Volumn 69, Issue 4, 2009, Pages 877-882

Assessment of end-tidal carbon dioxide during pediatric and adult sedation for endoscopic procedures

Author keywords

[No Author keywords available]

Indexed keywords

CARBON DIOXIDE; FENTANYL; KETAMINE; MIDAZOLAM; OXYGEN; PROPOFOL;

EID: 62949172019     PISSN: 00165107     EISSN: 10976779     Source Type: Journal    
DOI: 10.1016/j.gie.2008.05.054     Document Type: Article
Times cited : (22)

References (25)
  • 1
    • 2342472076 scopus 로고    scopus 로고
    • Extended/advanced monitoring techniques in gastrointestinal endoscopy
    • Radaelli F., Terruzzi V., and Minoli G. Extended/advanced monitoring techniques in gastrointestinal endoscopy. Gastrointest Endosc Clin N Am 14 (2004) 335-352
    • (2004) Gastrointest Endosc Clin N Am , vol.14 , pp. 335-352
    • Radaelli, F.1    Terruzzi, V.2    Minoli, G.3
  • 2
    • 13844266196 scopus 로고    scopus 로고
    • Preparation, premedication, and surveillance
    • Lazzaroni M., and Porro G.B. Preparation, premedication, and surveillance. Endoscopy 37 (2005) 101-109
    • (2005) Endoscopy , vol.37 , pp. 101-109
    • Lazzaroni, M.1    Porro, G.B.2
  • 3
    • 0041858036 scopus 로고    scopus 로고
    • Capnographic monitoring of ventilatory status during moderate (conscious) sedation
    • Koniaris L.G., Wilson S., Drugas G., et al. Capnographic monitoring of ventilatory status during moderate (conscious) sedation. Surg Endosc 17 (2003) 1261-1265
    • (2003) Surg Endosc , vol.17 , pp. 1261-1265
    • Koniaris, L.G.1    Wilson, S.2    Drugas, G.3
  • 4
    • 0036615783 scopus 로고    scopus 로고
    • Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy
    • Vargo J.J., Zuccaro Jr. G., Dumot J.A., et al. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc 55 (2002) 826-831
    • (2002) Gastrointest Endosc , vol.55 , pp. 826-831
    • Vargo, J.J.1    Zuccaro Jr., G.2    Dumot, J.A.3
  • 5
    • 0026659889 scopus 로고
    • Guidelines for monitoring and management of pediatric patients during and after sedation for diagnostic and therapeutic procedures
    • American Academy of Pediatrics Committee on Drugs
    • American Academy of Pediatrics Committee on Drugs. Guidelines for monitoring and management of pediatric patients during and after sedation for diagnostic and therapeutic procedures. Pediatrics 89 (1992) 1110-1115
    • (1992) Pediatrics , vol.89 , pp. 1110-1115
  • 6
    • 0033625858 scopus 로고    scopus 로고
    • 2: physiology in pursuit of clinical applications
    • 2: physiology in pursuit of clinical applications. Intensive Care Med 26 (2000) 1595-1597
    • (2000) Intensive Care Med , vol.26 , pp. 1595-1597
    • Levine, R.L.1
  • 7
    • 0035722881 scopus 로고    scopus 로고
    • End-tidal carbon dioxide monitoring in pediatrics: concepts and technology
    • Bhende M.S. End-tidal carbon dioxide monitoring in pediatrics: concepts and technology. J Postgrad Med 47 (2001) 153-156
    • (2001) J Postgrad Med , vol.47 , pp. 153-156
    • Bhende, M.S.1
  • 8
    • 33845788709 scopus 로고    scopus 로고
    • Capnography and depth of sedation during propofol sedation in children
    • Anderson J.L., Junkins E., Pribble C., et al. Capnography and depth of sedation during propofol sedation in children. Ann Emerg Med 49 (2007) 9-13
    • (2007) Ann Emerg Med , vol.49 , pp. 9-13
