메뉴 건너뛰기




Volumn , Issue , 2008, Pages 2039-2042

A ultra high field multi-element transceive volume array for small animal MRI

Author keywords

[No Author keywords available]

Indexed keywords

ENGINEERING; INDUSTRIAL ENGINEERING;

EID: 61849134573     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2008.4649592     Document Type: Conference Paper
Times cited : (5)

References (12)
  • 1
    • 0033945956 scopus 로고    scopus 로고
    • Sensitivity and power deposition in a high-field imaging experiment
    • D.I. Hoult, "Sensitivity and power deposition in a high-field imaging experiment," J. Magn. Reson. Imag., vol. 12(1), pp. 46-67, 2000.
    • (2000) J. Magn. Reson. Imag , vol.12 , Issue.1 , pp. 46-67
    • Hoult, D.I.1
  • 2
    • 0034962138 scopus 로고    scopus 로고
    • 7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
    • J.T. Vaughan et al, "7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images," Magn. Reson. Med., vol. 46(1), pp. 24-30, 2001.
    • (2001) Magn. Reson. Med , vol.46 , Issue.1 , pp. 24-30
    • Vaughan, J.T.1
  • 3
    • 0035685766 scopus 로고    scopus 로고
    • Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonator
    • T.S. Ibrahim et al, "Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonator," Magn. Reson. Med., vol. 19(10), pp. 1339-1347, 2001.
    • (2001) Magn. Reson. Med , vol.19 , Issue.10 , pp. 1339-1347
    • Ibrahim, T.S.1
  • 4
    • 33646383376 scopus 로고    scopus 로고
    • Multiple-acquisition parallel imaging combined with a transceive array for the amelioration of high-field RF distortion: A modeling study
    • B. K. Li, B. Xu, F. Liu, and S. Crozier, "Multiple-acquisition parallel imaging combined with a transceive array for the amelioration of high-field RF distortion: a modeling study," Concepts Magn. Reson. Eng., vol. 29B(2), pp. 95-105, 2006.
    • (2006) Concepts Magn. Reson. Eng , vol.29 B , Issue.2 , pp. 95-105
    • Li, B.K.1    Xu, B.2    Liu, F.3    Crozier, S.4
  • 5
    • 27644503224 scopus 로고    scopus 로고
    • A theoretical comparison of two optimization methods for radiofrequency drive schemes in high frequency MRI resonators
    • F. Liu, B.L. Beck, J.R Fitzsimmons, S.J. Blackband, S. Crozier, "A theoretical comparison of two optimization methods for radiofrequency drive schemes in high frequency MRI resonators," Phys. Med. Biol., vol. 50(22), pp. 5281-5291, 2005.
    • (2005) Phys. Med. Biol , vol.50 , Issue.22 , pp. 5281-5291
    • Liu, F.1    Beck, B.L.2    Fitzsimmons, J.R.3    Blackband, S.J.4    Crozier, S.5
  • 6
    • 12844272274 scopus 로고    scopus 로고
    • Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B-1 inhomogeneity at 3 T
    • S. Saekho, F.E. Boada, D.C. Noll, V.A. Stenger, "Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B-1 inhomogeneity at 3 T," Magn. Reson. Med., vol. 53(2), pp. 479-484, 2005.
    • (2005) Magn. Reson. Med , vol.53 , Issue.2 , pp. 479-484
    • Saekho, S.1    Boada, F.E.2    Noll, D.C.3    Stenger, V.A.4
  • 9
    • 33947244465 scopus 로고    scopus 로고
    • High-field magnetic resonance imaging with reduced field/tissue RF artefacts - A modeling study using hybrid MoM/FEM and FDTD technique
    • B.K. Li, F. Liu, S. Crozier, "High-field magnetic resonance imaging with reduced field/tissue RF artefacts - A modeling study using hybrid MoM/FEM and FDTD technique," IEEE Trans. Electromag. Compt., vol. 48(4), pp. 628-633, 2006.
    • (2006) IEEE Trans. Electromag. Compt , vol.48 , Issue.4 , pp. 628-633
    • Li, B.K.1    Liu, F.2    Crozier, S.3
  • 10
    • 57649195764 scopus 로고    scopus 로고
    • A fast parallel imaging rotary phased array head coil with improved sensitivity profile deep in the center of the human brain, 29th Annual
    • E.Weber, B.K. Li, F Liu, S. Crozier, "A fast parallel imaging rotary phased array head coil with improved sensitivity profile deep in the center of the human brain," 29th Annual IEEE Eng. Med. Biol. Soc., vol. 29, pp. 504-507, 2007.
    • (2007) IEEE Eng. Med. Biol. Soc , vol.29 , pp. 504-507
    • Weber, E.1    Li, B.K.2    Liu, F.3    Crozier, S.4
  • 11
    • 61849133105 scopus 로고    scopus 로고
    • E. Weber, B.K. Li, S. Crozier, MRI Coil Decoupling, Australia Provision Patent 2007901587, 2007.
    • E. Weber, B.K. Li, S. Crozier, "MRI Coil Decoupling," Australia Provision Patent 2007901587, 2007.
  • 12
    • 0036263907 scopus 로고    scopus 로고
    • Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    • [12]M.A. Griswold et al, "Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)," Magn. Reson. Med., vol. 47(6), pp. 1202-1210, 2002.
    • (2002) Magn. Reson. Med , vol.47 , Issue.6 , pp. 1202-1210
    • Griswold, M.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.