-
1
-
-
0141499867
-
Bone strength and its determinants
-
Ammann P., and Rizzoli R. Bone strength and its determinants. Osteoporos. Int. 14 Suppl 3 (2003) S13-18
-
(2003)
Osteoporos. Int.
, vol.14
, Issue.SUPPL. 3
-
-
Ammann, P.1
Rizzoli, R.2
-
2
-
-
0028963682
-
Risk factors for hip fracture in white women. Study of Osteoporotic Fractures Research Group
-
Cummings S.R., Nevitt M.C., Browner W.S., et al. Risk factors for hip fracture in white women. Study of Osteoporotic Fractures Research Group. N. Engl. J. Med. 332 (1995) 767-773
-
(1995)
N. Engl. J. Med.
, vol.332
, pp. 767-773
-
-
Cummings, S.R.1
Nevitt, M.C.2
Browner, W.S.3
-
4
-
-
4444366809
-
Long-term prediction of incident hip fracture risk in elderly white women: study of osteoporotic fractures
-
Taylor B.C., Schreiner P.J., Stone K.L., et al. Long-term prediction of incident hip fracture risk in elderly white women: study of osteoporotic fractures. J. Am. Geriatr. Soc. 52 (2004) 1479-1486
-
(2004)
J. Am. Geriatr. Soc.
, vol.52
, pp. 1479-1486
-
-
Taylor, B.C.1
Schreiner, P.J.2
Stone, K.L.3
-
5
-
-
25444529444
-
Multi-detector row CT imaging of vertebral microstructure for evaluation of fracture risk
-
Ito M., Ikeda K., Nishiguchi M., et al. Multi-detector row CT imaging of vertebral microstructure for evaluation of fracture risk. J. Bone Miner. Res. 20 (2005) 1828-1836
-
(2005)
J. Bone Miner. Res.
, vol.20
, pp. 1828-1836
-
-
Ito, M.1
Ikeda, K.2
Nishiguchi, M.3
-
6
-
-
0031933466
-
Assessment of trabecular structure using high resolution CT images and texture analysis
-
Link T.M., Majumdar S., Lin J.C., et al. Assessment of trabecular structure using high resolution CT images and texture analysis. J. Comput. Assist. Tomogr. 22 (1998) 15-24
-
(1998)
J. Comput. Assist. Tomogr.
, vol.22
, pp. 15-24
-
-
Link, T.M.1
Majumdar, S.2
Lin, J.C.3
-
7
-
-
0027409720
-
Quantitative image analysis of vertebral body architecture-improved diagnosis in osteoporosis based on high-resolution computed tomography
-
Mundinger A., Wiesmeier B., Dinkel E., Helwig A., Beck A., and Schulte Moenting J. Quantitative image analysis of vertebral body architecture-improved diagnosis in osteoporosis based on high-resolution computed tomography. Br. J. Radiol. 66 (1993) 209-213
-
(1993)
Br. J. Radiol.
, vol.66
, pp. 209-213
-
-
Mundinger, A.1
Wiesmeier, B.2
Dinkel, E.3
Helwig, A.4
Beck, A.5
Schulte Moenting, J.6
-
8
-
-
0034521722
-
Prediction of bone strength from cancellous structure of the distal radius: can we improve on DXA?
-
Wigderowitz C.A., Paterson C.R., Dashti H., McGurty D., and Rowley D.I. Prediction of bone strength from cancellous structure of the distal radius: can we improve on DXA?. Osteoporos. Int. 11 (2000) 840-846
-
(2000)
Osteoporos. Int.
, vol.11
, pp. 840-846
-
-
Wigderowitz, C.A.1
Paterson, C.R.2
Dashti, H.3
McGurty, D.4
Rowley, D.I.5
-
9
-
-
0031970444
-
Impact of spatial resolution on the prediction of trabecular architecture parameters
-
Kothari M., Keaveny T.M., Lin J.C., Newitt D.C., Genant H.K., and Majumdar S. Impact of spatial resolution on the prediction of trabecular architecture parameters. Bone 22 (1998) 437-443
-
(1998)
Bone
, vol.22
, pp. 437-443
-
-
Kothari, M.1
Keaveny, T.M.2
Lin, J.C.3
Newitt, D.C.4
Genant, H.K.5
Majumdar, S.6
-
10
-
-
33645062182
-
Structural analysis of trabecular bone of the proximal femur using multislice computed tomography: a comparison with dual X-ray absorptiometry for predicting biomechanical strength in vitro
-
Bauer J.S., Kohlmann S., Eckstein F., Mueller D., Lochmuller E.M., and Link T.M. Structural analysis of trabecular bone of the proximal femur using multislice computed tomography: a comparison with dual X-ray absorptiometry for predicting biomechanical strength in vitro. Calcif. Tissue Int. 78 (2006) 78-89
-
(2006)
Calcif. Tissue Int.
