메뉴 건너뛰기




Volumn , Issue , 2008, Pages 3643-3648

Effect of fiducial configuration on target registration error in intraoperative cone-beam CT guidance of head and neck surgery

Author keywords

[No Author keywords available]

Indexed keywords

PATIENT REHABILITATION; ROBOTIC ARMS; TRANSPLANTATION (SURGICAL);

EID: 61849105516     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2008.4649997     Document Type: Conference Paper
Times cited : (21)

References (8)
  • 1
    • 12844254281 scopus 로고    scopus 로고
    • Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery
    • J.H. Siewerdsen, et al., "Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery." Medical Physics, Vol. 31(1), pp. 241-254, 2006
    • (2006) Medical Physics , vol.31 , Issue.1 , pp. 241-254
    • Siewerdsen, J.H.1
  • 2
    • 33749385433 scopus 로고    scopus 로고
    • Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype
    • M. J. Daly, J. H. Siewerdsen, D. J. Moseley, D. A. Jaffray, and J. C. Irish, "Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype," Medical Physic, Vol. 38(10), pp. 3767-3780, 2006.
    • (2006) Medical Physic , vol.38 , Issue.10 , pp. 3767-3780
    • Daly, M.J.1    Siewerdsen, J.H.2    Moseley, D.J.3    Jaffray, D.A.4    Irish, J.C.5
  • 3
    • 0035061427 scopus 로고    scopus 로고
    • Fiducial point placement and the accuracy of point-based, rigid body registration
    • April
    • J. B. West, J. M. Fitzpatrick, S. A. Toms, C. R. Maurer, R. J. Maciunas, "Fiducial point placement and the accuracy of point-based, rigid body registration", Neurosurgery, Vol. 48, No. 4, pp. 810-817, April 2001
    • (2001) Neurosurgery , vol.48 , Issue.4 , pp. 810-817
    • West, J.B.1    Fitzpatrick, J.M.2    Toms, S.A.3    Maurer, C.R.4    Maciunas, R.J.5
  • 4
    • 84975553202 scopus 로고
    • Closed-form solution of absolute orientation using unit quaternions
    • April
    • B. K. Horn, "Closed-form solution of absolute orientation using unit quaternions", Optical Society of America, Vol. 4, No. 4, pp. 629-642, April 1987
    • (1987) Optical Society of America , vol.4 , Issue.4 , pp. 629-642
    • Horn, B.K.1
  • 5
  • 6
    • 40149095934 scopus 로고    scopus 로고
    • A statistical model for point-based target registration error with anisotropic fiducial localizer error
    • March
    • A. D. Wiles, A. Likholyot, D. D. Frantz, T. M. Peters, "A statistical model for point-based target registration error with anisotropic fiducial localizer error", IEEE Transactions on Medical Imaging, Vol. 27, No. 3, pp. 378-390, March 2008
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , Issue.3 , pp. 378-390
    • Wiles, A.D.1    Likholyot, A.2    Frantz, D.D.3    Peters, T.M.4
  • 8
    • 2542476140 scopus 로고    scopus 로고
    • Designing optically tracked instruments for image-guided surgery
    • May
    • J. B. West, C. R. Maurer, "Designing optically tracked instruments for image-guided surgery", IEEE Transactions on Medical Imaging, Vol. 23, No. 5, pg. 553-545 May 2004
    • (2004) IEEE Transactions on Medical Imaging , vol.23 , Issue.5 , pp. 553-545
    • West, J.B.1    Maurer, C.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.