메뉴 건너뛰기




Volumn 33, Issue 1, 2009, Pages 26-31

Technical note: Raw data-based approach to identify the optimal reconstruction phase in coronary computed tomography angiography

Author keywords

Cardiac imaging; Kymogram; Optimal reconstruction phase; Spiral CT

Indexed keywords

ANGIOGRAPHY; COMPUTERIZED TOMOGRAPHY; HEART; HOSPITAL DATA PROCESSING; IMAGE ENHANCEMENT; IMAGE QUALITY; ITERATIVE METHODS;

EID: 62149135347     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/RCT.0b013e31816c5c33     Document Type: Article
Times cited : (2)

References (32)
  • 1
    • 0032414773 scopus 로고    scopus 로고
    • Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • Kachelrieß M, Kalender WA. Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys. 1998;25:2417-2431.
    • (1998) Med Phys , vol.25 , pp. 2417-2431
    • Kachelrieß, M.1    Kalender, W.A.2
  • 2
    • 0033863629 scopus 로고    scopus 로고
    • ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    • Kachelrieß M, Ulzheimer S, Kalender WA. ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med Phys. 2000;27:1881-1902.
    • (2000) Med Phys , vol.27 , pp. 1881-1902
    • Kachelrieß, M.1    Ulzheimer, S.2    Kalender, W.A.3
  • 3
    • 0034117652 scopus 로고    scopus 로고
    • High temporal resolution for multislice helical computed tomography
    • Taguchi K, Anno H. High temporal resolution for multislice helical computed tomography. Med Phys. 2000;27:861-872.
    • (2000) Med Phys , vol.27 , pp. 861-872
    • Taguchi, K.1    Anno, H.2
  • 4
    • 0036596445 scopus 로고    scopus 로고
    • A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage
    • Flohr T, Prokop M, Becker C, et al. A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage. Eur Radiol. 2002;12:1497-1503.
    • (2002) Eur Radiol , vol.12 , pp. 1497-1503
    • Flohr, T.1    Prokop, M.2    Becker, C.3
  • 5
    • 66149165432 scopus 로고    scopus 로고
    • Willi A. Kalender WA, Kachelrieß M. Computertomograph mit objektbezogener Bewegungsartefaktreduktion und Extraktion der Objektbewegungsinformation Kymogramm, European Patent Office 1999. Patent pending. Patent no, 99111708.6-1522
    • Willi A. Kalender WA, Kachelrieß M. Computertomograph mit objektbezogener Bewegungsartefaktreduktion und Extraktion der Objektbewegungsinformation (Kymogramm). European Patent Office 1999. Patent pending. Patent no.: 99111708.6-1522.
  • 6
    • 0035996436 scopus 로고    scopus 로고
    • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • KachelrieQ M, Sennst DA, Maxlmoser W, et al. Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys.2002;29: 1489-1503.
    • (2002) Med Phys , vol.29 , pp. 1489-1503
    • KachelrieQ, M.1    Sennst, D.A.2    Maxlmoser, W.3
  • 7
    • 0041738095 scopus 로고    scopus 로고
    • Cardiac spiral imaging in computed tomography without ECG using complementary projections for motion detection
    • Bruder H, Maguet E, Stierstorfer K, et al. Cardiac spiral imaging in computed tomography without ECG using complementary projections for motion detection. Proc SPIE. 2003;5032:1798-1809.
    • (2003) Proc SPIE , vol.5032 , pp. 1798-1809
    • Bruder, H.1    Maguet, E.2    Stierstorfer, K.3
  • 8
    • 39149106467 scopus 로고    scopus 로고
    • Validation of a rawdata-based synchronization signal (kymogram) for a phase-correlated cardiac image reconstruction
    • Ertel D, Pflederer T, Achenbach S, et al. Validation of a rawdata-based synchronization signal (kymogram) for a phase-correlated cardiac image reconstruction. Eur Radiol. 2008;18(2):253-262.
    • (2008) Eur Radiol , vol.18 , Issue.2 , pp. 253-262
    • Ertel, D.1    Pflederer, T.2    Achenbach, S.3
  • 9
    • 66149168237 scopus 로고    scopus 로고
    • Ertel D. Kymogram-based cardiac CT image reconstruction. In: Berichte aus dem Institutfur Medizinische Physik. Bd. 16 (Hrsg.: W. A. Kalender), Shaker Verlag Aachen; 2007. ISBN 978-3-8322-6273-0.
