Volumn 75, Issue 3, 2005, Pages 271.E1-271.E8

Cone-beam-CT guided radiation therapy: A model for on-line application

Author keywords

Cone beam CT; IGRT; Image guided therapy; On line imaging

Indexed keywords

ACCURACY; ANALYTICAL ERROR; ARTICLE; CANCER RADIOTHERAPY; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER ASSISTED TOMOGRAPHY; CONE BEAM COMPUTER ASSISTED TOMOGRAPHY GUIDED RADIATION THERAPY; IMAGE QUALITY; MACHINE; ONLINE MONITORING; PHANTOM; PRIORITY JOURNAL; PROSTATE CANCER; QUALITY CONTROL; RADIOSURGERY; SKULL; SOFT TISSUE; STATISTICAL SIGNIFICANCE; TREATMENT PLANNING;

EID: 22444451154     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2005.03.026     Document Type: Article
Times cited : (203)

References (29)
  • 1
    • 0037402518 scopus 로고    scopus 로고
    • Prediction of the benefits from dose-escalated hypofractionated intensity-modulated radiotherapy for prostate cancer
    • A.M. Amer, Mott, Mackay, Williams, Livsey, and Logue Prediction of the benefits from dose-escalated hypofractionated intensity-modulated radiotherapy for prostate cancer Int J Radiat Oncol Biol Phys 56 2003 199 207
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 199-207
    • Amer, A.M.1    Mott2    MacKay3    Williams4    Livsey5    Logue6
  • 2
    • 0142057570 scopus 로고    scopus 로고
    • Adapting inverse planning to patient and organ geometrical variation: Algorithm and implementation
    • M. Birkner, Yan, Alber, Liang, and Nusslin Adapting inverse planning to patient and organ geometrical variation: algorithm and implementation Med Phys 30 2003 2822 2831
    • (2003) Med Phys , vol.30 , pp. 2822-2831
    • Birkner, M.1    Yan2    Alber3    Liang4    Nusslin5
  • 3
    • 11144279948 scopus 로고    scopus 로고
    • Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy
    • K.E. Deurloo, Steenbakkers, Zijp, de Bois, Nowak, and Rasch van Herk Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy Int J Radiat Oncol Biol Phys 61 2005 228 238
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 228-238
    • Deurloo, K.E.1    Steenbakkers2    Zijp3    De Bois4    Nowak5    Van Herk, R.6
  • 4
    • 21044457706 scopus 로고    scopus 로고
    • Prostate gland motion assessed with cine-Magnetic-Resonance Imaging (cine-MR)
    • AD; in press:.
    • Ghilezan, M, Jaffray, Siewerdsen, van Herk, Shetty, Sharpe, et al. Prostate gland motion assessed with cine-Magnetic-Resonance Imaging (cine-MR). Int J Radiat Oncol Biol Phys 3 AD; in press:.
    • Int J Radiat Oncol Biol Phys , vol.3
    • Ghilezan, M.1    Jaffray2    Siewerdsen3    Van Herk4    Shetty5    Sharpe6
  • 6
    • 0035018405 scopus 로고    scopus 로고
    • Clinical use of electronic portal imaging: Report of AAPM radiation therapy committee task group 58
    • M.G. Herman, Balter, Jaffray, McGee, Munro, and Shalev Clinical use of electronic portal imaging: report of AAPM radiation therapy committee task group 58 Med Phys 28 2001 712 737
    • (2001) Med Phys , vol.28 , pp. 712-737
    • Herman, M.G.1    Balter2    Jaffray3    McGee4    Munro5    Shalev6
  • 7
    • 0028820553 scopus 로고
    • Dual-beam imaging for online verification of radiotherapy field placement
    • D.A. Jaffray, Chawla, and Yu Wong Dual-beam imaging for online verification of radiotherapy field placement Int J Radiat Oncol Biol Phys 33 1995 1273 1280
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1273-1280
    • Jaffray, D.A.1    Chawla2    Wong, Y.3
  • 8
    • 0032866087 scopus 로고    scopus 로고
    • A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
    • D.A. Jaffray, Drake, Moreau, Martinez, and Wong A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets Int J Radiat Oncol Biol Phys 45 1999 773 789
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 773-789
    • Jaffray, D.A.1    Drake2    Moreau3    Martinez4    Wong5
  • 9
    • 0034086714 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • D.A. Jaffray, and Siewerdsen Cone-beam computed tomography with a flat-panel imager: initial performance characterization Med Phys 27 2000 1311 1323
