메뉴 건너뛰기




Volumn 3, Issue 1, 2008, Pages

Investigation of the usability of conebeam CT data sets for dose calculation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DOSIMETRY; HEAD; HUMAN; IMAGE PROCESSING; IMAGING SYSTEM; PELVIC DISEASE; PHANTOM; RADIATION BEAM; RADIATION DOSE DISTRIBUTION; RADIOLOGICAL PARAMETERS; REFERENCE VALUE; THORAX DISEASE; TREATMENT PLANNING; CALIBRATION; COMPUTER ASSISTED RADIOTHERAPY; CONE BEAM COMPUTED TOMOGRAPHY; EVALUATION; FEASIBILITY STUDY; IMAGE QUALITY; INSTRUMENTATION; MALE; METHODOLOGY; NEOPLASM; PELVIS; RADIATION DOSE; RADIATION EXPOSURE; RADIOGRAPHY; RETROSPECTIVE STUDY; STANDARD; THORAX; THORAX RADIOGRAPHY;

EID: 61849095754     PISSN: None     EISSN: 1748717X     Source Type: Journal    
DOI: 10.1186/1748-717X-3-42     Document Type: Article
Times cited : (166)

References (29)
  • 1
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • 10.1016/S0360-3016(02)02884-5 12128137
    • Jaffray DA Siewerdsen JH Wong JW: Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 2002, 53:1337-1349. 10.1016/S0360-3016(02)02884-5 12128137
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3
  • 2
    • 43249095706 scopus 로고    scopus 로고
    • Conventionally-fractionated image-guided intensity modulated radiotherapy (IG-IMRT): A safe and effective treatment for cancer spinal metastasis
    • 2373792 18426607 10.1186/1748-717X-3-11
    • Gong Y Wang J Bai S: Conventionally-fractionated image-guided intensity modulated radiotherapy (IG-IMRT): A safe and effective treatment for cancer spinal metastasis. Radiat Oncol 2008, 3:11. 2373792 18426607 10.1186/1748-717X-3-11
    • (2008) Radiat Oncol , vol.3 , pp. 11
    • Gong, Y.1    Wang, J.2    Bai, S.3
  • 3
    • 33847306482 scopus 로고    scopus 로고
    • Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table
    • 17336222
    • Meyer J Wilbert J Baier K: Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table. Int J Radiat Oncol Biol Phys 2007, 67:1220-1228. 17336222
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1220-1228
    • Meyer, J.1    Wilbert, J.2    Baier, K.3
  • 4
    • 22444451154 scopus 로고    scopus 로고
    • Cone-beam-CT guided radiation therapy: A model for on-line application
    • 10.1016/j.radonc.2005.03.026 15890419
    • Oldham M Letourneau D Watt L: Cone-beam-CT guided radiation therapy: A model for on-line application. Radiother Oncol 2005, 75:271-278. 10.1016/ j.radonc.2005.03.026 15890419
    • (2005) Radiother Oncol , vol.75 , pp. 271-278
    • Oldham, M.1    Letourneau, D.2    Watt, L.3
  • 5
    • 1642528349 scopus 로고    scopus 로고
    • Daily target localization for prostate patients based on 3D image correlation
    • 10.1088/0031-9155/49/6/005 15104317
    • Paskalev K Ma CM Jacob R: Daily target localization for prostate patients based on 3D image correlation. Phys Med Biol 2004, 49:931-939. 10.1088/0031-9155/49/6/005 15104317
    • (2004) Phys Med Biol , vol.49 , pp. 931-939
    • Paskalev, K.1    Ma, C.M.2    Jacob, R.3
  • 6
    • 34548314016 scopus 로고    scopus 로고
    • Nonrigid patient setup errors in the head-and-neck region
    • 10.1007/s00066-007-1747-5 17762925
    • Polat B Wilbert J Baier K: Nonrigid patient setup errors in the head-and-neck region. Strahlenther Onkol 2007, 183:506-511. 10.1007/ s00066-007-1747-5 17762925
    • (2007) Strahlenther Onkol , vol.183 , pp. 506-511
    • Polat, B.1    Wilbert, J.2    Baier, K.3
  • 7
    • 51049088404 scopus 로고    scopus 로고
    • Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC
    • 10.1080/02841860802251567 18654908
    • Jensen HR Hansen O Hjelm-Hansen M: Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC. Acta Oncol 2008, 47:1432-1437. 10.1080/02841860802251567 18654908
    • (2008) Acta Oncol , vol.47 , pp. 1432-1437
    • Jensen, H.R.1    Hansen, O.2    Hjelm-Hansen, M.3
  • 8
    • 38349078986 scopus 로고    scopus 로고
    • A (short) history of image-guided radiotherapy
    • 10.1016/j.radonc.2007.11.023 18083259
    • Verellen D De Ridder M Storme G: A (short) history of image-guided radiotherapy. Radiother Oncol 2008, 86:4-13. 10.1016/ j.radonc.2007.11.023 18083259
    • (2008) Radiother Oncol , vol.86 , pp. 4-13
