메뉴 건너뛰기




Volumn 179, Issue , 2009, Pages 169-182

Computer-assisted pelvic tumor resection: Fields of application, limits, and perspectives

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMICAL VARIATION; CANCER SURGERY; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OUTCOME ASSESSMENT; PELVIS OSTEOTOMY; PELVIS TUMOR; PEROPERATIVE CARE; PREOPERATIVE EVALUATION; PRESERVATION; PRIORITY JOURNAL; REGISTRATION; REPRODUCTION; REVIEW; THREE DIMENSIONAL IMAGING;

EID: 62249117776     PISSN: 00800015     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-3-540-77960-5_11     Document Type: Review
Times cited : (26)

References (60)
  • 2
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar and sacral spine
    • Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar and sacral spine. Spine 25:606-614
    • (2000) Spine , vol.25 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3    Zippel, H.4    Labelle, H.5
  • 5
    • 0037318534 scopus 로고    scopus 로고
    • Multimodal therapy for the treatment of nonmetastatic Ewing's sarcoma ofpelvis
    • BacciG, FerrariS, Mercuri M, et al.: Multimodal therapy for the treatment of nonmetastatic Ewing's sarcoma ofpelvis. J Pediatr Hematol Oncol 2003; 25:118-124.
    • (2003) J Pediatr Hematol Oncol , vol.25 , pp. 118-124
    • Bacci, G.1    Ferrari, S.2    Mercuri, M.3
  • 6
    • 0035197536 scopus 로고    scopus 로고
    • Restricted surface matching: Numerical optimization and technical evaluation
    • Bächler R, Bunke H, Nolte LP (2001) Restricted surface matching: numerical optimization and technical evaluation. Comput Aided Surg 6:143-152
    • (2001) Comput Aided Surg , vol.6 , pp. 143-152
    • Bächler, R.1    Bunke, H.2    Nolte, L.P.3
  • 8
    • 77953663586 scopus 로고    scopus 로고
    • Bowersox JC, Bucholz RD, Delp SL (1997) Excerpts from the final report for the Second International Workshop on Robotics and Computer Assisted Medical Interventions. Comput Aided Surg 2:69-101
    • Bowersox JC, Bucholz RD, Delp SL (1997) Excerpts from the final report for the Second International Workshop on Robotics and Computer Assisted Medical Interventions. Comput Aided Surg 2:69-101
  • 9
    • 0026098587 scopus 로고
    • Pelvic resections: The Rizzoli Institute experience
    • Campanacci M, Capanna R (1991) Pelvic resections: the Rizzoli Institute experience. Orthop Clin North Am 22:65-86
    • (1991) Orthop Clin North Am , vol.22 , pp. 65-86
    • Campanacci, M.1    Capanna, R.2
  • 11
    • 40749153525 scopus 로고    scopus 로고
    • Development and validation of a three dimensional ultrasound based navigation system for tumor resection
    • Chopra SS, Hünerbein M, Eulenstein S, Lange T, Schlag PM, Beller S (2007) Development and validation of a three dimensional ultrasound based navigation system for tumor resection. Eur J Surg Oncol 34:456-461
    • (2007) Eur J Surg Oncol , vol.34 , pp. 456-461
    • Chopra, S.S.1    Hünerbein, M.2    Eulenstein, S.3    Lange, T.4    Schlag, P.M.5    Beller, S.6
  • 14
    • 0011721103 scopus 로고
    • Local resection of malignant lesions of the hip and pelvis
    • Enneking WF (1966) Local resection of malignant lesions of the hip and pelvis. J Bone Joint Surg Am 48:991-1007
    • (1966) J Bone Joint Surg Am , vol.48 , pp. 991-1007
    • Enneking, W.F.1
  • 15
    • 0018166253 scopus 로고
    • Resection and reconstruction for primary neoplasms involving the innominate bone
    • Enneking WF, Dunham WK (1978) Resection and reconstruction for primary neoplasms involving the innominate bone. J Bone Joint Surg 60A:731-746
    • (1978) J Bone Joint Surg , vol.60 A , pp. 731-746
    • Enneking, W.F.1    Dunham, W.K.2
  • 17
    • 32944466741 scopus 로고    scopus 로고
    • Navigationsgestützte Resektion maligner Knochentumoren des Beckens.