    • (2000) Med Phys , vol.27 , pp. 1311-1323
    • Jaffray, D.A.1    Siewerdsen2
  • 10
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • D.A. Jaffray, Siewerdsen, Siewerdsen, Wong, and Martinez Flat-panel cone-beam computed tomography for image-guided radiation therapy Int J Radiat Oncol Biol Phys 53 2002 1337 1349
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen2    Siewerdsen3    Wong4    Martinez5
  • 11
    • 0141504143 scopus 로고    scopus 로고
    • Evaluation of ultrasound-based prostate localization for image-guided radiotherapy
    • K.M. Langen, Pouliot, Anezinos, Aubin, Gottschalk, and Hsu III Evaluation of ultrasound-based prostate localization for image-guided radiotherapy Int J Radiat Oncol Biol Phys 57 2003 635 644
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 635-644
    • Langen, K.M.1    Pouliot2    Anezinos3    Aubin4    Gottschalk5    Hsu III6
  • 12
    • 0141504143 scopus 로고    scopus 로고
    • Evaluation of ultrasound-based prostate localization for image-guided radiotherapy
    • K.M. Langen, Pouliot, Anezinos, Aubin, Gottschalk, and Hsu III Evaluation of ultrasound-based prostate localization for image-guided radiotherapy Int J Radiat Oncol Biol Phys 57 2003 635 644
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 635-644
    • Langen, K.M.1    Pouliot2    Anezinos3    Aubin4    Gottschalk5    Hsu III6
  • 13
    • 0033062679 scopus 로고    scopus 로고
    • A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer
    • J. Lattanzi, McNeeley, Pinover, Horwitz, Das, and Schultheiss A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer Int J Radiat Oncol Biol Phys 43 1999 719 725
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 719-725
    • Lattanzi, J.1    McNeeley2    Pinover3    Horwitz4    Das5    Schultheiss6
  • 14
    • 32744474667 scopus 로고    scopus 로고
    • Cone-Beam-CT Guided Radiation Therapy, Part I: Clinical implementation
    • submitted Dec.
    • Letourneau, D, Oldham, Gulam, Yan, Wong. Cone-Beam-CT Guided Radiation Therapy, Part I: clinical implementation. Int J Radiat Oncol Biol Phys; 2003, submitted Dec.
    • (2003) Int J Radiat Oncol Biol Phys
    • Letourneau, D.1    Oldham2    Gulam3    Yan4    Wong5
  • 15
    • 14844289693 scopus 로고    scopus 로고
    • Implementation of an on-board kilovoltage cone-beam CT imaging system for clinical applications
    • D. Letourneau, Watt, Gulam, Oldham, and Wong Implementation of an on-board kilovoltage cone-beam CT imaging system for clinical applications Int J Radiat Oncol Biol Phys 57 2003 S185
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 185
    • Letourneau, D.1    Watt2    Gulam3    Oldham4    Wong5
  • 16
    • 0035424531 scopus 로고    scopus 로고
    • Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer
    • A.A. Martinez, Yan, Lockman, Brabbins, Kota, and Sharpe Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer Int J Radiat Oncol Biol Phys 50 2001 1226 1234
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 1226-1234
    • Martinez, A.A.1    Yan2    Lockman3    Brabbins4    Kota5    Sharpe6
  • 17
    • 0027508112 scopus 로고
    • An evaluation of two methods of anatomical alignment of radiotherapy portal images
    • J.M. Michalski, Bosch, Yan, Cheng, and Gerber An evaluation of two methods of anatomical alignment of radiotherapy portal images Int J Radiat Oncol Biol Phys 27 1993 1199 1206
    • (1993) Int J Radiat Oncol Biol Phys , vol.27 , pp. 1199-1206
    • Michalski, J.M.1    Bosch2    Yan3    Cheng4    Gerber5
  • 18
    • 0027370912 scopus 로고
    • The use of on-line image verification to estimate the variation in radiation therapy dose delivery
    • J.M. Michalski, Wong, Gerber, Yan, Cheng, and Graham The use of on-line image verification to estimate the variation in radiation therapy dose delivery Int J Radiat Oncol Biol Phys 27 1993 707 716
