Volumn 67, Issue 1, 2009, Pages 19-24

Tilt-induced changes in haemodynamic parameters in patients with cardiac resynchronisation therapy - A pilot study

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CARDIAC RESYNCHRONIZATION THERAPY; CLINICAL ARTICLE; HEART CYCLE; HEART HEMODYNAMICS; HEART LEFT VENTRICLE EJECTION FRACTION; HEART OUTPUT; HEART STROKE VOLUME; HUMAN; PILOT STUDY; SUPINE POSITION; VASCULAR RESISTANCE;

EID: 63049099459     PISSN: 00229032     EISSN: 00229032     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (17)
  • 1
    • 38649123223 scopus 로고    scopus 로고
    • Guidelines for cardiac pacing and cardiac resynchronization therapy
    • Vardas PE, Auricchio A, Blanc JJ, et al. Guidelines for cardiac pacing and cardiac resynchronization therapy. Europace 2007; 9: 959-98.
    • (2007) Europace , vol.9 , pp. 959-998
    • Vardas, P.E.1    Auricchio, A.2    Blanc, J.J.3
  • 2
    • 26944480058 scopus 로고    scopus 로고
    • Tailored echocardiographic interventricular delay programming further optimizes left ventricular performance after cardiac resynchronization therapy
    • Vanderheyden M, Backer TD, Rivero-Ayerza M, et al. Tailored echocardiographic interventricular delay programming further optimizes left ventricular performance after cardiac resynchronization therapy. Heart Rhythm 2005; 2: 1066-72.
    • (2005) Heart Rhythm , vol.2 , pp. 1066-1072
    • Vanderheyden, M.1    Backer, T.D.2    Rivero-Ayerza, M.3
  • 3
    • 3042825523 scopus 로고    scopus 로고
    • Beyond the four quadrants: The critical and emerging role of impedance cardiography in heart failure
    • Strobeck J, Silver M. Beyond the four quadrants: the critical and emerging role of impedance cardiography in heart failure. Congest Heart Fail 2004; 10 (supl. 2): 1-6.
    • (2004) Congest Heart Fail , vol.10 , Issue.SUPL. 2 , pp. 1-6
    • Strobeck, J.1    Silver, M.2
  • 4
    • 0030701597 scopus 로고    scopus 로고
    • Optimizing the AV delay in DDD pacemaker patients with high degree AV block: Mitral valve Doppler versus impedance cardiography
    • Kindermann M, Frohlig G, Doerr T, et al. Optimizing the AV delay in DDD pacemaker patients with high degree AV block: mitral valve Doppler versus impedance cardiography. Pacing Clin Electrophysiol 1997; 20: 2453-62.
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 2453-2462
    • Kindermann, M.1    Frohlig, G.2    Doerr, T.3
  • 5
    • 4344683588 scopus 로고    scopus 로고
    • Holter-type impedance cardiography device. A system for continuous and non-invasive monitoring of cardiac haemodynamics
    • Cybulski G, Kozluk E, Michalak E, et al. Holter-type impedance cardiography device. A system for continuous and non-invasive monitoring of cardiac haemodynamics. Kardiol Pol 2004; 61: 138-46.
    • (2004) Kardiol Pol , vol.61 , pp. 138-146
    • Cybulski, G.1    Kozluk, E.2    Michalak, E.3
  • 6
    • 25444523480 scopus 로고    scopus 로고
    • Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy
    • Braun MU, Schnabel A, Rauwolf T, et al. Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy. J Interv Card Electrophysiol 2005; 13: 223-9.
    • (2005) J Interv Card Electrophysiol , vol.13 , pp. 223-229
    • Braun, M.U.1    Schnabel, A.2    Rauwolf, T.3
  • 7
    • 0037247636 scopus 로고    scopus 로고
    • Impedance cardiography for atrioventricular interval optimization during permanent left ventricular pacing
    • Tse H, Yu C, Park E, et al. Impedance cardiography for atrioventricular interval optimization during permanent left ventricular pacing. Pacing Clin Electrophysiol 2003; 26: 189-91.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 189-191
    • Tse, H.1    Yu, C.2    Park, E.3
  • 8
    • 24944488027 scopus 로고    scopus 로고
    • Method and demonstration of direct confirmation of response to cardiac resynchronization therapy via preimplant temporary biventricular pacing and impedance cardiography
