메뉴 건너뛰기




Volumn 137, Issue 2, 2009, Pages 524-528

Sensing performance of thermoelectric hydrogen sensor for breath hydrogen analysis

Author keywords

Gas sensor; Human breath; Hydrogen; Thermoelectric device

Indexed keywords

CARBON MONOXIDE; CHEMICAL SENSORS; GAS DETECTORS; GASES; GELATION; HYDROGEN; METHANE; MOISTURE; SILICA; SILICA GEL;

EID: 62649135138     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.01.029     Document Type: Article
Times cited : (47)

References (11)
  • 3
    • 0031933897 scopus 로고    scopus 로고
    • Breath hydrogen and methane expiration in men and women after oat extract consumption
    • Behall K.M., Scholfield D.J., van der Sluijs A.M.C., and Hallfrisch J. Breath hydrogen and methane expiration in men and women after oat extract consumption. J. Nutr. 128 (1998) 79-84
    • (1998) J. Nutr. , vol.128 , pp. 79-84
    • Behall, K.M.1    Scholfield, D.J.2    van der Sluijs, A.M.C.3    Hallfrisch, J.4
  • 4
    • 0346655085 scopus 로고    scopus 로고
    • Evaluation of the pulsed discharge helium ionization detector for the analysis of hydrogen and methane in breath
    • Roberge M.T., Finley J.W., Lukaski H.C., and Borberding A.J. Evaluation of the pulsed discharge helium ionization detector for the analysis of hydrogen and methane in breath. J. Chromatogr. A 1027 (2004) 19-23
    • (2004) J. Chromatogr. A , vol.1027 , pp. 19-23
    • Roberge, M.T.1    Finley, J.W.2    Lukaski, H.C.3    Borberding, A.J.4
  • 5
    • 48349134310 scopus 로고    scopus 로고
    • Evaluation of colonic flora by measuring breath hydrogen and nitrous oxide
    • (in Japanese)
    • Ishiguro H., Mitsui T., Fujiki R., Naruse T., and Kondo T. Evaluation of colonic flora by measuring breath hydrogen and nitrous oxide. Shokaki-ka 39 (2004) 144-148 (in Japanese)
    • (2004) Shokaki-ka , vol.39 , pp. 144-148
    • Ishiguro, H.1    Mitsui, T.2    Fujiki, R.3    Naruse, T.4    Kondo, T.5
  • 6
    • 33746216893 scopus 로고    scopus 로고
    • From highly sophisticated analytical techniques to life-saving diagnostics: technical developments in breath analysis
    • Miekisch W., and Schubert J.K. From highly sophisticated analytical techniques to life-saving diagnostics: technical developments in breath analysis. TrAC-Trends Anal. Chem. 25 (2006) 665-672
    • (2006) TrAC-Trends Anal. Chem. , vol.25 , pp. 665-672
    • Miekisch, W.1    Schubert, J.K.2
  • 9
    • 19744362289 scopus 로고    scopus 로고
    • Effect of humidity on the sensing property of thermoelectric hydrogen sensor
    • Sawaguchi N., Shin W., Izu N., Matsubara I., and Murayama N. Effect of humidity on the sensing property of thermoelectric hydrogen sensor. Sens. Actuators, B 108 (2005) 461-466
    • (2005) Sens. Actuators, B , vol.108 , pp. 461-466
    • Sawaguchi, N.1    Shin, W.2    Izu, N.3    Matsubara, I.4    Murayama, N.5
  • 10
    • 33646750597 scopus 로고    scopus 로고
    • Effect of Pt/alumina catalyst preparation method on sensing performance of thermoelectric hydrogen sensor
    • Choi Y., Tajima K., Shin W., Izu N., Matsubara I., and Murayama N. Effect of Pt/alumina catalyst preparation method on sensing performance of thermoelectric hydrogen sensor. J. Mater. Sci. 41 (2006) 2333-2338
    • (2006) J. Mater. Sci. , vol.41 , pp. 2333-2338
    • Choi, Y.1    Tajima, K.2    Shin, W.3    Izu, N.4    Matsubara, I.5    Murayama, N.6
  • 11
    • 0026581702 scopus 로고
    • Guar, but not psyllium, increases breath methane and serum acetate concentrations in human subjects
    • Wolever T.M.S., Wal P.t., Spadafora P., and Robb P. Guar, but not psyllium, increases breath methane and serum acetate concentrations in human subjects. Am. J. Clin. Nutr. 55 (1992) 719-722
    • (1992) Am. J. Clin. Nutr. , vol.55 , pp. 719-722
    • Wolever, T.M.S.1    Wal, P.t.2    Spadafora, P.3    Robb, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.