    • Fehlberg S, Lange T, Eulenstein S, Schlag PM, Tunn PU (2006) Navigationsgestützte Resektion maligner Knochentumoren des Beckens. Onkologe 12:152-157
    • (2006) Onkologe , vol.12 , pp. 152-157
    • Fehlberg, S.1    Lange, T.2    Eulenstein, S.3    Schlag, P.M.4    Tunn, P.U.5
  • 20
    • 0035725847 scopus 로고    scopus 로고
    • A surface matching technique for robot-assisted registration
    • Glozman D, Shoham M, Fischer A (2001) A surface matching technique for robot-assisted registration. Comput Aided Surg 6:259-269
    • (2001) Comput Aided Surg , vol.6 , pp. 259-269
    • Glozman, D.1    Shoham, M.2    Fischer, A.3
  • 21
    • 33644929205 scopus 로고    scopus 로고
    • Functional results and quality of life after treatment of pelvic sarcomas involving the acetabulum
    • Hoffmann C, Gosheger G, Gebert C, Jürgens H, Winkelmann W (2006) Functional results and quality of life after treatment of pelvic sarcomas involving the acetabulum. J Bone Joint Surg Am 88:575-582
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 575-582
    • Hoffmann, C.1    Gosheger, G.2    Gebert, C.3    Jürgens, H.4    Winkelmann, W.5
  • 23
    • 0032415763 scopus 로고    scopus 로고
    • Optical high-precision threedimensional position measurement system suitable for head motion tracking in frameless stereotactic radiosurgery
    • Kai J, Shiomi H, Sasama T, Sato Y, Inoue T, Tamura S, Inoue T (1998) Optical high-precision threedimensional position measurement system suitable for head motion tracking in frameless stereotactic radiosurgery. Comput Aided Surg 3:257-263
    • (1998) Comput Aided Surg , vol.3 , pp. 257-263
    • Kai, J.1    Shiomi, H.2    Sasama, T.3    Sato, Y.4    Inoue, T.5    Tamura, S.6    Inoue, T.7
  • 28
    • 2942567909 scopus 로고    scopus 로고
    • Computer aided tumor resection in the pelvis
    • Krettek C, Geerling J, Bastian L (2004) Computer aided tumor resection in the pelvis. Injury 35[Suppl 1]:SA79-83
    • (2004) Injury , vol.35 , Issue.SUPPL. 1
    • Krettek, C.1    Geerling, J.2    Bastian, L.3
  • 29
    • 0031412924 scopus 로고    scopus 로고
    • The first twelve cases of computer assisted periacetabular osteotomy
    • Langlotz F, Stucki M, Bächler R (1997) The first twelve cases of computer assisted periacetabular osteotomy. Comput Aided Surg 2:317-326
    • (1997) Comput Aided Surg , vol.2 , pp. 317-326
    • Langlotz, F.1    Stucki, M.2    Bächler, R.3
  • 32
    • 0023381475 scopus 로고
    • Marching cubes: A high resolution 3D surface construction algorithm
    • Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. Proc ACM SIGGRAPH 21:163-169
    • (1987) Proc ACM SIGGRAPH , vol.21 , pp. 163-169
    • Lorensen, W.E.1    Cline, H.E.2
  • 33
    • 4444239130 scopus 로고    scopus 로고
    • Automated laser registration in image-guided surgery: Evaluation of the correlation between laser scan resolution and navigation accuracy
    • Marmulla R, Lüth T, Mühling J, Hassfeld S (2004) Automated laser registration in image-guided surgery: evaluation of the correlation between laser scan resolution and navigation accuracy. Int J Oral Maxillofac Surg 33:642-648
    • (2004) Int J Oral Maxillofac Surg , vol.33 , pp. 642-648
    • Marmulla, R.1    Lüth, T.2    Mühling, J.3    Hassfeld, S.4
  • 35
    • 11844295948 scopus 로고    scopus 로고
