-
1
-
-
0036584937
-
Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation
-
Lotz J, Meier C, Leppert A, Galanski M. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Ra-dioGraphics 2002; 22:651-671
-
(2002)
Ra-dioGraphics
, vol.22
, pp. 651-671
-
-
Lotz, J.1
Meier, C.2
Leppert, A.3
Galanski, M.4
-
2
-
-
0029351712
-
Flow quantification and analysis methods
-
Pelc NJ. Flow quantification and analysis methods. Magn Reson Imaging Clin N Am 1995; 3: 413-424
-
(1995)
Magn Reson Imaging Clin N Am
, vol.3
, pp. 413-424
-
-
Pelc, N.J.1
-
3
-
-
0034763259
-
Pulmonary venous flow velocity patterns in 404 individuals without cardiovascular disease
-
de Marchi SF, Bodenmuller M, Lai DL, Seiler C. Pulmonary venous flow velocity patterns in 404 individuals without cardiovascular disease. Heart 2001; 85:23-29
-
(2001)
Heart
, vol.85
, pp. 23-29
-
-
de Marchi, S.F.1
Bodenmuller, M.2
Lai, D.L.3
Seiler, C.4
-
4
-
-
0034797484
-
Doppler velocimetry in superior vena cava provides useful information on the right circulatory function in patients with congestive heart failure
-
Ghio S, Recusani F, Sebastiani R, et al. Doppler velocimetry in superior vena cava provides useful information on the right circulatory function in patients with congestive heart failure. Echocar-diography 2001; 18:469-477
-
(2001)
Echocar-diography
, vol.18
, pp. 469-477
-
-
Ghio, S.1
Recusani, F.2
Sebastiani, R.3
-
5
-
-
0025153107
-
Vena caval flow: Assessment with cine MR velocity mapping
-
Mohiaddin RH, Wann SL, Underwood R, Firmin DN, Rees S, Longmore DB. Vena caval flow: assessment with cine MR velocity mapping. Radiology 1990; 177:537-541
-
(1990)
Radiology
, vol.177
, pp. 537-541
-
-
Mohiaddin, R.H.1
Wann, S.L.2
Underwood, R.3
Firmin, D.N.4
Rees, S.5
Longmore, D.B.6
-
6
-
-
0030922875
-
Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: In vitro and in vivo validation
-
Lee VS, Spritzer CE, Carroll BA, et al. Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation. AJR 1997; 169:1125-1131
-
(1997)
AJR
, vol.169
, pp. 1125-1131
-
-
Lee, V.S.1
Spritzer, C.E.2
Carroll, B.A.3
-
7
-
-
0030065280
-
Accuracy of maximum velocity estimates made using Doppler ultrasound systems
-
Hoskins PR. Accuracy of maximum velocity estimates made using Doppler ultrasound systems. Br J Radiol 1996; 69:172-177
-
(1996)
Br J Radiol
, vol.69
, pp. 172-177
-
-
Hoskins, P.R.1
-
8
-
-
0027497819
-
Magnetic resonance imaging of blood flow with a phase subtraction technique: In vitro and in vivo validation
-
Evans AJ, Iwai F, Grist TA, et al. Magnetic resonance imaging of blood flow with a phase subtraction technique: in vitro and in vivo validation. Invest Radiol 1993; 28:109-115
-
(1993)
Invest Radiol
, vol.28
, pp. 109-115
-
-
Evans, A.J.1
Iwai, F.2
Grist, T.A.3
-
9
-
-
0024953766
-
Accuracy of the simplified Bernoulli relationship in measuring pressure gradients across stenosis
-
Rieu R, Pelissier R, Isaaz K. Accuracy of the simplified Bernoulli relationship in measuring pressure gradients across stenosis. Int Angiol 1989;8:210-215
-
(1989)
Int Angiol
, vol.8
, pp. 210-215
-
-
Rieu, R.1
Pelissier, R.2
Isaaz, K.3
-
10
-
-
0030454430
-
Improved measurement of pressure gradients in aortic coarctation by magnetic resonance imaging
-
Oshinski JN, Parks WJ, Markou CP, et al. Improved measurement of pressure gradients in aortic coarctation by magnetic resonance imaging. J Am Coll Cardiol 1996; 28:1818-1826
-
(1996)
J Am Coll Cardiol
, vol.28
, pp. 1818-1826
-
-
Oshinski, J.N.1
Parks, W.J.2
Markou, C.P.3
-
11
-
-
0028122164
-
Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging
-
Steffens JC, Bourne MW, Sakuma H, O'Sullivan M, Higgins CB. Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging. Circulation 1994; 90:937-943
-
(1994)
Circulation
, vol.90
, pp. 937-943