, vol.78
, pp. 78-89
-
-
Bauer, J.S.1
Kohlmann, S.2
Eckstein, F.3
Mueller, D.4
Lochmuller, E.M.5
Link, T.M.6
-
11
-
-
0031881740
-
A comparative study of trabecular bone properties in the spine and femur using high resolution MRI and CT
-
Link T.M., Majumdar S., Lin J.C., et al. A comparative study of trabecular bone properties in the spine and femur using high resolution MRI and CT. J. Bone Miner. Res. 13 (1998) 122-132
-
(1998)
J. Bone Miner. Res.
, vol.13
, pp. 122-132
-
-
Link, T.M.1
Majumdar, S.2
Lin, J.C.3
-
12
-
-
2642571066
-
[Multislice-CT for structure analysis of trabecular bone - a comparison with micro-CT and biomechanical strength]
-
Bauer J.S., Issever A.S., Fischbeck M., et al. [Multislice-CT for structure analysis of trabecular bone - a comparison with micro-CT and biomechanical strength]. Rofo 176 (2004) 709-718
-
(2004)
Rofo
, vol.176
, pp. 709-718
-
-
Bauer, J.S.1
Issever, A.S.2
Fischbeck, M.3
-
13
-
-
0038081023
-
High-resolution MRI vs multislice spiral CT: which technique depicts the trabecular bone structure best?
-
Link T.M., Vieth V., Stehling C., et al. High-resolution MRI vs multislice spiral CT: which technique depicts the trabecular bone structure best?. Eur. Radiol. 13 (2003) 663-671
-
(2003)
Eur. Radiol.
, vol.13
, pp. 663-671
-
-
Link, T.M.1
Vieth, V.2
Stehling, C.3
-
14
-
-
34250722588
-
Analysis of trabecular bone structure with multidetector spiral computed tomography in a simulated soft-tissue environment
-
Bauer J.S., Link T.M., Burghardt A., et al. Analysis of trabecular bone structure with multidetector spiral computed tomography in a simulated soft-tissue environment. Calcif. Tissue Int. 80 (2007) 366-373
-
(2007)
Calcif. Tissue Int.
, vol.80
, pp. 366-373
-
-
Bauer, J.S.1
Link, T.M.2
Burghardt, A.3
-
16
-
-
0029906959
-
Magnetic resonance imaging of trabecular bone structure in the distal radius: relationship with X-ray tomographic microscopy and biomechanics
-
Majumdar S., Newitt D., Mathur A., et al. Magnetic resonance imaging of trabecular bone structure in the distal radius: relationship with X-ray tomographic microscopy and biomechanics. Osteoporos. Int. 6 (1996) 376-385
-
(1996)
Osteoporos. Int.
, vol.6
, pp. 376-385
-
-
Majumdar, S.1
Newitt, D.2
Mathur, A.3
-
17
-
-
0023924540
-
Bone histomorphometry: standardization of nomenclature, symbols and units (summary of proposed system)
-
Parfitt A.M. Bone histomorphometry: standardization of nomenclature, symbols and units (summary of proposed system). Bone 9 (1988) 67-69
-
(1988)
Bone
, vol.9
, pp. 67-69
-
-
Parfitt, A.M.1
-
18
-
-
0023488581
-
Bone histomorphometry: standardization of nomenclature, symbols, and units. Report of the ASBMR Histomorphometry Nomenclature Committee
-
Parfitt A.M., Drezner M.K., Glorieux F.H., et al. Bone histomorphometry: standardization of nomenclature, symbols, and units. Report of the ASBMR Histomorphometry Nomenclature Committee. J. Bone Miner. Res. 2 (1987) 595-610
-
(1987)
J. Bone Miner. Res.
, vol.2
, pp. 595-610
-
-
Parfitt, A.M.1
Drezner, M.K.2
Glorieux, F.H.3
-
19
-
-
0344406113
-
Local differences in the trabecular bone structure of the proximal femur depicted with high-spatial-resolution MR imaging and multisection CT
-
Issever A.S., Vieth V., Lotter A., et al. Local differences in the trabecular bone structure of the proximal femur depicted with high-spatial-resolution MR imaging and multisection CT. Acad. Radiol. 9 (2002) 1395-1406
-
(2002)
Acad. Radiol.
