Volumn 15, Issue 6, 1999, Pages 403-409

Microstream capnography technology: A new approach to an old problem

Author keywords

Monitoring: carbon dioxide, molecular correlation spectroscopy, capnography, capnometry, sampling, neonates, infants, human, microstream, filterline

Indexed keywords

CARBON DIOXIDE; OPERATING ROOMS; SPECTROSCOPY;

EID: 0033238016     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1009981115299     Document Type: Article
Times cited : (82)

References (12)
  • 2
    • 0002806682 scopus 로고
    • Capnometry and capnography: The anesthesia disaster early warning system
    • Swedlow DB. Capnometry and capnography: The anesthesia disaster early warning system. Semin Anesth 1986; 3: 194-205
    • (1986) Semin Anesth , vol.3 , pp. 194-205
    • Swedlow, D.B.1
  • 3
    • 0029951342 scopus 로고    scopus 로고
    • Carbon dioxide monitors, exhaled gas
    • Nobel JJ. Carbon dioxide monitors, exhaled gas. Pediatr Emerg Care 1996; 12: 239-240
    • (1996) Pediatr Emerg Care , vol.12 , pp. 239-240
    • Nobel, J.J.1
  • 5
    • 0023160209 scopus 로고
    • 2 monitoring in infants and children ventilated with either a partial rebreathing or a non-rebreathing circuit
    • 2 monitoring in infants and children ventilated with either a partial rebreathing or a non-rebreathing circuit. Anesthesiology 1987; 66: 405-410
    • (1987) Anesthesiology , vol.66 , pp. 405-410
    • Badgwell, J.M.1    Heavner, J.E.2    May, W.S.3
  • 7
    • 0025278967 scopus 로고
    • Capnometry and capnography: Technical aspects, physiologic aspects, and clinical applications
    • Hess D. Capnometry and capnography: Technical aspects, physiologic aspects, and clinical applications. Respir Care 1990; 35: 557-573
    • (1990) Respir Care , vol.35 , pp. 557-573
    • Hess, D.1
  • 8
    • 0026187760 scopus 로고
    • Technical and clinical aspects of capnography in neonates
    • Kirpalani H, Kechagias S, Lerman J. Technical and clinical aspects of capnography in neonates. J Med Eng Tech 1991; 15: 154-161
    • (1991) J Med Eng Tech , vol.15 , pp. 154-161
    • Kirpalani, H.1    Kechagias, S.2    Lerman, J.3
  • 9
    • 0024537780 scopus 로고
    • Capnometry in infants should not be done at lower sampling flow rates
    • Gravenstein N. Capnometry in infants should not be done at lower sampling flow rates. J Clin Monit 1989; 5: 63-64
    • (1989) J Clin Monit , vol.5 , pp. 63-64
    • Gravenstein, N.1
  • 10
    • 0022096079 scopus 로고
    • Can we trust end-tidal carbon dioxide measurements in infants?
    • Sasse FJ. Can we trust end-tidal carbon dioxide measurements in infants?J Clin Monit 1985; 1: 147-148
    • (1985) J Clin Monit , vol.1 , pp. 147-148
    • Sasse, F.J.1
  • 11
  • 12
    • 0021881488 scopus 로고
    • Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects
    • Schieber RA, Namnoum A, Sugden A et al. Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects. J Clin Monit 1985; 1: 149-155
    • (1985) J Clin Monit , vol.1 , pp. 149-155
    • Schieber, R.A.1    Namnoum, A.2    Sugden, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.