-
-
Steffens, J.C.1
Bourne, M.W.2
Sakuma, H.3
O'Sullivan, M.4
Higgins, C.B.5
-
12
-
-
0037843159
-
Management of grown up congenital heart disease
-
Deanfield J, Thaulow E, Warnes C, et al. Management of grown up congenital heart disease. Eur Heart J 2003; 24:1035-1084
-
(2003)
Eur Heart J
, vol.24
, pp. 1035-1084
-
-
Deanfield, J.1
Thaulow, E.2
Warnes, C.3
-
13
-
-
0034435744
-
Phase-contrast cine MR angiography detection of thoracic aortic dissection
-
Silverman JM, Raissi S, Tyszka JM, Trento A, Herfkens RJ. Phase-contrast cine MR angiography detection of thoracic aortic dissection. Int J Card Imaging 2000; 16:461-470
-
(2000)
Int J Card Imaging
, vol.16
, pp. 461-470
-
-
Silverman, J.M.1
Raissi, S.2
Tyszka, J.M.3
Trento, A.4
Herfkens, R.J.5
-
14
-
-
36749063034
-
Budisav- ljevic MN. Nephrogenic systemic fibrosis after exposure to gadolinium in patients with renal failure
-
Othersen JB, Maize JC, Woolson RF, Budisav- ljevic MN. Nephrogenic systemic fibrosis after exposure to gadolinium in patients with renal failure. Nephrol Dial Transplant 2007; 22:3179-3185
-
(2007)
Nephrol Dial Transplant
, vol.22
, pp. 3179-3185
-
-
Othersen, J.B.1
Maize, J.C.2
Woolson, R.F.3
-
15
-
-
1942437370
-
Assessment of chronic aortic dissection: Contribution of different ECG-gated breath-hold MRI techniques
-
Kunz RP, Oberholzer K, Kuroczynski W, et al. Assessment of chronic aortic dissection: contribution of different ECG-gated breath-hold MRI techniques. AJR 2004; 182:1319-1326
-
(2004)
AJR
, vol.182
, pp. 1319-1326
-
-
Kunz, R.P.1
Oberholzer, K.2
Kuroczynski, W.3
-
16
-
-
0036651430
-
Quantification of flow dynamics in congenital heart disease: Applications of velocity-encoded cine MR imaging
-
Varaprasathan GA, Araoz PA, Higgins CB, Red- dy GP. Quantification of flow dynamics in congenital heart disease: applications of velocity-encoded cine MR imaging. RadioGraphics 2002;22:895-905
-
(2002)
RadioGraphics
, vol.22
, pp. 895-905
-
-
Varaprasathan, G.A.1
Araoz, P.A.2
Higgins, C.B.3
Red- dy, G.P.4
-
17
-
-
0028852729
-
Carotid artery stenosis: Clinical efficacy of MR phase-contrast flow quantification as an adjunct to MR angiography
-
Vanninen RL, Manninen HI, Partanen PL, Vainio PA, Soimakallio S. Carotid artery stenosis: clinical efficacy of MR phase-contrast flow quantification as an adjunct to MR angiography. Radiology 1995; 194:459-467
-
(1995)
Radiology
, vol.194
, pp. 459-467
-
-
Vanninen, R.L.1
Manninen, H.I.2
Partanen, P.L.3
Vainio, P.A.4
Soimakallio, S.5
-
18
-
-
0033661966
-
Preoperative MRA flow quantification in CEA patients: Flow differences between patients who develop cerebral ischemia and patients who do not develop cerebral ischemia during cross-clamping of the carotid artery
-
Rutgers DR, Blankensteijn JD, van der Grond J. Preoperative MRA flow quantification in CEA patients: flow differences between patients who develop cerebral ischemia and patients who do not develop cerebral ischemia during cross-clamping of the carotid artery. Stroke 2000; 31:3021-3028
-
(2000)
Stroke
, vol.31
, pp. 3021-3028
-
-
Rutgers, D.R.1
Blankensteijn, J.D.2
van der Grond, J.3
-
19
-
-
0036732563
-
Contrast-enhanced 2D cine phase MR angiography for measurement of basilar artery blood flow in posterior circulation ischemia
-
Kato T, Indo T, Yoshida E, Iwasaki Y, Sone M, Sobue G. Contrast-enhanced 2D cine phase MR angiography for measurement of basilar artery blood flow in posterior circulation ischemia. Am J Neuroradiol 2002; 23:1346-1351
-
(2002)
Am J Neuroradiol
, vol.23
, pp. 1346-1351
-
-
Kato, T.1
Indo, T.2
Yoshida, E.3
Iwasaki, Y.4
Sone, M.5
Sobue, G.6
-
20
-
-
0025882906
-
Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: In vitro and in vivo validation
-