    • Verellen, D.1    De Ridder, M.2    Storme, G.3
  • 9
    • 36448939132 scopus 로고    scopus 로고
    • Innovations in image-guided radiotherapy
    • 10.1038/nrc2288 18034185
    • Verellen D Ridder MD: Linthout N Innovations in image-guided radiotherapy. Nat Rev Cancer 2007, 7:949-960. 10.1038/nrc2288 18034185
    • (2007) Nat Rev Cancer , vol.7 , pp. 949-960
    • Verellen, D.1    Ridder, M.D.2    Linthout, N.3
  • 10
    • 33748875872 scopus 로고    scopus 로고
    • Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors
    • 10.1080/02841860600904839 16982556
    • Guckenberger M Meyer J Wilbert J: Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncol 2006, 45:897-906. 10.1080/02841860600904839 16982556
    • (2006) Acta Oncol , vol.45 , pp. 897-906
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3
  • 11
    • 33847250480 scopus 로고    scopus 로고
    • Dose calculation using megavoltage cone-beam CT
    • 17336221
    • Morin O Chen J Aubin M: Dose calculation using megavoltage cone-beam CT. Int J Radiat Oncol Biol Phys 2007, 67:1201-1210. 17336221
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1201-1210
    • Morin, O.1    Chen, J.2    Aubin, M.3
  • 12
    • 51049094214 scopus 로고    scopus 로고
    • Volumetric image-guidance: Does routine usage prompt adaptive re-planning? An institutional review
    • 10.1080/02841860802279741 18661434
    • Tanyi JA Fuss MH: Volumetric image-guidance: Does routine usage prompt adaptive re-planning? An institutional review. Acta Oncol 2008, 47:1444-1453. 10.1080/02841860802279741 18661434
    • (2008) Acta Oncol , vol.47 , pp. 1444-1453
    • Tanyi, J.A.1    Fuss, M.H.2
  • 13
    • 33847259277 scopus 로고    scopus 로고
    • Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: Image quality and system performance
    • 17336223
    • Letourneau D Wong R Moseley D: Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: Image quality and system performance. Int J Radiat Oncol Biol Phys 2007, 67:1229-1237. 17336223
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1229-1237
    • Letourneau, D.1    Wong, R.2    Moseley, D.3
  • 14
    • 84986543163 scopus 로고    scopus 로고
    • Dose calculation on cone beam CT (CBCT)
    • 10.1118/1.2760822
    • Chi Y Wu Q Yan D: Dose calculation on cone beam CT (CBCT). Medical Physics 2007, 34:2438. 10.1118/1.2760822
    • (2007) Medical Physics , vol.34 , pp. 2438
    • Chi, Y.1    Wu, Q.2    Yan, D.3
  • 15
    • 36349028639 scopus 로고    scopus 로고
    • Cone-beam CT Hounsfield unit correction method and application on images of the pelvic region
    • Depuydt T Hrbacek J Slagmolen P: Cone-beam CT Hounsfield unit correction method and application on images of the pelvic region. Radiotherapy and oncology 2006, 81(Supplement 1):29.
    • (2006) Radiotherapy and Oncology , vol.81 , Issue.SUPPL. 1 , pp. 29
    • Depuydt, T.1    Hrbacek, J.2    Slagmolen, P.3
  • 16
    • 61849180650 scopus 로고    scopus 로고
    • Quantitive Evaluation of Cone Beam CT Data Used for Treatment Planning
    • 10.1118/1.2241926
    • Houser C Nawaz AO Galvin J: Quantitive Evaluation of Cone Beam CT Data Used for Treatment Planning. Medical Physics 2006, 33:2285-2286. 10.1118/ 1.2241926
    • (2006) Medical Physics , vol.33 , pp. 2285-2286
    • Houser, C.1    Nawaz, A.O.2    Galvin, J.3
  • 17
    • 38149080615 scopus 로고    scopus 로고
    • Retrospective IMRT Dose Reconstruction Based on Cone-Beam CT and MLC Log-File
    • 18207036
    • Lee L Le QT Xing L: Retrospective IMRT Dose Reconstruction Based on Cone-Beam CT and MLC Log-File. Int J Radiat Oncol Biol Phys 2008, 70:634-644. 18207036
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 634-644
    • Lee, L.1    Le, Q.T.2    Xing, L.3
  • 18
    • 58149231345 scopus 로고    scopus 로고
    • Shading correction algorithm for improvement of cone-beam CT images in radiotherapy
    • 10.1088/0031-9155/53/20/010 18824785
    • Marchant TE Moore CJ Rowbottom CG: Shading correction algorithm for improvement of cone-beam CT images in radiotherapy. Phys Med Biol 2008, 53:5719-5733. 10.1088/0031-9155/53/20/010 18824785
    • (2008) Phys Med Biol , vol.53 , pp. 5719-5733
    • Marchant, T.E.1    Moore, C.J.2    Rowbottom, C.G.3
  • 19
