메뉴 건너뛰기




Volumn 32, Issue 3, 2009, Pages 353-359

Conductometric immunoassay for interleukin-6 in human serum based on organic/inorganic hybrid membrane-functionalized interface

Author keywords

Conductometric immunosensor; Gold nanoparticles; Interleukin 6; Organic inorganic hybrid film

Indexed keywords

ALMOST CONSISTENT; ANTIGEN-ANTIBODY INTERACTIONS; BEFORE AND AFTER; COLLOIDAL ALUMINAS; CONDUCTOMETRIC IMMUNOSENSOR; DETECTION SENSITIVITIES; DETECTION SIGNALS; ENZYME LINKED IMMUNO-SORBENT ASSAYS; FUNCTIONALIZED; GOLD NANOPARTICLES; HORSE-RADISH PEROXIDASE; HUMAN SERUM; INTERLEUKIN 6; LOW DETECTION LIMITS; MICROENVIRONMENT; NANO GOLDS; NANOGOLD PARTICLES; OPTIMAL CONDITIONS; ORGANIC/INORGANIC HYBRID FILM; ORGANIC/INORGANIC HYBRIDS; PHOSPHATE BUFFER SOLUTIONS; REPRODUCIBILITY; SURFACE COVERAGES; WIDE-LINEAR RANGES;

EID: 62949088126     PISSN: 16157591     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00449-008-0254-0     Document Type: Article
Times cited : (20)