    • Anderson, J.L.1    Junkins, E.2    Pribble, C.3
  • 9
    • 0029077549 scopus 로고
    • Noninvasive monitoring of end-tidal carbon dioxide tension via nasal cannulas in spontaneously breathing children with profound hypocarbia
    • Flanagan J.F., Garrett J.S., McDuffee A., et al. Noninvasive monitoring of end-tidal carbon dioxide tension via nasal cannulas in spontaneously breathing children with profound hypocarbia. Crit Care Med 23 (1995) 1140-1142
    • (1995) Crit Care Med , vol.23 , pp. 1140-1142
    • Flanagan, J.F.1    Garrett, J.S.2    McDuffee, A.3
  • 10
    • 33745327458 scopus 로고    scopus 로고
    • Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial
    • Lightdale J.R., Goldmann D.A., Feldman H.A., et al. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial. Pediatrics 117 (2006) e1170-e1178
    • (2006) Pediatrics , vol.117
    • Lightdale, J.R.1    Goldmann, D.A.2    Feldman, H.A.3
  • 11
    • 0036204179 scopus 로고    scopus 로고
    • Practice guidelines for sedation and analgesia by non-anesthesiologists
    • Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology 96 (2002) 1004-1017
    • (2002) Anesthesiology , vol.96 , pp. 1004-1017
  • 13
    • 0033238016 scopus 로고    scopus 로고
    • Microstream capnography technology: a new approach to an old problem
    • Colman Y., and Krauss B. Microstream capnography technology: a new approach to an old problem. J Clin Monit Comput 15 (1999) 403-409
    • (1999) J Clin Monit Comput , vol.15 , pp. 403-409
    • Colman, Y.1    Krauss, B.2
  • 14
    • 0035038553 scopus 로고    scopus 로고
    • NPB-75: a portable quantitative Microstream capnometer
    • Singh S., Venkataraman S.T., Saville A., et al. NPB-75: a portable quantitative Microstream capnometer. Am J Emerg Med 19 (2001) 208-210
    • (2001) Am J Emerg Med , vol.19 , pp. 208-210
    • Singh, S.1    Venkataraman, S.T.2    Saville, A.3
  • 15
    • 0033789790 scopus 로고    scopus 로고
    • Accuracy of end-tidal carbon dioxide monitoring using the NBP-75 Microstream capnometer. A study in intubated ventilated and spontaneously breathing nonintubated patients
    • Casati A., Gallioli G., Scandroglio M., et al. Accuracy of end-tidal carbon dioxide monitoring using the NBP-75 Microstream capnometer. A study in intubated ventilated and spontaneously breathing nonintubated patients. Eur J Anaesthesiol 17 (2000) 622-626
    • (2000) Eur J Anaesthesiol , vol.17 , pp. 622-626
    • Casati, A.1    Gallioli, G.2    Scandroglio, M.3
  • 16
    • 25444438012 scopus 로고    scopus 로고
    • Predicting the need for hospitalization in acute childhood asthma using end-tidal capnography
    • Kunkov S., Pinedo V., Silver E.J., et al. Predicting the need for hospitalization in acute childhood asthma using end-tidal capnography. Pediatr Emerg Care 21 (2005) 574-577
    • (2005) Pediatr Emerg Care , vol.21 , pp. 574-577
    • Kunkov, S.1    Pinedo, V.2    Silver, E.J.3
  • 17
    • 19944374453 scopus 로고    scopus 로고
    • End-tidal carbon dioxide monitoring in pediatric emergencies
    • Sullivan K.J., Kissoon N., and Goodwin S.R. End-tidal carbon dioxide monitoring in pediatric emergencies. Pediatr Emerg Care 21 (2005) 327-332
    • (2005) Pediatr Emerg Care , vol.21 , pp. 327-332
    • Sullivan, K.J.1    Kissoon, N.2    Goodwin, S.R.3
  • 18
    • 1642295568 scopus 로고    scopus 로고