    • Ertel D. Kymogram-based cardiac CT image reconstruction. In: Berichte aus dem Institutfur Medizinische Physik. Bd. 16 (Hrsg.: W. A. Kalender), Shaker Verlag Aachen; 2007. ISBN 978-3-8322-6273-0.
  • 10
    • 0033876932 scopus 로고    scopus 로고
    • In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    • Achenbach S, Ropers D, Holle J, et al. In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology. 2000;216:457-463.
    • (2000) Radiology , vol.216 , pp. 457-463
    • Achenbach, S.1    Ropers, D.2    Holle, J.3
  • 11
    • 33746899303 scopus 로고    scopus 로고
    • Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT
    • Leschka S, Husmann L, Desbiolles LM, et al. Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT. Eur Radiol. 2006;16:1962-1972.
    • (2006) Eur Radiol , vol.16 , pp. 1962-1972
    • Leschka, S.1    Husmann, L.2    Desbiolles, L.M.3
  • 12
    • 0032719272 scopus 로고    scopus 로고
    • Cardiac motion of coronary arteries: Variability in the rest period and implications for coronary MR angiography
    • Wang Y, Vidan E, Bergmann GW. Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology. 1999;213:751-758.
    • (1999) Radiology , vol.213 , pp. 751-758
    • Wang, Y.1    Vidan, E.2    Bergmann, G.W.3
  • 13
    • 29344476149 scopus 로고    scopus 로고
    • Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality
    • Herzog C, Arning-Erb M, Zangos S, et al. Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology. 2006;238:75-86.
    • (2006) Radiology , vol.238 , pp. 75-86
    • Herzog, C.1    Arning-Erb, M.2    Zangos, S.3
  • 14
    • 35348974041 scopus 로고    scopus 로고
    • Coronary artery motion and cardiac phases: Dependency on heart rate - implications for CT image reconstruction
    • Husmann L, Leschka S, Desbiolles L, et al. Coronary artery motion and cardiac phases: dependency on heart rate - implications for CT image reconstruction. Radiology. 2007;245:567-576.
    • (2007) Radiology , vol.245 , pp. 567-576
    • Husmann, L.1    Leschka, S.2    Desbiolles, L.3
  • 15
    • 0036869547 scopus 로고    scopus 로고
    • Non-invasive coronary angiography with high resolution multidetector-row computed tomography - results in 102 patients
    • Kopp AF, Schroeder S, Kuettner A, et al. Non-invasive coronary angiography with high resolution multidetector-row computed tomography - results in 102 patients. Eur Heart J. 2002;23:1714-1725.
    • (2002) Eur Heart J , vol.23 , pp. 1714-1725
    • Kopp, A.F.1    Schroeder, S.2    Kuettner, A.3
  • 16
  • 17
    • 4444324085 scopus 로고    scopus 로고
    • Automatic phase determination for retrospectively gated cardiac CT
    • Manzke R, Kohler T, Nielsen T, et al. Automatic phase determination for retrospectively gated cardiac CT. Med Phys. 2004;31:3345-3362.
    • (2004) Med Phys , vol.31 , pp. 3345-3362
    • Manzke, R.1    Kohler, T.2    Nielsen, T.3
  • 18
    • 31444448156 scopus 로고    scopus 로고
    • Automatic determination of minimal cardiac motion phases for computed tomography imaging: Initial experience
    • Hoffmann MHK, Lessick J, Manzke R, et al. Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience. Eur Radiol. 2006;16:365-373.
    • (2006) Eur Radiol , vol.16 , pp. 365-373
    • Hoffmann, M.H.K.1    Lessick, J.2    Manzke, R.3
  • 19
    • 79551689848 scopus 로고    scopus 로고
    • Rawdata-based detection of the optimal reconstruction phase in ECG-gated cardiac image reconstruction
    • Ertel D, Kachelrieß M, Pflederer T, et al. Rawdata-based detection of the optimal reconstruction phase in ECG-gated cardiac image reconstruction. Proc MICCAILNCS. 2006;4191:348-355.
    • (2006) Proc MICCAILNCS , vol.4191 , pp. 348-355
    • Ertel, D.1    Kachelrieß, M.2    Pflederer, T.3
  • 21
    • 25444519367 scopus 로고    scopus 로고
    • Accuracy of MSCT coronary angiography with 64-slice technology: First experience
    • Leschka S, Alkadhi H, Plass A, et al. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J. 2005;26:1482-1487.
    • (2005) Eur Heart J , vol.26 , pp. 1482-1487
