메뉴 건너뛰기




Volumn 18, Issue 2, 2008, Pages 253-262

Validation of a raw data-based synchronization signal (kymogram) for phase-correlated cardiac image reconstruction

Author keywords

Cardiac imaging; ECG; Heartmotion; Kymogram; Spiral CT

Indexed keywords

ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORRELATION ANALYSIS; ELECTROCARDIOGRAM; HEART DISEASE; HEART RATE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; SCORING SYSTEM; VALIDATION PROCESS;

EID: 39149106467     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-007-0752-5     Document Type: Article
Times cited : (8)

References (16)
  • 1
    • 0032414773 scopus 로고    scopus 로고
    • Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • Kachelrieß M, Kalender WA (1998) Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys 25(12):2417-2431
    • (1998) Med Phys , vol.25 , Issue.12 , pp. 2417-2431
    • Kachelrieß, M.1    Kalender, W.A.2
  • 2
    • 0033863629 scopus 로고    scopus 로고
    • ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    • Kachelrieß M, Ulzheimer S, Kalender WA (2000) ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med Phys 27(8):1881-1902
    • (2000) Med Phys , vol.27 , Issue.8 , pp. 1881-1902
    • Kachelrieß, M.1    Ulzheimer, S.2    Kalender, W.A.3
  • 3
    • 0034117652 scopus 로고    scopus 로고
    • High temporal resolution for multislice helical computed tomography
    • Taguchi K, Anno H (2000) High temporal resolution for multislice helical computed tomography. Med Phys 27(5):861-872
    • (2000) Med Phys , vol.27 , Issue.5 , pp. 861-872
    • Taguchi, K.1    Anno, H.2
  • 4
    • 0036596445 scopus 로고    scopus 로고
    • A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with supression of heart pulsation artifacts for cardio-thoratic imaging with extended volume coverage
    • Flohr T, Prokop M, Becker C, Schoepf UJ, Kopp AF, White RD, Schaller S, Ohnesorge B (2002) A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with supression of heart pulsation artifacts for cardio-thoratic imaging with extended volume coverage. Eur Radiol 12(6):1497-1503
    • (2002) Eur Radiol , vol.12 , Issue.6 , pp. 1497-1503
    • Flohr, T.1    Prokop, M.2    Becker, C.3    Schoepf, U.J.4    Kopp, A.F.5    White, R.D.6    Schaller, S.7    Ohnesorge, B.8
  • 5
    • 0024382423 scopus 로고
    • Internal densitometric gating for digital subtraction angiography
    • Seibert JA, Lantz MT, Brock J (1989) Internal densitometric gating for digital subtraction angiography. Invest Radiol 24(5):350-360
    • (1989) Invest Radiol , vol.24 , Issue.5 , pp. 350-360
    • Seibert, J.A.1    Lantz, M.T.2    Brock, J.3
  • 6
    • 39149103933 scopus 로고    scopus 로고
    • Computertomograph Mit Objektbezogener Bewegungsartefaktreduktion und Extraktion der Objektbewegungsinformation (Kymogramm)
    • European Patent Office, Patent pending, Patent No.: 99111708.6-1522
    • Willi A, Kalender WA, Kachelrieβ M (1999) Computertomograph mit objektbezogener Bewegungsartefaktreduktion und Extraktion der Objektbewegungsinformation (Kymogramm). European Patent Office, Patent pending, Patent No.: 99111708.6-1522
    • (1999)
    • Willi, A.1    Kalender, W.A.2    Kachelrieβ, M.3
  • 7
    • 0035996436 scopus 로고    scopus 로고
    • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • Kachelrieβ M, Sennst DA, Maxlmoser W, Kalender WA (2002) Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys 29(7):1489-1503
    • (2002) Med Phys , vol.29 , Issue.7 , pp. 1489-1503
    • Kachelrieβ, M.1    Sennst, D.A.2    Maxlmoser, W.3    Kalender, W.A.4
  • 8
    • 0041738095 scopus 로고    scopus 로고
    • Cardiac spiral imaging in Computed Tomography without ECG using complementary projections for motion detection
    • Bruder H, Maguet E, Stierstorfer K, Flohr T (2003) Cardiac spiral imaging in Computed Tomography without ECG using complementary projections for motion detection. Proc SPIE 5032:1798-1809
    • (2003) Proc SPIE , vol.5032 , pp. 1798-1809
    • Bruder, H.1    Maguet, E.2    Stierstorfer, K.3    Flohr, T.4
  • 9
    • 4444324085 scopus 로고    scopus 로고
    • Automatic phase determination for retrospectively gated cardiac CT
    • Manzke R, Köhler T, Nielsen T, Hawkes D, Grass M (2004) Automatic phase determination for retrospectively gated cardiac CT. Med Phys 31(12):3345-3362
    • (2004) Med Phys , vol.31 , Issue.12 , pp. 3345-3362
    • Manzke, R.1    Köhler, T.2    Nielsen, T.3    Hawkes, D.4    Grass, M.5
  • 11
    • 39149145736 scopus 로고    scopus 로고
    • Kymogram-based cardiac CT image reconstruction
    • In: Kalender WA (ed) Shaker, Aachen
    • Ertel D (2007) Kymogram-based cardiac CT image reconstruction. In: Kalender WA (ed) Berichte aus dem Institut für Medizinische Physik. Shaker, Aachen
    • (2007) Berichte Aus Dem Institut Für Medizinische Physik
    • Ertel, D.1
  • 12
    • 0033999358 scopus 로고    scopus 로고
    • Advanced single-slice rebinning in cone-beam spiral CT
    • Kachelrieβ M, Schaller S, Kalender WA (2000) Advanced single-slice rebinning in cone-beam spiral CT. Med Phys 27(4):754-772
    • (2000) Med Phys , vol.27 , Issue.4 , pp. 754-772
    • Kachelrieβ, M.1    Schaller, S.2    Kalender, W.A.3
  • 13
    • 0034855110 scopus 로고    scopus 로고
    • Novel approximate approach for high-quality image reconstruction in helical cone-beam CT at arbitrary pitch
    • Schaller S, Stierstorfer K, Bruder H, Kachelrieβ M, Flohr T (2001) Novel approximate approach for high-quality image reconstruction in helical cone-beam CT at arbitrary pitch. Proc SPIE 4322:113-127
    • (2001) Proc SPIE , vol.4322 , pp. 113-127
    • Schaller, S.1    Stierstorfer, K.2    Bruder, H.3    Kachelrieβ, M.4    Flohr, T.5
  • 14
    • 0037573220 scopus 로고    scopus 로고
    • Image reconstruction and image quality evaluation for a 16-slice CT scanner
    • Flohr T, Stierstorfer K, Bruder H, Simon J, Polacin A, Schaller S (2003) Image reconstruction and image quality evaluation for a 16-slice CT scanner. Med Phys 30(5):832-845
    • (2003) Med Phys , vol.30 , Issue.5 , pp. 832-845
    • Flohr, T.1    Stierstorfer, K.2    Bruder, H.3    Simon, J.4    Polacin, A.5    Schaller, S.6
  • 15
    • 0017381382 scopus 로고
    • An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers
    • Landis JR, Koch GG (1977) An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers. Biometrics 33(2):363-374
    • (1977) Biometrics , vol.33 , Issue.2 , pp. 363-374
    • Landis, J.R.1    Koch, G.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.