, vol.9
, pp. 1395-1406
-
-
Issever, A.S.1
Vieth, V.2
Lotter, A.3
-
20
-
-
15744406055
-
Trabecular bone structure obtained from multislice spiral computed tomography of the calcaneus predicts osteoporotic vertebral deformities
-
Patel P.V., Prevrhal S., Bauer J.S., et al. Trabecular bone structure obtained from multislice spiral computed tomography of the calcaneus predicts osteoporotic vertebral deformities. J. Comput. Assist. Tomogr. 29 (2005) 246-253
-
(2005)
J. Comput. Assist. Tomogr.
, vol.29
, pp. 246-253
-
-
Patel, P.V.1
Prevrhal, S.2
Bauer, J.S.3
-
21
-
-
33646149773
-
Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference
-
Phan C.M., Matsuura M., Bauer J.S., et al. Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference. Radiology 239 (2006) 488-496
-
(2006)
Radiology
, vol.239
, pp. 488-496
-
-
Phan, C.M.1
Matsuura, M.2
Bauer, J.S.3
-
22
-
-
33847703730
-
Quantifying anisotropy of trabecular bone from gray-level images
-
Tabor Z., and Rokita E. Quantifying anisotropy of trabecular bone from gray-level images. Bone 40 (2007) 966-972
-
(2007)
Bone
, vol.40
, pp. 966-972
-
-
Tabor, Z.1
Rokita, E.2
-
24
-
-
0029371157
-
Evaluation of textural and multipolarization radar features for crop classification
-
Anys H., and He C. Evaluation of textural and multipolarization radar features for crop classification. IEEE 33 (1995) 1170-1181
-
(1995)
IEEE
, vol.33
, pp. 1170-1181
-
-
Anys, H.1
He, C.2
-
26
-
-
33745161509
-
Analysis of the topological properties of the proximal femur on a regional scale: Evaluation of multi-detector CT-scans for the assessment of biomechanical strength using local Minkowski functionals in 3D. San Diego
-
Boehm H, Link T, Monetti R. Analysis of the topological properties of the proximal femur on a regional scale: evaluation of multi-detector CT-scans for the assessment of biomechanical strength using local Minkowski functionals in 3D. San Diego: SPIE Medical Imaging; 2006, p. 6144-254.
-
(2006)
SPIE Medical Imaging
, pp. 6144-6254
-
-
Boehm, H.1
Link, T.2
Monetti, R.3
-
27
-
-
0038415879
-
Local 3D scaling properties for the analysis of trabecular bone extracted from high-resolution magnetic resonance imaging of human trabecular bone: comparison with bone mineral density in the prediction of biomechanical strength in vitro
-
Boehm H.F., Raeth C., Monetti R.A., et al. Local 3D scaling properties for the analysis of trabecular bone extracted from high-resolution magnetic resonance imaging of human trabecular bone: comparison with bone mineral density in the prediction of biomechanical strength in vitro. Invest. Radiol. 38 (2003) 269-280
-
(2003)
Invest. Radiol.
, vol.38
, pp. 269-280
-
-
Boehm, H.F.1
Raeth, C.2
Monetti, R.A.3
-
28
-
-
0032946288
-
[Bone densitometry by dual energy methods]
-
Felsenberg D., and Gowin W. [Bone densitometry by dual energy methods]. Radiologe 39 (1999) 186-193
-
(1999)
Radiologe
, vol.39
, pp. 186-193
-
-
Felsenberg, D.1
Gowin, W.2
-
29
-
-
3343026095
-
Relationship between computed tomographic image analysis and histomorphometry for microarchitectural characterization of human calcaneus
-
Cortet B., Chappard D., Boutry N., Dubois P., Cotten A., and Marchandise X. Relationship between computed tomographic image analysis and histomorphometry for microarchitectural characterization of human calcaneus. Calcif. Tissue Int. 75 (2004) 23-31
-
(2004)
Calcif. Tissue Int.
, vol.75
, pp. 23-31
-
-
Cortet, B.1
Chappard, D.2
Boutry, N.3
Dubois, P.4
Cotten, A.5
Marchandise, X.6
-
30
-
-
0036168001
-
Computed tomography image analysis of the calcaneus in male osteoporosis
-
Cortet B., Dubois P., Boutry N., Palos G., Cotten A., and Marchandise X. Computed tomography image analysis of the calcaneus in male osteoporosis. Osteoporos. Int. 13 (2002) 33-41
-
(2002)
Osteoporos. Int.