    • 61849110115 scopus 로고    scopus 로고
    • Cone beam CT based treatment planning
    • 10.1118/1.2240820
    • Paliwal B Tewatia D Orton N: Cone beam CT based treatment planning. Medical Physics 2006, 33:2029. 10.1118/1.2240820
    • (2006) Medical Physics , vol.33 , pp. 2029
    • Paliwal, B.1    Tewatia, D.2    Orton, N.3
  • 20
    • 36349000656 scopus 로고    scopus 로고
    • Dose calculation on linac integrated KV-cone beam CT
    • Tucking T Nill S Oelfke U: Dose calculation on linac integrated KV-cone beam CT. Radiotherapy and oncology 2006, 81(Supplement 1):26
    • (2006) Radiotherapy and Oncology , vol.81 , Issue.SUPPL. 1 , pp. 26
    • Tucking, T.1    Nill, S.2    Oelfke, U.3
  • 21
    • 36348944594 scopus 로고    scopus 로고
    • Correction of conebeam CT values using a planning CT for derivation of the "dose of the day"
    • 10.1016/j.radonc.2007.08.010 17936387
    • van Zijtveld M Dirkx M Heijmen B: Correction of conebeam CT values using a planning CT for derivation of the "dose of the day". Radiother Oncol 2007, 85:195-200. 10.1016/j.radonc.2007.08.010 17936387
    • (2007) Radiother Oncol , vol.85 , pp. 195-200
    • van Zijtveld, M.1    Dirkx, M.2    Heijmen, B.3
  • 22
    • 34047264975 scopus 로고    scopus 로고
    • Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation
    • 10.1088/0031-9155/52/3/011 17228114
    • Yang Y Schreibmann E Li T: Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation. Phys Med Biol 2007, 52:685-705. 10.1088/ 0031-9155/52/3/011 17228114
    • (2007) Phys Med Biol , vol.52 , pp. 685-705
    • Yang, Y.1    Schreibmann, E.2    Li, T.3
  • 23
    • 33751177982 scopus 로고    scopus 로고
    • Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning
    • 17056197
    • Yoo S Yin FF: Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning. Int J Radiat Oncol Biol Phys 2006, 66:1553-1561. 17056197
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 1553-1561
    • Yoo, S.1    Yin, F.F.2
  • 24
    • 0035110308 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
    • 10.1118/1.1339879 11243347
    • Siewerdsen JH Jaffray DA: Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter. Med Phys 2001, 28:220-231. 10.1118/1.1339879 11243347
    • (2001) Med Phys , vol.28 , pp. 220-231
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 25
    • 0018760007 scopus 로고
    • The direct use of CT numbers in radiotherapy dosage calculations for inhomogeneous media
    • 10.1088/0031-9155/24/4/011 472014
    • Parker RP Hobday PA Cassell KJ: The direct use of CT numbers in radiotherapy dosage calculations for inhomogeneous media. Phys Med Biol 1979, 24:802-809. 10.1088/0031-9155/24/4/011 472014
    • (1979) Phys Med Biol , vol.24 , pp. 802-809
    • Parker, R.P.1    Hobday, P.A.2    Cassell, K.J.3
  • 26
    • 23844557643 scopus 로고    scopus 로고
    • Determination of CT-to-density conversion relationship for image-based treatment planning systems
    • 10.1016/j.meddos.2005.05.001 16112465
    • Saw CB Loper A Komanduri K: Determination of CT-to-density conversion relationship for image-based treatment planning systems. Med Dosim 2005, 30:145-148. 10.1016/j.meddos.2005.05.001 16112465
    • (2005) Med Dosim , vol.30 , pp. 145-148
    • Saw, C.B.1    Loper, A.2    Komanduri, K.3
  • 27
    • 0026749824 scopus 로고
    • An electron density calibration phantom for CT-based treatment planning computers
    • 10.1118/1.596862 1584125
    • Constantinou C Harrington JC DeWerd LA: An electron density calibration phantom for CT-based treatment planning computers. Med Phys 1992, 19:325-327. 10.1118/1.596862 1584125
    • (1992) Med Phys , vol.19 , pp. 325-327
    • Constantinou, C.1    Harrington, J.C.2    DeWerd, L.A.3
  • 29
    • 0030065290 scopus 로고    scopus 로고
    • The calibration of CT Hounsfield units for radiotherapy treatment planning
    • 10.1088/0031-9155/41/1/009 8685250
    • Schneider U Pedroni E Lomax A: The calibration of CT Hounsfield units for radiotherapy treatment planning. Phys Med Biol 1996, 41:111-124. 10.1088/0031-9155/41/1/009 8685250
    • (1996) Phys Med Biol , vol.41 , pp. 111-124
    • Schneider, U.1    Pedroni, E.2    Lomax, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.