Volumn 70, Issue 1, 1999, Pages 25-28

Impaction bone-grafting increases the holding power of cancellous screws in the femoral head. A pull-out study in human cadaver hips

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BONE GRAFT; BONE MATRIX; BONE MINERAL; BONE SCREW; CADAVER; CANCELLOUS BONE; CONTROLLED STUDY; FEMUR HEAD; FORCE; HUMAN; NORMAL HUMAN; STRENGTH;

EID: 0033031128     PISSN: 00016470     EISSN: None     Source Type: Journal    
DOI: 10.3109/17453679909000952     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 0026527438 scopus 로고
    • Implant holding power of the femoral head. A cadaver study of fracture screws
    • Benterud J G, Husby T, Graadahl O, Alho A. Implant holding power of the femoral head. A cadaver study of fracture screws. Acta Orthop Scand 1992; 63 (1): 47-9.
    • (1992) Acta Orthop Scand , vol.63 , Issue.1 , pp. 47-49
    • Benterud, J.G.1    Husby, T.2    Graadahl, O.3    Alho, A.4
  • 2
    • 0025168376 scopus 로고
    • Femoral neck fracture fixation. Comparison of a sliding screw with lag screws
    • Clark D I, Crofts C E, Saleh M. Femoral neck fracture fixation. Comparison of a sliding screw with lag screws. J Bone Joint Surg (Br) 1990; 72 (5): 797-800.
    • (1990) J Bone Joint Surg (Br) , vol.72 , Issue.5 , pp. 797-800
    • Clark, D.I.1    Crofts, C.E.2    Saleh, M.3
  • 3
    • 0019773810 scopus 로고
    • Treatment of displaced fractures of the femoral neck
    • Frandsen P A, Andersen P E Jr. Treatment of displaced fractures of the femoral neck. Acta Orthop Scand 1981; 52: 547-52.
    • (1981) Acta Orthop Scand , vol.52 , pp. 547-552
    • Frandsen, P.A.1    Andersen P.E., Jr.2
  • 5
    • 0020056252 scopus 로고
    • Dislocated femoral neck fractures. A follow-up study of 98 cases treated by (ASIF) cancellous bone screws
    • Hogh J, Jensen J, Lauritzen J. Dislocated femoral neck fractures. A follow-up study of 98 cases treated by (ASIF) cancellous bone screws. Acta Orthop Scand 1982; 53: 245-9.
    • (1982) Acta Orthop Scand , vol.53 , pp. 245-249
    • Hogh, J.1    Jensen, J.2    Lauritzen, J.3
  • 6
    • 0026440671 scopus 로고
    • Holding power and reinforcement of cancellous screws in human bone
    • Kleeman B C, Takeuchi T, Gerhart T N, Hayes W C. Holding power and reinforcement of cancellous screws in human bone. Clin Orthop 1992; 284: 260-6.
    • (1992) Clin Orthop , vol.284 , pp. 260-266
    • Kleeman, B.C.1    Takeuchi, T.2    Gerhart, T.N.3    Hayes, W.C.4
  • 7
    • 0027101880 scopus 로고
    • Holding power of metallic screws in cancellous bone and metallic plates in cortical bone. An experimental study on rabbits using polymethylmethacrylate and bone graft as supporting material
    • Lapinsuo M, Patiala H, Sammaljarvi E, Majola A, Taurio R, Tormala P, Rokkanen P. Holding power of metallic screws in cancellous bone and metallic plates in cortical bone. An experimental study on rabbits using polymethylmethacrylate and bone graft as supporting material. Ann Chir Gynaecol 1992; 81 (4): 378-82.
    • (1992) Ann Chir Gynaecol , vol.81 , Issue.4 , pp. 378-382
    • Lapinsuo, M.1    Patiala, H.2    Sammaljarvi, E.3    Majola, A.4    Taurio, R.5    Tormala, P.6    Rokkanen, P.7
  • 9
    • 0013573991 scopus 로고
    • Oberflächliche knochenresorption um implantate
    • Perren S M, Ganz R, Rüter A. Oberflächliche knochenresorption um implantate. Med Orthop Tech 1975; 95 (6): 243-6.
    • (1975) Med Orthop Tech , vol.95 , Issue.6 , pp. 243-246
    • Perren, S.M.1    Ganz, R.2    Rüter, A.3
  • 10
    • 0016707373 scopus 로고
    • The effect of movement on the holding power of screws in bone
    • Schatzker J, Horne J, Sumner-Smith G. The effect of movement on the holding power of screws in bone. Clin Orthop 1975; 111: 257-62.
    • (1975) Clin Orthop , vol.111 , pp. 257-262
    • Schatzker, J.1    Horne, J.2    Sumner-Smith, G.3
  • 11
    • 0022639974 scopus 로고
    • Compression screw fixation for displaced femoral neck fractures: Success or failure?
    • Skinner P W, Powles D. Compression screw fixation for displaced femoral neck fractures: Success or failure? J Bone Joint Surg (Br) 1986; 86 (1): 78-82.
    • (1986) J Bone Joint Surg (Br) , vol.86 , Issue.1 , pp. 78-82
    • Skinner, P.W.1    Powles, D.2
  • 12
    • 0027930867 scopus 로고
    • Current concepts review. Intracapsular fractures of the hip
    • Swiontkowski M F. Current concepts review. Intracapsular fractures of the hip. J Bone Joint Surg (Am) 1994;76 (1): 129-38.
    • (1994) J Bone Joint Surg (Am) , vol.76 , Issue.1 , pp. 129-138
    • Swiontkowski, M.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.