메뉴 건너뛰기




Volumn , Issue , 2008, Pages 5741-5744

Wearable technology for bio-chemical analysis of body fluids during exercise

Author keywords

[No Author keywords available]

Indexed keywords

BODY FLUIDS; CHEMICAL ANALYSIS; PH; PH SENSORS; SODIUM;

EID: 61849156263     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2008.4650518     Document Type: Conference Paper
Times cited : (27)

References (17)
  • 3
    • 24644459921 scopus 로고    scopus 로고
    • The Development and Characterisation of Conducting Polymeric-based Sensing Devices
    • S. Brady, K.T. Lau, W. Megill, G.G. Wallace and D. Diamond, "The Development and Characterisation of Conducting Polymeric-based Sensing Devices," Synthetic Metals, vol. 154, pp. 25-28, 2005.
    • (2005) Synthetic Metals , vol.154 , pp. 25-28
    • Brady, S.1    Lau, K.T.2    Megill, W.3    Wallace, G.G.4    Diamond, D.5
  • 4
    • 84977704697 scopus 로고
    • Fluid and electrolyte balance in prolonged exercise
    • J. Maughan, "Fluid and electrolyte balance in prolonged exercise," Nutrition Bulletin, vol. 10, pp. 28-35, 1985.
    • (1985) Nutrition Bulletin , vol.10 , pp. 28-35
    • Maughan, J.1
  • 5
    • 33745699642 scopus 로고    scopus 로고
    • Novel lactate and pH biosensor for skin and sweat analysis based on single walled carbon nanotubes
    • J. Weber, A. Kumar and S. Bhansali, "Novel lactate and pH biosensor for skin and sweat analysis based on single walled carbon nanotubes," Sensors and Actuators B, vol. 117, pp. 308-313, 2006.
    • (2006) Sensors and Actuators B , vol.117 , pp. 308-313
    • Weber, J.1    Kumar, A.2    Bhansali, S.3
  • 6
    • 0346741407 scopus 로고    scopus 로고
    • National Athletic Trainers' Association Position Statement: Fluid Replacement for Athletes
    • D.J. Casa, L.E. Armstrong, S.J. Montain, B.S.E. Rich and J.A. Stone, "National Athletic Trainers' Association Position Statement: Fluid Replacement for Athletes," Journal of Athletic Training, vol. 35, pp. 212-224, 2000.
    • (2000) Journal of Athletic Training , vol.35 , pp. 212-224
    • Casa, D.J.1    Armstrong, L.E.2    Montain, S.J.3    Rich, B.S.E.4    Stone, J.A.5
  • 7
    • 0034713429 scopus 로고    scopus 로고
    • H.J. Adrogue and N.E. Madias, Hyponatremia, Primary Care, 342, pp. 1581-1589.
    • H.J. Adrogue and N.E. Madias, "Hyponatremia," Primary Care, vol. 342, pp. 1581-1589.
  • 9
    • 0033665646 scopus 로고    scopus 로고
    • Variations in regional sweat composition in normal human males
    • M.J. Patterson, S.D.R. Galloway and M.A. Nimmo, "Variations in regional sweat composition in normal human males," Experimental Physiology, vol. 85, pp. 869-875, 2000.
    • (2000) Experimental Physiology , vol.85 , pp. 869-875
    • Patterson, M.J.1    Galloway, S.D.R.2    Nimmo, M.A.3
  • 11
    • 33645137576 scopus 로고    scopus 로고
    • Quantitative colourmetric analysis of dye mixtures using an optical photometer based on LED array
    • K.T. Lau, W.S. Yerzunis, R.L. Shepard and D. Diamond, "Quantitative colourmetric analysis of dye mixtures using an optical photometer based on LED array," Sensors and Actuators B, vol. 114, pp. 819-825, 2006.
    • (2006) Sensors and Actuators B , vol.114 , pp. 819-825
    • Lau, K.T.1    Yerzunis, W.S.2    Shepard, R.L.3    Diamond, D.4
  • 12
    • 14744271872 scopus 로고    scopus 로고
    • A polypyrrolebased solid contact Pb2+ -selective PVC-membrane electrode with a nanomolar detection limit
    • J. Sutter, E. Lindner, R.E. Gyurcsányi and E. Pretsch, "A polypyrrolebased solid contact Pb2+ -selective PVC-membrane electrode with a nanomolar detection limit," Analytical and Bioanalytical Chemistry, vol. 380, pp. 7-14, 2004.
    • (2004) Analytical and Bioanalytical Chemistry , vol.380 , pp. 7-14
    • Sutter, J.1    Lindner, E.2    Gyurcsányi, R.E.3    Pretsch, E.4
  • 14
    • 0001547159 scopus 로고
    • A sodium ion-selective electrode based on methyl p-t-butylcalix[4]aryl acetate as the ionophore
    • D. Diamond, G. Svehla, E.M. Seward and M.A. McKervey, "A sodium ion-selective electrode based on methyl p-t-butylcalix[4]aryl acetate as the ionophore," Analytica Chimica Acta, vol. 204, pp. 223-231, 1988.
    • (1988) Analytica Chimica Acta , vol.204 , pp. 223-231
    • Diamond, D.1    Svehla, G.2    Seward, E.M.3    McKervey, M.A.4
  • 15
    • 37049082812 scopus 로고
    • Inverted poly(vinyl chloride) - liquid membrane ion-selective electrodes for high-speed batch injection potentiometric analysis
    • J. Lu, Q. Chen, D. Diamond and J. Wang, "Inverted poly(vinyl chloride) - liquid membrane ion-selective electrodes for high-speed batch injection potentiometric analysis," Analyst, vol. 118, pp. 1131-1135, 1993.
    • (1993) Analyst , vol.118 , pp. 1131-1135
    • Lu, J.1    Chen, Q.2    Diamond, D.3    Wang, J.4
  • 17
    • 4544273966 scopus 로고    scopus 로고
    • Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range
    • J. Sutter, A. Radu, P. Shane, E. Bakker and E. Pretsch, "Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range," Analytica Chimica Acta, vol. 523, pp. 53-59, 2004.
    • (2004) Analytica Chimica Acta , vol.523 , pp. 53-59
    • Sutter, J.1    Radu, A.2    Shane, P.3    Bakker, E.4    Pretsch, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.