    • The use of computerized navigation in the treatment of gun shot and shrapnel injury
    • Mosheiff R, Weil Y, Khoury A, Liebergall M (2004) The use of computerized navigation in the treatment of gun shot and shrapnel injury. Comput Aided Surg 9:39-43
    • (2004) Comput Aided Surg , vol.9 , pp. 39-43
    • Mosheiff, R.1    Weil, Y.2    Khoury, A.3    Liebergall, M.4
  • 36
    • 0026055122 scopus 로고
    • Three-dimensional volumetric display of CT data: Effect of scan parameters upon image quality
    • Ney DR, Fishman EK, Magid D, Robertson DD, Kawashima A (1991) Three-dimensional volumetric display of CT data: effect of scan parameters upon image quality. J Comput Assist Tomogr 15:875-885
    • (1991) J Comput Assist Tomogr , vol.15 , pp. 875-885
    • Ney, D.R.1    Fishman, E.K.2    Magid, D.3    Robertson, D.D.4    Kawashima, A.5
  • 37
    • 2942585202 scopus 로고    scopus 로고
    • Basic principles of CAOS
    • Nolte L, Beutler T (2004) Basic principles of CAOS. Injury 35[Suppl 1]:SA6-A16
    • (2004) Injury , vol.35 , Issue.SUPPL. 1
    • Nolte, L.1    Beutler, T.2
  • 41
    • 0017752663 scopus 로고
    • Incidence of bone sarcoma in SW England, 1946-1974, in relation to age, sex, tumour site and histology
    • Price CH, Jeffree GM (1977) Incidence of bone sarcoma in SW England, 1946-1974, in relation to age, sex, tumour site and histology. Br J Cancer 36:511-522
    • (1977) Br J Cancer , vol.36 , pp. 511-522
    • Price, C.H.1    Jeffree, G.M.2
  • 42
    • 0035186460 scopus 로고    scopus 로고
    • Chondrosarcoma of the pelvis: A review of sixtyfour cases
    • Pring ME, Weber KL, Unni K, Sim FH (2001) Chondrosarcoma of the pelvis: a review of sixtyfour cases. J Bone Joint Surg 83A:1630-1642
    • (2001) J Bone Joint Surg , vol.83 A , pp. 1630-1642
    • Pring, M.E.1    Weber, K.L.2    Unni, K.3    Sim, F.H.4
  • 43
    • 0033646772 scopus 로고    scopus 로고
    • Use of internal fiducial markers in frameless stereotactic navigational systems during spinal surgery: Technical note
    • Salehi SA, Ondra SL (2000) Use of internal fiducial markers in frameless stereotactic navigational systems during spinal surgery: technical note. Neurosurgery 47:1460-1462
    • (2000) Neurosurgery , vol.47 , pp. 1460-1462
    • Salehi, S.A.1    Ondra, S.L.2
  • 45
    • 0031829684 scopus 로고    scopus 로고
    • Image processing and spiral CT of the thorax
    • Richenberg JL, Hansell DM (1998) Image processing and spiral CT of the thorax. Brit J Radiol 71:708-716
    • (1998) Brit J Radiol , vol.71 , pp. 708-716
    • Richenberg, J.L.1    Hansell, D.M.2
  • 47
    • 1842584485 scopus 로고    scopus 로고
    • Image fusion of MR images and real-time ultrasonography: Evaluation of fusion accuracy combining two commercial instruments, a neuronavigation system and a ultrasound system
    • Schlaier JR, Warnat J, Dorenbeck U, Proescholdt M, Schebesch KM, Brawanski A (2004) Image fusion of MR images and real-time ultrasonography: evaluation of fusion accuracy combining two commercial instruments, a neuronavigation system and a ultrasound system. Acta Neurochir (Wien) 146:271-277
    • (2004) Acta Neurochir (Wien) , vol.146 , pp. 271-277
    • Schlaier, J.R.1    Warnat, J.2    Dorenbeck, U.3    Proescholdt, M.4    Schebesch, K.M.5    Brawanski, A.6
  • 48
    • 0032459477 scopus 로고    scopus 로고
