메뉴 건너뛰기




Volumn 6, Issue 5, 1996, Pages 376-385

Magnetic resonance imaging of trabecular bone structure in the distal radius: Relationship with X-ray tomographic microscopy and biomechanics

Author keywords

Architecture; Magnetic resonance; Microscopy; Osteoporosis; Trabecular bone

Indexed keywords

ARTICLE; BIOMECHANICS; BONE DENSITY; BONE MINERAL; BONE STRENGTH; BONE STRUCTURE; HUMAN; MICROSCOPY; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOPOROSIS; PRIORITY JOURNAL; RADIUS; TRABECULAR BONE; YOUNG MODULUS;

EID: 0029906959     PISSN: 0937941X     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF01623011     Document Type: Article
Times cited : (167)

References (19)
  • 2
    • 0342592361 scopus 로고    scopus 로고
    • Morpho- Metric analysis of non-invasively assessed bone biopsies: Comparison of high resolution computed tomography and histologic sections
    • Muller R, Hahn M, Vogel M, Delling G, Ruegsegger P. Morpho- metric analysis of non-invasively assessed bone biopsies: comparison of high resolution computed tomography and histologic sections. Bone 1996;8:215.
    • (1996) Bone , vol.8 , pp. 215
    • Muller, R.1    Hahn, M.2    Vogel, M.3    Delling, G.4    Ruegsegger, P.5
  • 3
    • 0028153803 scopus 로고
    • Non-invasive bone biopsy: A new method to analyze and display three dimensional structure of trabecular bone
    • Muller R, Hildebrand T, Ruegsegger P. Non-invasive bone biopsy: a new method to analyze and display three dimensional structure of trabecular bone. Phys Med Biol 1994;39:145.
    • (1994) Phys Med Biol , vol.39 , pp. 145
    • Muller, R.1    Hildebrand, T.2    Ruegsegger, P.3
  • 5
    • 0028910321 scopus 로고
    • In vivo, three dimensional microscopy of trabecular bone
    • Kinney JH, Lane NE, Haupt DL. In vivo, three dimensional microscopy of trabecular bone. J Bone Miner Res 1995;10:264.
    • (1995) J Bone Miner Res , vol.10 , pp. 264
    • Kinney, J.H.1    Lane, N.E.2    Haupt, D.L.3
  • 6
    • 0028867759 scopus 로고
    • Evaluation of technical factors affecting the quntitation of trabecular bone structure using magnetic resonance imaging
    • Majumdar S, Newitt D, Jergas M, Gies A, Chiu E, Osman D, et al. Evaluation of technical factors affecting the quntitation of trabecular bone structure using magnetic resonance imaging. Bone 1995;17:417.
    • (1995) Bone , vol.17 , pp. 417
    • Majumdar, S.1    Newitt, D.2    Jergas, M.3    Gies, A.4    Chiu, E.5    Osman, D.6
  • 7
    • 0028946377 scopus 로고
    • Quantitative analysis of trabecular microstracture by 400 MHz nuclear magnetic resonance imaging
    • Chung HW, Wehrli FW, Williams JL, Kugelmass SD, Wehrli S. Quantitative analysis of trabecular microstracture by 400 MHz nuclear magnetic resonance imaging. J Bone Miner Res 1995;10:803.
    • (1995) J Bone Miner Res , vol.10 , pp. 803
    • Chung, H.W.1    Wehrli, F.W.2    Williams, J.L.3    Kugelmass, S.D.4    Wehrli, S.5
  • 10
    • 0027205520 scopus 로고
    • Prescision and accuracy for rat whole body and femur bone mineral determination with dual X-ray absorptiometry
    • Hagiwara S, Lane N, Engelke K, Sebastian A, Kimmell DB, Genant HK. Prescision and accuracy for rat whole body and femur bone mineral determination with dual X-ray absorptiometry. Bone Miner 1993;22:57.
    • (1993) Bone Miner , vol.22 , pp. 57
    • Hagiwara, S.1    Lane, N.2    Engelke, K.3    Sebastian, A.4    Kimmell, D.B.5    Genant, H.K.6
  • 11
    • 0002672224 scopus 로고
    • Xray tomographic microscopy (XTM) using synchrotron radiation
    • Kinney JH, Nichols MC. Xray tomographic microscopy (XTM) using synchrotron radiation. Annu Rev Mater Sci 1992;22:121.
    • (1992) Annu Rev Mater Sci , vol.22 , pp. 121
    • Kinney, J.H.1    Nichols, M.C.2
  • 12
    • 0026574430 scopus 로고
    • High-resolution MR imaging of the wrist and eye with short TR, short TE, and partial-echo acquisition
    • Foo TK, Shellock FG, Hayes CE, Schenck JF, Slayman BE. High-resolution MR imaging of the wrist and eye with short TR, short TE, and partial-echo acquisition. Radiology 1992;183:277.
    • (1992) Radiology , vol.183 , pp. 277
    • Foo, T.K.1    Shellock, F.G.2    Hayes, C.E.3    Schenck, J.F.4    Slayman, B.E.5
  • 13
    • 0017252850 scopus 로고
    • The distribution of cortical and trabecular bone mass along the lengths of the radius and ulna and the implications for in vivo bone mass measurements
    • Schlenker RA, Von Seggen WW. The distribution of cortical and trabecular bone mass along the lengths of the radius and ulna and the implications for in vivo bone mass measurements. Calcif Tissue Res 1976;20:41.
    • (1976) Calcif Tissue Res , vol.20 , pp. 41
    • Schlenker, R.A.1    Von Seggen, W.W.2
  • 14
    • 0023880239 scopus 로고
    • Mechanical properties of bone by a non-destructive compression testing approach
    • Linde F, Gothgen CB, Hvid I, Pongsoipetch B, Bentzen S. Mechanical properties of bone by a non-destructive compression testing approach. Eng Med 1988;17:23.
    • (1988) Eng Med , vol.17 , pp. 23
    • Linde, F.1    Gothgen, C.B.2    Hvid, I.3    Pongsoipetch, B.4    Bentzen, S.5
  • 17
    • 0027413855 scopus 로고
    • High-resolution variable flip angle 3D MR imaging of trabecular microstructure in vivo
    • Jara H, Wehrli FW, Chung H, Ford JC. High-resolution variable flip angle 3D MR imaging of trabecular microstructure in vivo. Magn Reson Med 1993;29:528.
    • (1993) Magn Reson Med , vol.29 , pp. 528
    • Jara, H.1    Wehrli, F.W.2    Chung, H.3    Ford, J.C.4
  • 19
    • 10244222410 scopus 로고
    • In vivo assessment of three dimensional structural properties of cancellous bone: A reproducibility study
    • Muller R, Ruegsegger P. In vivo assessment of three dimensional structural properties of cancellous bone: a reproducibility study. Eleventh International Bone Densitometry Workshop. 1995:73.
    • (1995) Eleventh International Bone Densitometry Workshop , pp. 73
    • Muller, R.1    Ruegsegger, P.2