Kondo C, Caputo GR, Semelka R, Foster E, Shi-makawa A, Higgins CB. Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: in vitro and in vivo validation. AJR 1991; 157:9-16
-
(1991)
AJR
, vol.157
, pp. 9-16
-
-
Kondo, C.1
Caputo, G.R.2
Semelka, R.3
Foster, E.4
Shi-makawa, A.5
Higgins, C.B.6
-
21
-
-
0023236968
-
In vivo validation of MR velocity imaging
-
Firmin DN, Nayler GL, Klipstein RH, Underwood SR, Rees RS, Longmore DB. In vivo validation of MR velocity imaging. J Comput Assist Tomogr 1987; 11:751-756
-
(1987)
J Comput Assist Tomogr
, vol.11
, pp. 751-756
-
-
Firmin, D.N.1
Nayler, G.L.2
Klipstein, R.H.3
Underwood, S.R.4
Rees, R.S.5
Longmore, D.B.6
-
22
-
-
34548525319
-
How to diagnose diastolic heart failure: A consensus statement on the diagnosis of heart failure with normal left ventricular ejection fraction by the Heart Failure and Echocardiography Associations of the European Society of Cardiology
-
Paulus WJ, Tschope C, Sanderson JE, et al. How to diagnose diastolic heart failure: a consensus statement on the diagnosis of heart failure with normal left ventricular ejection fraction by the Heart Failure and Echocardiography Associations of the European Society of Cardiology. Eur Heart J 2007; 28:2539-2550
-
(2007)
Eur Heart J
, vol.28
, pp. 2539-2550
-
-
Paulus, W.J.1
Tschope, C.2
Sanderson, J.E.3
-
23
-
-
0036348525
-
Assessment of diastolic function by cardiovascular magnetic resonance
-
Paelinck BP, Lamb HJ, Bax JJ, Van der Wall EE, de Roos A. Assessment of diastolic function by cardiovascular magnetic resonance. Am Heart J 2002; 144:198-205
-
(2002)
Am Heart J
, vol.144
, pp. 198-205
-
-
Paelinck, B.P.1
Lamb, H.J.2
Bax, J.J.3
Van der Wall, E.E.4
de Roos, A.5
-
24
-
-
15944378916
-
Feasibility of tissue magnetic resonance imaging: A pilot study in comparison with tissue Doppler imaging and invasive measurement
-
Paelinck BP, de Roos A, Bax JJ, et al. Feasibility of tissue magnetic resonance imaging: a pilot study in comparison with tissue Doppler imaging and invasive measurement. J Am Coll Cardiol 2005; 45:1109-1116
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 1109-1116
-
-
Paelinck, B.P.1
de Roos, A.2
Bax, J.J.3
-
25
-
-
33746878785
-
Comparison of myocardial velocities obtained with magnetic resonance phase velocity mapping and tissue Doppler imaging in normal subjects and patients with left ventricular dyssynchrony
-
Delfino JG, Bhasin M, Cole R, et al. Comparison of myocardial velocities obtained with magnetic resonance phase velocity mapping and tissue Doppler imaging in normal subjects and patients with left ventricular dyssynchrony. J Magn Reson Imaging 2006; 24:304-311
-
(2006)
J Magn Reson Imaging
, vol.24
, pp. 304-311
-
-
Delfino, J.G.1
Bhasin, M.2
Cole, R.3
-
26
-
-
33646271588
-
Assessment of left ventricular dyssynchrony in patients with conduction delay and idiopathic dilated cardiomyopathy: Head-to-head comparison between tissue Doppler imaging and velocity-encoded magnetic resonance imaging
-
Westenberg JJ, Lamb HJ, van der Geest RJ, et al. Assessment of left ventricular dyssynchrony in patients with conduction delay and idiopathic dilated cardiomyopathy: head-to-head comparison between tissue Doppler imaging and velocity-encoded magnetic resonance imaging. J Am Coll Cardiol 2006; 47:2042-2048
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 2042-2048
-
-
Westenberg, J.J.1
Lamb, H.J.2
van der Geest, R.J.3
-
27
-
-
0027443677
-
Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot: Volumetric quantitation by nuclear magnetic resonance velocity mapping
-
Rebergen SA, Chin JG, Ottenkamp J, van der Wall EE, de Roos A. Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot: volumetric quantitation by nuclear magnetic resonance velocity mapping. Circulation 1993; 88:2257-2266
-
(1993)
Circulation
, vol.88
, pp. 2257-2266
