메뉴 건너뛰기




Volumn , Issue , 2007, Pages 504-507

A fast parallel imaging rotary phased array head coil with improved sensitivity profile deep in the center of the brain

Author keywords

[No Author keywords available]

Indexed keywords

PARALLEL IMAGING; VD-GRAPPA;

EID: 57649195764     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352333     Document Type: Conference Paper
Times cited : (7)

References (12)
  • 3
    • 0036263907 scopus 로고    scopus 로고
    • Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    • M. A. Griswold et al., "Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)," Magn. Reson. Med., vol. 47(6), pp. 1202-1210, 2002.
    • (2002) Magn. Reson. Med , vol.47 , Issue.6 , pp. 1202-1210
    • Griswold, M.A.1
  • 4
    • 22744434112 scopus 로고    scopus 로고
    • Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T
    • R. G. Pinkerton, E. A. Barberi and R. S. Menon, "Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T," Magn. Reson. Med., vol. 54(2), pp. 499-503, 2005.
    • (2005) Magn. Reson. Med , vol.54 , Issue.2 , pp. 499-503
    • Pinkerton, R.G.1    Barberi, E.A.2    Menon, R.S.3
  • 5
    • 19544387778 scopus 로고    scopus 로고
    • B. K Li, F. Liu and S. Crozier S, Focused, eight-element transceive phased array coil for parallel magnetic resonance imaging of the chest-theoretical considerations, Magn. Reson. Med., 53(6), pp. 1251-1257, 2005.
    • B. K Li, F. Liu and S. Crozier S, "Focused, eight-element transceive phased array coil for parallel magnetic resonance imaging of the chest-theoretical considerations," Magn. Reson. Med., vol. 53(6), pp. 1251-1257, 2005.
  • 6
    • 0031877408 scopus 로고    scopus 로고
    • A 16-element phased-array head coil
    • J. R. Porter, S. M. Wright, A. Reykowski, "A 16-element phased-array head coil," Magn. Reson. Med., vol. 40(2), pp. 272-279, 1998.
    • (1998) Magn. Reson. Med , vol.40 , Issue.2 , pp. 272-279
    • Porter, J.R.1    Wright, S.M.2    Reykowski, A.3
  • 7
    • 33745685594 scopus 로고    scopus 로고
    • 32-Channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry
    • G. C. Wiggins et al., "32-Channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry," Magn. Reson. Med., vol. 56(1), pp. 216-223, 2006.
    • (2006) Magn. Reson. Med , vol.56 , Issue.1 , pp. 216-223
    • Wiggins, G.C.1
  • 8
    • 33947244465 scopus 로고    scopus 로고
    • High High-field magnetic resonance imaging with reduced field/tissue RF artefacts - A modeling study using hybrid MoM/FEM and FDTD technique
    • B. K. Li, F. Liu, and S. Crozier, "High High-field magnetic resonance imaging with reduced field/tissue RF artefacts - A modeling study using hybrid MoM/FEM and FDTD technique," IEEE Trans. Electromagn. Compat., vol 48(4), pp. 628-633, 2006.
    • (2006) IEEE Trans. Electromagn. Compat , vol.48 , Issue.4 , pp. 628-633
    • Li, B.K.1    Liu, F.2    Crozier, S.3
  • 9
    • 38049009334 scopus 로고    scopus 로고
    • An Experimental Verification of a Hybrid MoM/FEM Method for RF Simulations in MRI
    • Berlin, to be published
    • B. K. Li, E. Weber, B. Beck, S. Blackband and S. Crozier, "An Experimental Verification of a Hybrid MoM/FEM Method for RF Simulations in MRI," in Proc. 15th Annu. Meeting of ISMRM, Berlin, 2007, to be published.
    • (2007) Proc. 15th Annu. Meeting of ISMRM
    • Li, B.K.1    Weber, E.2    Beck, B.3    Blackband, S.4    Crozier, S.5
  • 10
    • 12144268779 scopus 로고    scopus 로고
    • J. Park, Q. Zhang Q, V. Jellus, O. Simonetti and D. B. Li, Artifact and noise suppression in GRAPPA imaging using improved k-space coil calibration and variable density sampling, Magn. Reson. Med., 53(1), pp. 186-193, 2005.
    • J. Park, Q. Zhang Q, V. Jellus, O. Simonetti and D. B. Li, "Artifact and noise suppression in GRAPPA imaging using improved k-space coil calibration and variable density sampling," Magn. Reson. Med., vol. 53(1), pp. 186-193, 2005.
  • 11
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • J.G. Pipe, "Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging," Magn. Reson. Med., vol. 42(5), pp. 963-969, 1999.
    • (1999) Magn. Reson. Med , vol.42 , Issue.5 , pp. 963-969
    • Pipe, J.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.