, vol.13
, pp. 33-41
-
-
Cortet, B.1
Dubois, P.2
Boutry, N.3
Palos, G.4
Cotten, A.5
Marchandise, X.6
-
31
-
-
36049045483
-
Monitoring teriparatide-associated changes in vertebral microstructure by high-resolution CT in vivo: results from the EUROFORS study
-
Graeff C., Timm W., Nickelsen T.N., et al. Monitoring teriparatide-associated changes in vertebral microstructure by high-resolution CT in vivo: results from the EUROFORS study. J. Bone Miner. Res. 22 (2007) 1426-1433
-
(2007)
J. Bone Miner. Res.
, vol.22
, pp. 1426-1433
-
-
Graeff, C.1
Timm, W.2
Nickelsen, T.N.3
-
32
-
-
14044280080
-
Relationship between compressive properties of human os calcis cancellous bone and microarchitecture assessed from 2D and 3D synchrotron microtomography
-
Follet H., Bruyere-Garnier K., Peyrin F., et al. Relationship between compressive properties of human os calcis cancellous bone and microarchitecture assessed from 2D and 3D synchrotron microtomography. Bone 36 (2005) 340-351
-
(2005)
Bone
, vol.36
, pp. 340-351
-
-
Follet, H.1
Bruyere-Garnier, K.2
Peyrin, F.3
-
33
-
-
38149084050
-
Evaluation of trabecular mechanical and microstructural properties in human calcaneal bone of advanced age using mechanical testing, microCT, and DXA
-
Mittra E., Rubin C., Gruber B., and Qin Y.X. Evaluation of trabecular mechanical and microstructural properties in human calcaneal bone of advanced age using mechanical testing, microCT, and DXA. J. Biomech. 41 (2008) 368-375
-
(2008)
J. Biomech.
, vol.41
, pp. 368-375
-
-
Mittra, E.1
Rubin, C.2
Gruber, B.3
Qin, Y.X.4
-
34
-
-
0035140632
-
Predictive value of bone mineral density and morphology determined by peripheral quantitative computed tomography for cancellous bone strength of the proximal femur
-
Wachter N.J., Augat P., Mentzel M., et al. Predictive value of bone mineral density and morphology determined by peripheral quantitative computed tomography for cancellous bone strength of the proximal femur. Bone 28 (2001) 133-139
-
(2001)
Bone
, vol.28
, pp. 133-139
-
-
Wachter, N.J.1
Augat, P.2
Mentzel, M.3
-
35
-
-
0035075072
-
Does the trabecular bone structure depicted by high-resolution MRI of the calcaneus reflect the true bone structure?
-
Vieth V., Link T.M., Lotter A., et al. Does the trabecular bone structure depicted by high-resolution MRI of the calcaneus reflect the true bone structure?. Invest. Radiol. 36 (2001) 210-217
-
(2001)
Invest. Radiol.
, vol.36
, pp. 210-217
-
-
Vieth, V.1
Link, T.M.2
Lotter, A.3
-
36
-
-
0033692878
-
Changes in calcaneal trabecular bone structure after heart transplantation: an MR imaging study
-
Link T.M., Lotter A., Beyer F., et al. Changes in calcaneal trabecular bone structure after heart transplantation: an MR imaging study. Radiology 217 (2000) 855-862
-
(2000)
Radiology
, vol.217
, pp. 855-862
-
-
Link, T.M.1
Lotter, A.2
Beyer, F.3
-
37
-
-
0031837398
-
In vivo high resolution MRI of the calcaneus: differences in trabecular structure in osteoporosis patients
-
Link T.M., Majumdar S., Augat P., et al. In vivo high resolution MRI of the calcaneus: differences in trabecular structure in osteoporosis patients. J. Bone Miner. Res. 13 (1998) 1175-1182
-
(1998)
J. Bone Miner. Res.
, vol.13
, pp. 1175-1182
-
-
Link, T.M.1
Majumdar, S.2
Augat, P.3
-
38
-
-
0031704168
-
Fractal analysis of trabecular bone texture on radiographs: discriminant value in postmenopausal osteoporosis
-
Pothuaud L., Lespessailles E., Harba R., et al. Fractal analysis of trabecular bone texture on radiographs: discriminant value in postmenopausal osteoporosis. Osteoporos. Int. 8 (1998) 618-625
-
(1998)
Osteoporos. Int.
, vol.8
, pp. 618-625
-
-
Pothuaud, L.1
Lespessailles, E.2
Harba, R.3
-
39
-
-
0031087395
-
Texture analysis of direct magnification radiographs of vertebral specimens: correlation with bone mineral density and biomechanical properties
-
Link T.M., Majumdar S., Konermann W., et al. Texture analysis of direct magnification radiographs of vertebral specimens: correlation with bone mineral density and biomechanical properties. Acad. Radiol. 4 (1997) 167-176
-
(1997)
Acad. Radiol.
, vol.4
, pp. 167-176
-
-
Link, T.M.1
Majumdar, S.2
Konermann, W.3
|