    • Computer assisted surgery: Historical remarks
    • Schlöndorff G (1998) Computer assisted surgery: historical remarks. Comput Aided Surg 3:150-152
    • (1998) Comput Aided Surg , vol.3 , pp. 150-152
    • Schlöndorff, G.1
  • 49
    • 0031686277 scopus 로고    scopus 로고
    • Medical imaging and registration in computer-assisted surgery
    • Simon DA, Lavallée S (1998) Medical imaging and registration in computer-assisted surgery. Clin Orthop Relat Res 354:17-27
    • (1998) Clin Orthop Relat Res , vol.354 , pp. 17-27
    • Simon, D.A.1    Lavallée, S.2
  • 50
    • 0027493601 scopus 로고
    • Spinal pedicle fixation: Confirmation of an image-based technique for screw placement
    • Steinmann JC, Herkowitz HN, El-Kommos H, Wesolowsko DP (1993) Spinal pedicle fixation: confirmation of an image-based technique for screw placement. Spine 18:1856-1861
    • (1993) Spine , vol.18 , pp. 1856-1861
    • Steinmann, J.C.1    Herkowitz, H.N.2    El-Kommos, H.3    Wesolowsko, D.P.4
  • 52
    • 0035708295 scopus 로고    scopus 로고
    • Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach
    • Sugano N, Sasama T, Sato Y, Nakajima Y, Nishii T, Yonenobu K, Tamura S, Ochi T (2001) Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach. Comput Aided Surg 6:195-203
    • (2001) Comput Aided Surg , vol.6 , pp. 195-203
    • Sugano, N.1    Sasama, T.2    Sato, Y.3    Nakajima, Y.4    Nishii, T.5    Yonenobu, K.6    Tamura, S.7    Ochi, T.8
  • 53
    • 0344013618 scopus 로고    scopus 로고
    • Ablative Verfahren bei der operativen Behandlung maligner Knochentumoren.
    • Tunn PU, Delbrück H, Schlag PM (2003) Ablative Verfahren bei der operativen Behandlung maligner Knochentumoren. Orthopäde 32:955-964
    • (2003) Orthopäde , vol.32 , pp. 955-964
    • Tunn, P.U.1    Delbrück, H.2    Schlag, P.M.3
  • 55
    • 0034868757 scopus 로고    scopus 로고
    • Surgical treatment of pelvic sarcomas: Oncologic and functional outcome
    • Wirbel RJ, Schulte M, Mutschler WE (2001) Surgical treatment of pelvic sarcomas: oncologic and functional outcome. Clin Orthop Relat Res 190-205
    • (2001) Clin Orthop Relat Res , pp. 190-205
    • Wirbel, R.J.1    Schulte, M.2    Mutschler, W.E.3
  • 58
    • 34548417568 scopus 로고    scopus 로고
    • Computer assisted pelvic tumor resection and reconstruction with a custom-made prosthesis using an innovative adaptation and its validation
    • Wong KC, Kumta SM, Chiu KH, Cheung KW, Leung KS, Unwin P, Wong MC (2007b) Computer assisted pelvic tumor resection and reconstruction with a custom-made prosthesis using an innovative adaptation and its validation. Comput Aided Surg 12:225-232
    • (2007) Comput Aided Surg , vol.12 , pp. 225-232
    • Wong, K.C.1    Kumta, S.M.2    Chiu, K.H.3    Cheung, K.W.4    Leung, K.S.5    Unwin, P.6    Wong, M.C.7
  • 60
    • 34249934190 scopus 로고    scopus 로고
    • Disease-and recurrence-free survival after surgical resection of solitary bone metastases of the pelvis
    • Yasko A, Rutledge J, Lewis VO, Lin PP (2007) Disease-and recurrence-free survival after surgical resection of solitary bone metastases of the pelvis. Clin Orthop Relat Res 459:128-132
    • (2007) Clin Orthop Relat Res , vol.459 , pp. 128-132
    • Yasko, A.1    Rutledge, J.2    Lewis, V.O.3    Lin, P.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.