    • The value of capnography during sedation or sedation/analgesia in pediatric minor procedures
    • Yldzdas D., Yapcoglu H., and Ylmaz H.L. The value of capnography during sedation or sedation/analgesia in pediatric minor procedures. Pediatr Emerg Care 20 (2004) 162-165
    • (2004) Pediatr Emerg Care , vol.20 , pp. 162-165
    • Yldzdas, D.1    Yapcoglu, H.2    Ylmaz, H.L.3
  • 19
    • 0030877716 scopus 로고    scopus 로고
    • Noninvasive capnometry monitoring for respiratory status during pediatric seizures
    • Abramo T.J., Wiebe R.A., Scott S., et al. Noninvasive capnometry monitoring for respiratory status during pediatric seizures. Crit Care Med 25 (1997) 1242-1246
    • (1997) Crit Care Med , vol.25 , pp. 1242-1246
    • Abramo, T.J.1    Wiebe, R.A.2    Scott, S.3
  • 20
    • 0029795821 scopus 로고    scopus 로고
    • Utility of the expiratory capnogram in the assessment of bronchospasm
    • Yaron M., Padyk P., Hutsinpiller M., et al. Utility of the expiratory capnogram in the assessment of bronchospasm. Ann Emerg Med 28 (1996) 403-407
    • (1996) Ann Emerg Med , vol.28 , pp. 403-407
    • Yaron, M.1    Padyk, P.2    Hutsinpiller, M.3
  • 21
    • 0030871665 scopus 로고    scopus 로고
    • The value of end-tidal CO2 monitoring when comparing three methods of conscious sedation for children undergoing painful procedures in the emergency department
    • Hart L.S., Berns S.D., Houck C.S., et al. The value of end-tidal CO2 monitoring when comparing three methods of conscious sedation for children undergoing painful procedures in the emergency department. Pediatr Emerg Care 13 (1997) 189-193
    • (1997) Pediatr Emerg Care , vol.13 , pp. 189-193
    • Hart, L.S.1    Berns, S.D.2    Houck, C.S.3
  • 22
    • 0033634932 scopus 로고    scopus 로고
    • Capnography during sedation/analgesia in the pediatric emergency department
    • McQuillen K.K., and Steele D.W. Capnography during sedation/analgesia in the pediatric emergency department. Pediatr Emerg Care 16 (2000) 401-404
    • (2000) Pediatr Emerg Care , vol.16 , pp. 401-404
    • McQuillen, K.K.1    Steele, D.W.2
  • 23
    • 0034018773 scopus 로고    scopus 로고
    • A randomized, controlled trial of transcutaneous carbon dioxide monitoring during ERCP
    • Nelson D.B., Freeman M.L., Silvis S.E., et al. A randomized, controlled trial of transcutaneous carbon dioxide monitoring during ERCP. Gastrointest Endosc 51 (2000) 288-295
    • (2000) Gastrointest Endosc , vol.51 , pp. 288-295
    • Nelson, D.B.1    Freeman, M.L.2    Silvis, S.E.3
  • 24
    • 12544256534 scopus 로고    scopus 로고
    • Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip
    • Heuss L.T., Chhajed P.N., Schnieper P., et al. Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip. Digestion 70 (2004) 152-158
    • (2004) Digestion , vol.70 , pp. 152-158
    • Heuss, L.T.1    Chhajed, P.N.2    Schnieper, P.3
  • 25
    • 33846413576 scopus 로고    scopus 로고
    • Complications of pediatric EGD: a 4-year experience in PEDS-CORI
    • Thakkar K., El-Serag H.B., Mattek N., et al. Complications of pediatric EGD: a 4-year experience in PEDS-CORI. Gastrointest Endosc 65 (2007) 213-221
    • (2007) Gastrointest Endosc , vol.65 , pp. 213-221
    • Thakkar, K.1    El-Serag, H.B.2    Mattek, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.