    • (1993) Int J Radiat Oncol Biol Phys , vol.27 , pp. 707-716
    • Michalski, J.M.1    Wong2    Gerber3    Yan4    Cheng5    Graham6
  • 20
    • 0034912917 scopus 로고    scopus 로고
    • High resolution gel-dosimetry by optical-CT and MR scanning
    • M. Oldham, Siewerdsen, Shetty, and Jaffray High resolution gel-dosimetry by optical-CT and MR scanning Med Phys 28 2001 1436 1445
    • (2001) Med Phys , vol.28 , pp. 1436-1445
    • Oldham, M.1    Siewerdsen2    Shetty3    Jaffray4
  • 21
    • 0032432269 scopus 로고    scopus 로고
    • A room-based diagnostic imaging system for measurement of patient setup
    • J.E. Schewe, Lam, Balter, and Ten Haken A room-based diagnostic imaging system for measurement of patient setup Med Phys 25 1998 2385 2387
    • (1998) Med Phys , vol.25 , pp. 2385-2387
    • Schewe, J.E.1    Lam2    Balter3    Haken, T.4
  • 22
    • 0035110308 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of X-ray scatter
    • J.H. Siewerdsen, and Jaffray Cone-beam computed tomography with a flat-panel imager: magnitude and effects of X-ray scatter Med Phys 28 2001 220 231
    • (2001) Med Phys , vol.28 , pp. 220-231
    • Siewerdsen, J.H.1    Jaffray2
  • 23
    • 0842306308 scopus 로고    scopus 로고
    • Errors and margins in radiotherapy
    • M. van Herk Errors and margins in radiotherapy Semin Radiat Oncol 14 2004 52 64
    • (2004) Semin Radiat Oncol , vol.14 , pp. 52-64
    • Van Herk, M.1
  • 24
    • 0344530449 scopus 로고    scopus 로고
    • IMRT: Delivery techniques and quality assurance
    • P.C. Williams IMRT: delivery techniques and quality assurance Br J Radiol 76 2003 766 776
    • (2003) Br J Radiol , vol.76 , pp. 766-776
    • Williams, P.C.1
  • 25
    • 0027330417 scopus 로고
    • On-line image verification in radiation therapy: An early USA experience
    • J.W. Wong, Gerber, Michalski, Graham, Halverson, and Cheng On-line image verification in radiation therapy: an early USA experience Med Prog Technol 19 1993 43 54
    • (1993) Med Prog Technol , vol.19 , pp. 43-54
    • Wong, J.W.1    Gerber2    Michalski3    Graham4    Halverson5    Cheng6
  • 26
    • 0034255946 scopus 로고    scopus 로고
    • An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer
    • D. Yan, Lockman, Brabbins, Tyburshi, and Martinez An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer Int J Radiat Oncol Biol Phys 48 2000 289 302
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 289-302
    • Yan, D.1    Lockman2    Brabbins3    Tyburshi4    Martinez5
  • 27
    • 0034255946 scopus 로고    scopus 로고
    • An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer
    • D. Yan, Lockman, Brabbins, Tyburshi, and Martinez An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer Int J Radiat Oncol Biol Phys 48 2000 289 302
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 289-302
    • Yan, D.1    Lockman2    Brabbins3    Tyburshi4    Martinez5
  • 28
    • 0035889319 scopus 로고    scopus 로고
    • The influence of interpatient and intrapatient rectum variation on external beam treatment of prostate cancer
    • D. Yan, Lockman, Kota, Brabbins, wong, and Martinez The influence of interpatient and intrapatient rectum variation on external beam treatment of prostate cancer Int J Radiat Oncol Biol Phys 51 2001 1111 1119
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1111-1119
    • Yan, D.1    Lockman2    Kota3    Brabbins4    Wong5    Martinez6
  • 29
    • 0035889319 scopus 로고    scopus 로고
    • The influence of interpatient and intrapatient rectum variation on external beam treatment of prostate cancer
    • D. Yan, Lockman, Kota, Brabbins, wong, and Martinez The influence of interpatient and intrapatient rectum variation on external beam treatment of prostate cancer Int J Radiat Oncol Biol Phys 51 2001 1111 1119
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1111-1119
    • Yan, D.1    Lockman2    Kota3    Brabbins4    Wong5    Martinez6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.