopus 로고
    • Dosimetric impact of motion in free-breathing and gated lung radiotherapy: A 4D Monte Carlo study of intrafraction and interfraction effects
    • Seco J, Sharp G C, Wu Z, Gierga D, Buettner F and Paganetti H 2008 Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects Med. Phys. 35 356-66
    • (2008) Med. Phys. , vol.35 , Issue.1 , pp. 356-366
    • Seco, J.1    Sharp, G.C.2    Wu, Z.3    Gierga, D.4    Buettner, F.5    Paganetti, H.6
  • 12
    • 34347405112 scopus 로고    scopus 로고
    • Automatic segmentation of phase-correlated CT scans through nonrigid image registration using geometrically regularized free-form deformation
    • Shekhar R, Lei P, Castro-Pareja C R, Plishker W L and D'Souza W D 2007 Automatic segmentation of phase-correlated CT scans through nonrigid image registration using geometrically regularized free-form deformation Med. Phys. 34 3054-66
    • (2007) Med. Phys. , vol.34 , Issue.7 , pp. 3054-3066
    • Shekhar, R.1    Lei, P.2    Castro-Pareja, C.R.3    Plishker, W.L.4    D'Souza, W.D.5
  • 14
    • 0033824313 scopus 로고    scopus 로고
    • Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    • Shirato H et al 2000a Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor Int. J. Radiat. Oncol. Biol. Phys. 48 435-42
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.48 , Issue.4 , pp. 1187-442
    • Shirato, H.1    Al, E.2
  • 15
    • 0034333029 scopus 로고    scopus 로고
    • Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    • Shirato H et al 2000b Physical aspects of a real-time tumor-tracking system for gated radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 48 1187-95
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.48 , Issue.4 , pp. 1187-1195
    • Shirato, H.1    Al, E.2
  • 16
    • 33748879202 scopus 로고    scopus 로고
    • 4D imaging for target definition in stereotactic radiotherapy for lung cancer
    • Slotman B J, Lagerwaard F J and Senan S 2006 4D imaging for target definition in stereotactic radiotherapy for lung cancer Acta Oncol 45 966-72
    • (2006) Acta Oncol , vol.45 , Issue.7 , pp. 966-972
    • Slotman, B.J.1    Lagerwaard, F.J.2    Senan, S.3
  • 17
    • 1942452264 scopus 로고    scopus 로고
    • Aperture maneuver with compelled breath (AMC) for moving tumors: A feasibility study with a moving phantom
    • Suh Y, Yi B, Ahn S, Kim J, Lee S, Shin S, Shin S and Choi E 2004 Aperture maneuver with compelled breath (AMC) for moving tumors: a feasibility study with a moving phantom Med. Phys. 31 760-6
    • (2004) Med. Phys. , vol.31 , Issue.4 , pp. 760-766
    • Suh, Y.1    Yi, B.2    Ahn, S.3    Kim, J.4    Lee, S.5    Shin, S.6    Shin, S.7    Choi, E.8
  • 18
    • 34547275812 scopus 로고    scopus 로고
    • Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking
    • Tang X, Sharp G C and Jiang S B 2007 Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking Phys. Med. Biol. 52 4081-98
    • (2007) Phys. Med. Biol. , vol.52 , Issue.14 , pp. 4081-4098
    • Tang, X.1    Sharp, G.C.2    Jiang, S.B.3
  • 19
    • 21144445222 scopus 로고    scopus 로고
    • Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery
    • Vedam S, Docef A, Fix M, Murphy M and Keall P J 2005 Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery Med. Phys. 32 1607-20
    • (2005) Med. Phys. , vol.32 , Issue.6 , pp. 1607-1620
    • Vedam, S.1    Docef, A.2    Fix, M.3    Murphy, M.4    Keall, P.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.