    • Gimbel JR. Method and demonstration of direct confirmation of response to cardiac resynchronization therapy via preimplant temporary biventricular pacing and impedance cardiography. Am J Cardiol 2005; 96: 874-6.
    • (2005) Am J Cardiol , vol.96 , pp. 874-876
    • Gimbel, J.R.1
  • 9
    • 63049115845 scopus 로고    scopus 로고
    • Biventricular pacing with left to right ventricle pacing delay - the acute hemodynamic effect
    • Kutarski A, Rucihski P, Sodolski T, et al. Biventricular pacing with left to right ventricle pacing delay - the acute hemodynamic effect. Europace 2005; 7: 301.
    • (2005) Europace , vol.7 , pp. 301
    • Kutarski, A.1    Rucihski, P.2    Sodolski, T.3
  • 10
    • 38749090601 scopus 로고    scopus 로고
    • The role of repeating optimization of atrioventricular interval during interim and long-term follow-up after cardiac resynchronization therapy
    • Zhang Q, Fung JW, Chan YS, et al. The role of repeating optimization of atrioventricular interval during interim and long-term follow-up after cardiac resynchronization therapy. Int J Cardiol 2008; 124: 211-7.
    • (2008) Int J Cardiol , vol.124 , pp. 211-217
    • Zhang, Q.1    Fung, J.W.2    Chan, Y.S.3
  • 11
    • 34548516162 scopus 로고    scopus 로고
    • Impedance cardiography: A useful and reliable tool in optimization of cardiac resynchronization devices
    • Heinroth KM, Elster M, Nuding S, et al. Impedance cardiography: a useful and reliable tool in optimization of cardiac resynchronization devices. Eurpace 2007; 9: 744-50.
    • (2007) Eurpace , vol.9 , pp. 744-750
    • Heinroth, K.M.1    Elster, M.2    Nuding, S.3
  • 12
    • 33747840723 scopus 로고    scopus 로고
    • Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement
    • Fortin J, Habenbacher W, Heller A, et al. Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement. Comput Biol Med 2006; 36: 1185-203.
    • (2006) Comput Biol Med , vol.36 , pp. 1185-1203
    • Fortin, J.1    Habenbacher, W.2    Heller, A.3
  • 14
    • 6344278408 scopus 로고    scopus 로고
    • Stroke volume and systolic time intervals: Beat-to- beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions
    • Cybulski G, Michalak E, Koźluk E, et al. Stroke volume and systolic time intervals: beat-to- beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions. Med Biol Eng Comp 2004; 42: 707-11.
    • (2004) Med Biol Eng Comp , vol.42 , pp. 707-711
    • Cybulski, G.1    Michalak, E.2    Koźluk, E.3
  • 15
    • 0033824085 scopus 로고    scopus 로고
    • Biventricular pacing in end-stage heart failure improves functional capacity and left ventricular function
    • Bakker P, Meijburg H, de Vries JW, et al. Biventricular pacing in end-stage heart failure improves functional capacity and left ventricular function. J Interv Cardiol 2000; 4: 395-404.
    • (2000) J Interv Cardiol , vol.4 , pp. 395-404
    • Bakker, P.1    Meijburg, H.2    de Vries, J.W.3
  • 16
    • 33645120456 scopus 로고    scopus 로고
    • Myocardial contractility and cardiac filling measured by impedance cardiography in patients with nitroglycerine-induced vasovagal syncope
    • Mitro P, Hijova E. Myocardial contractility and cardiac filling measured by impedance cardiography in patients with nitroglycerine-induced vasovagal syncope. Pacing Clin Electrophysiol 2006; 29: 1-8.
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 1-8
    • Mitro, P.1    Hijova, E.2
  • 17
    • 34247501287 scopus 로고    scopus 로고
    • Investigation of various types of neurocardiogenic response to head-up tilting by extended hemodynamic and neurohormonal monitoring
    • Nowak L, Nowak FG, Janko S, et al. Investigation of various types of neurocardiogenic response to head-up tilting by extended hemodynamic and neurohormonal monitoring. Pacing Clin Electrophysiol 2007; 30: 623-30.
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 623-630
    • Nowak, L.1    Nowak, F.G.2    Janko, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.