    • Leschka, S.1    Alkadhi, H.2    Plass, A.3
  • 22
    • 31144447047 scopus 로고    scopus 로고
    • Usefulness of multidetector row spiral computed tomography with 64 × 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses
    • Ropers D, Rixe J, Anders K, et al. Usefulness of multidetector row spiral computed tomography with 64 × 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol. 2006;97:343-348.
    • (2006) Am J Cardiol , vol.97 , pp. 343-348
    • Ropers, D.1    Rixe, J.2    Anders, K.3
  • 23
    • 0032603548 scopus 로고    scopus 로고
    • Dose reduction in CT by on-line tube current control: Principles and validation on phantoms and cadavers
    • Kalender WA, Wolf H, Suess C, et al. Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers. Eur Radiol. 1999;9:323-328.
    • (1999) Eur Radiol , vol.9 , pp. 323-328
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3
  • 24
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation
    • Jakobs TF, Becker CR, Ohnesorge B, et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol. 2002;12: 1081-1086.
    • (2002) Eur Radiol , vol.12 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3
  • 25
    • 33746206443 scopus 로고    scopus 로고
    • Multislice CT coronary angiography: Effect of sublingual nitroglycerine on the diameter of coronary arteries
    • Dewey M, Hoffmann H, Hamm B. Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Fortschr Rontgenstr. 2006;178:600-604.
    • (2006) Fortschr Rontgenstr , vol.178 , pp. 600-604
    • Dewey, M.1    Hoffmann, H.2    Hamm, B.3
  • 26
    • 0034855110 scopus 로고    scopus 로고
    • Novel approximate approach for high-quality image reconstruction in helical cone-beam CT at arbitrary pitch
    • Schaller S, Stierstorferw K, Bruder H, et al. Novel approximate approach for high-quality image reconstruction in helical cone-beam CT at arbitrary pitch. Proc SPIE. 2001;4322:113-127.
    • (2001) Proc SPIE , vol.4322 , pp. 113-127
    • Schaller, S.1    Stierstorferw, K.2    Bruder, H.3
  • 27
    • 10344230948 scopus 로고    scopus 로고
    • Performance evaluation of a 64-slice CT system with z-flying focal spot
    • Flohr T, Stierstorfer K, Raupach R, et al. Performance evaluation of a 64-slice CT system with z-flying focal spot. Fortschr Rontgenstr. 2004;176:1803-1810.
    • (2004) Fortschr Rontgenstr , vol.176 , pp. 1803-1810
    • Flohr, T.1    Stierstorfer, K.2    Raupach, R.3
  • 29
    • 33745015635 scopus 로고    scopus 로고
    • Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed
    • Wintersperger BJ, Nikolaou K, von Ziegler F, et al. Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest Radiol. 2006;41:436-442.
    • (2006) Invest Radiol , vol.41 , pp. 436-442
    • Wintersperger, B.J.1    Nikolaou, K.2    von Ziegler, F.3
  • 30
    • 10644242683 scopus 로고    scopus 로고
    • Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate
    • Hoffmann MHK, Shi H, Manzke R, et al. Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology. 2005;234:86-97.
    • (2005) Radiology , vol.234 , pp. 86-97
    • Hoffmann, M.H.K.1    Shi, H.2    Manzke, R.3
  • 31
    • 0017381382 scopus 로고
    • An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers
    • Landis JR, Koch GG. An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers. Biometrics. 1977;33:363-74.
    • (1977) Biometrics , vol.33 , pp. 363-374
    • Landis, J.R.1    Koch, G.G.2
  • 32
    • 66149188851 scopus 로고    scopus 로고
    • Real-time prediction of the heart phase for tube current modulation (TCM) by kymogram detection from spiral CT scans of the heart
    • Ertel D, Kachelrieß M, Kalender WA. Real-time prediction of the heart phase for tube current modulation (TCM) by kymogram detection from spiral CT scans of the heart. Eur Radiol Suppl. 2005;15:284.
    • (2005) Eur Radiol Suppl , vol.15 , pp. 284
    • Ertel, D.1    Kachelrieß, M.2    Kalender, W.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.