-
-
Rebergen, S.A.1
Chin, J.G.2
Ottenkamp, J.3
van der Wall, E.E.4
de Roos, A.5
-
28
-
-
0034266456
-
Detection and quantification of valvular heart disease with dynamic cardiac MR imaging
-
Didier D, Ratib O, Lerch R, Friedli B. Detection and quantification of valvular heart disease with dynamic cardiac MR imaging. RadioGraphics 2000; 20:1279-1299
-
(2000)
RadioGraphics
, vol.20
, pp. 1279-1299
-
-
Didier, D.1
Ratib, O.2
Lerch, R.3
Friedli, B.4
-
29
-
-
0042264979
-
Evaluation of cardiac valvular disease with MR imaging: Qualitative and quantitative techniques
-
Glockner JF, Johnston DL, McGee KP. Evaluation of cardiac valvular disease with MR imaging: qualitative and quantitative techniques. Radio-Graphics 2003; 23:e9
-
(2003)
Radio-Graphics
, vol.23
-
-
Glockner, J.F.1
Johnston, D.L.2
McGee, K.P.3
-
30
-
-
0030451912
-
Right ventricular diastolic function in children with pulmonary regurgitation after repair of tetralogy of Fallot: Volumetric evaluation by magnetic resonance velocity mapping
-
Helbing WA, Niezen RA, Le Cessie S, van der Geest RJ, Ottenkamp J, de Roos A. Right ventricular diastolic function in children with pulmonary regurgitation after repair of tetralogy of Fallot: volumetric evaluation by magnetic resonance velocity mapping. J Am Coll Cardiol 1996;28:1827-1835
-
(1996)
J Am Coll Cardiol
, vol.28
, pp. 1827-1835
-
-
Helbing, W.A.1
Niezen, R.A.2
Le Cessie, S.3
van der Geest, R.J.4
Ottenkamp, J.5
de Roos, A.6
-
31
-
-
37349018290
-
Determination of peak velocity in stenotic areas: Echocardiography versus κ-t SENSE accelerated MR Fourier velocity encoding
-
Baltes C, Hansen MS, Tsao J, et al. Determination of peak velocity in stenotic areas: echocardiography versus κ-t SENSE accelerated MR Fourier velocity encoding. Radiology 2008; 246:249-257
-
(2008)
Radiology
, vol.246
, pp. 249-257
-
-
Baltes, C.1
Hansen, M.S.2
Tsao, J.3
-
32
-
-
0027980650
-
Mitral annular function assessed by 3D imaging for mitral valve surgery
-
Komoda T, Hetzer R, Uyama C, et al. Mitral annular function assessed by 3D imaging for mitral valve surgery. J Heart Valve Dis 1994; 3:483-490
-
(1994)
J Heart Valve Dis
, vol.3
, pp. 483-490
-
-
Komoda, T.1
Hetzer, R.2
Uyama, C.3
-
33
-
-
0031412992
-
MR velocity mapping of tricuspid flow: Correction for through-plane motion
-
Kayser HW, Stoel BC, van der Wall EE, van der Geest RJ, de Roos A. MR velocity mapping of tricuspid flow: correction for through-plane motion. J Magn Reson Imaging 1997; 7:669-673
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 669-673
-
-
Kayser, H.W.1
Stoel, B.C.2
van der Wall, E.E.3
van der Geest, R.J.4
de Roos, A.5
-
34
-
-
14644432375
-
Accurate quantitation of regurgitant volume with MRI in patients selected for mitral valve repair
-
Westenberg JJ, Doornbos J, Versteegh MI, et al. Accurate quantitation of regurgitant volume with MRI in patients selected for mitral valve repair. Eur J Cardiothorac Surg 2005; 27:462-466
-
(2005)
Eur J Cardiothorac Surg
, vol.27
, pp. 462-466
-
-
Westenberg, J.J.1
Doornbos, J.2
Versteegh, M.I.3
-
35
-
-
0034011243
-
Motion correction for the quantification of mitral regurgitation using the control volume method
-
Walker PG, Houlind K, Djurhuus C, Kim WY, Pedersen EM. Motion correction for the quantification of mitral regurgitation using the control volume method. Magn Reson Med 2000;43:726-733
-
(2000)
Magn Reson Med
, vol.43
, pp. 726-733
-
-
Walker, P.G.1
Houlind, K.2
Djurhuus, C.3
Kim, W.Y.4
Pedersen, E.M.5
-
36
-
-
0029101334
-
Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques
-
Hundley WG, Li HF, Willard JE, et al. Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques. Circulation 1995; 92:1151-1158
-
(1995)
Circulation
, vol.92
, pp. 1151-1158
-
-
Hundley, W.G.1
Li, H.F.2
Willard, J.E.3
|