References (19)
  • 1
    • 43049096082 scopus 로고    scopus 로고
    • Bmx regulates LPS-induced IL-6 and VEGF production via mRNA stability in rheumatoid synovial fibroblasts
    • CD Palmer BE Mutch TH Page NJ Horwood BMJ Foxwell 2008 Bmx regulates LPS-induced IL-6 and VEGF production via mRNA stability in rheumatoid synovial fibroblasts Biochem Biophys Res Commun 370 599 602
    • (2008) Biochem Biophys Res Commun , vol.370 , pp. 599-602
    • Palmer, C.D.1    Mutch, B.E.2    Page, T.H.3    Horwood, N.J.4    Foxwell, B.M.J.5
  • 3
    • 43949140522 scopus 로고    scopus 로고
    • Microfluidic capillary system for immunoaffinity separations of C-reactive protein in human serum and cereborospinal fluid
    • MC Peoples HT Karnes 2008 Microfluidic capillary system for immunoaffinity separations of C-reactive protein in human serum and cereborospinal fluid Anal Chem 50 3852 3858
    • (2008) Anal Chem , vol.50 , pp. 3852-3858
    • Peoples, M.C.1    Karnes, H.T.2
  • 4
    • 34447651129 scopus 로고    scopus 로고
    • Direct and rapid monitoring the biochemical reaction of interleukin-6 in human using a flow-injection capactive immunosensor in clinical immunoassay
    • J Pan 2007 Direct and rapid monitoring the biochemical reaction of interleukin-6 in human using a flow-injection capactive immunosensor in clinical immunoassay Sens Actuators B 125 517 525
    • (2007) Sens Actuators B , vol.125 , pp. 517-525
    • Pan, J.1
  • 5
    • 33846310718 scopus 로고    scopus 로고
    • Development of a gold nanoparticles based chemiluminescence imaging assay and its application
    • LR Luo ZJ Zhang LY Hou 2007 Development of a gold nanoparticles based chemiluminescence imaging assay and its application Anal Chim Acta 584 106 111
    • (2007) Anal Chim Acta , vol.584 , pp. 106-111
    • Luo, L.R.1    Zhang, Z.J.2    Hou, L.Y.3
  • 7
    • 33750373606 scopus 로고    scopus 로고
    • Flow-injection immuno-bioassay for interleukin-6 in humans based on gold nanoparticles modified screen-printed graphite electrodes
    • KZ Liang WJ Mu 2006 Flow-injection immuno-bioassay for interleukin-6 in humans based on gold nanoparticles modified screen-printed graphite electrodes Anal Chim Acta 580 128 135
    • (2006) Anal Chim Acta , vol.580 , pp. 128-135
    • Liang, K.Z.1    Mu, W.J.2
  • 8
    • 44049088089 scopus 로고    scopus 로고
    • Comductometric immunosensors for the detection of staphylococcal enterotoxin B based bio-electrocalytic reaction on micro-comb electrodes
    • ZG Chen 2008 Comductometric immunosensors for the detection of staphylococcal enterotoxin B based bio-electrocalytic reaction on micro-comb electrodes Bioproc Biosyst Eng 31 345 350
    • (2008) Bioproc Biosyst Eng , vol.31 , pp. 345-350
    • Chen, Z.G.1
  • 9
    • 33845983618 scopus 로고    scopus 로고
    • Electrochemical biosensing with nanoparticles
    • A Merkoci 2007 Electrochemical biosensing with nanoparticles FEBS J 274 310 316
    • (2007) FEBS J , vol.274 , pp. 310-316
    • Merkoci, A.1
  • 11
    • 41549123570 scopus 로고    scopus 로고
    • Detecting organic vapors using a conductometric sensor prepared from Ardel((R))D-100 and graphite
    • O Yazici MR Moroglu H Cankurtaran O Cankurtaran F Karaman 2008 Detecting organic vapors using a conductometric sensor prepared from Ardel((R))D-100 and graphite Microchim Acta 160 441 445
    • (2008) Microchim Acta , vol.160 , pp. 441-445
    • Yazici, O.1    Moroglu, M.R.2    Cankurtaran, H.3    Cankurtaran, O.4    Karaman, F.5
  • 12
    • 38349125612 scopus 로고    scopus 로고
    • Advances in amperometric and conductometric detection in capillary and chip-based electrophoresis
    • FM Matysik 2008 Advances in amperometric and conductometric detection in capillary and chip-based electrophoresis Microchim Acta 160 1 14
    • (2008) Microchim Acta , vol.160 , pp. 1-14
    • Matysik, F.M.1
  • 13
    • 33747214984 scopus 로고    scopus 로고
    • Interdigitated conductometric immunosensor for determination of interleukin-6 in humans based on dendrimer G4 and colloidal gold modified composite film
    • KZ Liang WJ Mu MY Huang QK Lai 2006 Interdigitated conductometric immunosensor for determination of interleukin-6 in humans based on dendrimer G4 and colloidal gold modified composite film Electroanalysis 18 1505 1510
    • (2006) Electroanalysis , vol.18 , pp. 1505-1510
    • Liang, K.Z.1    Mu, W.J.2    Huang, M.Y.3    Lai, Q.K.4
  • 14
    • 12444330291 scopus 로고    scopus 로고
    • Biosensors in clinical chemistry
    • P D'Orazio 2003 Biosensors in clinical chemistry Clin Chim Acta 334 41 69
    • (2003) Clin Chim Acta , vol.334 , pp. 41-69
    • D'Orazio, P.1
  • 16
    • 54549125719 scopus 로고    scopus 로고
    • Biomolecule-doped organic/inorganic hybrid nanocomposite film for label-free electrochemical immunoassay of fetoprein
    • CL Hong R Yuan YQ Chai Y Zhuo 2008 Biomolecule-doped organic/inorganic hybrid nanocomposite film for label-free electrochemical immunoassay of fetoprein Electroanalysis 20 989 995
    • (2008) Electroanalysis , vol.20 , pp. 989-995
    • Hong, C.L.1    Yuan, R.2    Chai, Y.Q.3    Zhuo, Y.4
  • 17
    • 34547659018 scopus 로고    scopus 로고
    • Optical and photovoltaic properties of thin films of N, N′-dimethyl-3, 4A 10-perylenetetracarboxylic acid diimide
    • Y Vertsimakha P Lutsyk K Palewska J Sworakowski O Lytvyn 2007 Optical and photovoltaic properties of thin films of N, N′-dimethyl-3, 4A 10-perylenetetracarboxylic acid diimide Thin Solid Films 515 7950 7957
    • (2007) Thin Solid Films , vol.515 , pp. 7950-7957
    • Vertsimakha, Y.1    Lutsyk, P.2    Palewska, K.3    Sworakowski, J.4    Lytvyn, O.5
  • 18
    • 41149152357 scopus 로고    scopus 로고
    • Ultrasensitive electrochemical immunosensor for clinical immunoassay using thionine-doped magnetic gold nanospheres as labels and horseradish peroxidase as enhancer
    • DP Tang R Yuan Y Chai 2008 Ultrasensitive electrochemical immunosensor for clinical immunoassay using thionine-doped magnetic gold nanospheres as labels and horseradish peroxidase as enhancer Anal Chem 80 1582 1588
    • (2008) Anal Chem , vol.80 , pp. 1582-1588
    • Tang, D.P.1    Yuan, R.2    Chai, Y.3
  • 19
    • 0034302792 scopus 로고    scopus 로고
    • Probing trace phenols based on mediator-free alumina sol-gel-derived tyrosinase biosensor
    • Z Liu B Liu J Kong J Deng 2000 Probing trace phenols based on mediator-free alumina sol-gel-derived tyrosinase biosensor Anal Chem 72 4707 4712
    • (2000) Anal Chem , vol.72 , pp. 4707-4712
    • Liu, Z.1    Liu, B.2    Kong, J.3    Deng, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.