메뉴 건너뛰기




Volumn 44, Issue 1, 2009, Pages 121-130

Membrane fouling in the reclamation of secondary effluent with an ozone-membrane hybrid system

Author keywords

Ceramic membrane; Membrane fouling; Microfiltration; Ozonation; Secondary effluent

Indexed keywords

BACTERIOLOGY; CERAMIC MEMBRANES; CHROMATOGRAPHIC ANALYSIS; EFFLUENTS; ELECTRIC GROUNDING; HYBRID COMPUTERS; MICROFILTRATION; MOLECULES; OZONE; OZONIZATION;

EID: 61449242073     PISSN: 01496395     EISSN: 15205754     Source Type: Journal    
DOI: 10.1080/01496390802391171     Document Type: Article
Times cited : (8)

References (26)
  • 1
  • 2
    • 33746567170 scopus 로고    scopus 로고
    • Feasibility study for reclamation of a secondary treated sewage effluent mainly from industrial sources using a dual membrane process
    • Qin, J.J.; Wai, M.N.; Oo, M.H.; Kekre, K.A.; Seah, H. (2006) Feasibility study for reclamation of a secondary treated sewage effluent mainly from industrial sources using a dual membrane process. Sep. Purif. Techno!., 50: 380-387.
    • (2006) Sep. Purif. Techno!., 50 , pp. 380-387
    • Qin, J.J.1    Wai, M.N.2    Oo, M.H.3    Kekre, K.A.4    Seah, H.5
  • 3
    • 0032552615 scopus 로고    scopus 로고
    • Membranes enabling the affordable and cost effective reuse of wastewater as an alternative water source
    • Reith, C; Biikenhead, B. (1998) Membranes enabling the affordable and cost effective reuse of wastewater as an alternative water source. Desalination, 117: 203-209.
    • (1998) Desalination , vol.117 , pp. 203-209
    • Reith, C.1    Biikenhead, B.2
  • 4
    • 33751540748 scopus 로고    scopus 로고
    • Application of ultrafiltration hybrid membrane processes for reuse of secondary effluent
    • Lee, C.W.; Bae, S.D.; Han, S.W.; Kang, L.S. (2007) Application of ultrafiltration hybrid membrane processes for reuse of secondary effluent. Desalination, 202: 239-246.
    • (2007) Desalination , vol.202 , pp. 239-246
    • Lee, C.W.1    Bae, S.D.2    Han, S.W.3    Kang, L.S.4
  • 5
    • 37249044782 scopus 로고    scopus 로고
    • Degradation characteristics of secondary effluent of domestic wastewater by combined process of ozonation and biofiltration
    • Wang, S.; Ma, J.; Liu, B.; Jiang, Y.; Zhang, H. (2008) Degradation characteristics of secondary effluent of domestic wastewater by combined process of ozonation and biofiltration. J. Hazard. Mater., 150 (1): 109-114.
    • (2008) J. Hazard. Mater , vol.150 , Issue.1 , pp. 109-114
    • Wang, S.1    Ma, J.2    Liu, B.3    Jiang, Y.4    Zhang, H.5
  • 6
    • 24144465163 scopus 로고    scopus 로고
    • Methods employed for control of fouling in MF and UF membranes: A comprehensive review
    • Filial, N.; Ogunbiyi, O.O.; Miles, N.J.; Nigmarulin, R. (2005) Methods employed for control of fouling in MF and UF membranes: A comprehensive review. Sep. Sci. TechnoL, 40: 1957-2005.
    • (2005) Sep. Sci. TechnoL , vol.40 , pp. 1957-2005
    • Filial, N.1    Ogunbiyi, O.O.2    Miles, N.J.3    Nigmarulin, R.4
  • 7
    • 13444270404 scopus 로고    scopus 로고
    • Effect of residual ozone on membrane fouling reduction in ozone resisting microfiltration (MF) membrane system
    • Lee, S.; Jang, N.; Watanabe, Y. (2004) Effect of residual ozone on membrane fouling reduction in ozone resisting microfiltration (MF) membrane system. Water Sci. Technol, 50 (12): 287-292.
    • (2004) Water Sci. Technol , vol.50 , Issue.12 , pp. 287-292
    • Lee, S.1    Jang, N.2    Watanabe, Y.3
  • 8
    • 27644575697 scopus 로고    scopus 로고
    • Comparison of membrane permeability and a fouling mechanism by pre-ozonation followed by membrane filtration and residual ozone in membrane cells
    • Lee, S.; Lee, K.; Wan, M.W.; Yongsu, C. (2005) Comparison of membrane permeability and a fouling mechanism by pre-ozonation followed by membrane filtration and residual ozone in membrane cells. Desalination, 178: 287-294.
    • (2005) Desalination , vol.178 , pp. 287-294
    • Lee, S.1    Lee, K.2    Wan, M.W.3    Yongsu, C.4
  • 9
    • 61449099998 scopus 로고    scopus 로고
    • Effect of the ozone-pretreatment in microfiltration membrane process for wastewater reuse
    • Singapore
    • Moon, S.Y.; Aim, S.H.; Hong, S.W. (2006) Effect of the ozone-pretreatment in microfiltration membrane process for wastewater reuse. Proceedings of Membrane Science & Technology, Singapore.
    • (2006) Proceedings of Membrane Science & Technology
    • Moon, S.Y.1    Aim, S.H.2    Hong, S.W.3
  • 10
    • 0037057043 scopus 로고    scopus 로고
    • Desalination, 147:
    • 43-4-8
    • Park, Y.G. (2002) Effect of ozonation for reducing membrane-fouling in the UF membrane. Desalination, 147: 43-4-8.
    • (2002)
    • Park, Y.G.1
  • 11
    • 33846862671 scopus 로고    scopus 로고
    • Role of ozone for reducing fouling due to pharmaceuticals in MF (microfiltration) process
    • Oh, B.S.; Jang, H.Y.; Hwang, T.M.; Kang, J.W. (2007) Role of ozone for reducing fouling due to pharmaceuticals in MF (microfiltration) process. J. Membr. Sci.,289: 178-186.
    • (2007) J. Membr. Sci , vol.289 , pp. 178-186
    • Oh, B.S.1    Jang, H.Y.2    Hwang, T.M.3    Kang, J.W.4
  • 12
    • 33845446740 scopus 로고    scopus 로고
    • Ozonation pretreatment for ultrafiltration of the secondary effluent
    • Wang, X.; Wang, L.; Liu, Y.; Duan, W. (2007) Ozonation pretreatment for ultrafiltration of the secondary effluent. J. Membr. Sci., 287: 187-191.
    • (2007) J. Membr. Sci , vol.287 , pp. 187-191
    • Wang, X.1    Wang, L.2    Liu, Y.3    Duan, W.4
  • 13
    • 39149143326 scopus 로고    scopus 로고
    • Effect of ozone dosage and hydrodynamic conditions on the permeate flux in a hybrid ozonation-ceramic ultrafiltration system treating natural waters
    • Kim, J.; Davies, S.H.R.; Baumann, M.J.; Tarabara, V.V.; Masten, S.J. (2008) Effect of ozone dosage and hydrodynamic conditions on the permeate flux in a hybrid ozonation-ceramic ultrafiltration system treating natural waters. / Membr. Sci., 311: 165-172.
    • (2008) Membr. Sci , vol.311 , pp. 165-172
    • Kim, J.1    Davies, S.H.R.2    Baumann, M.J.3    Tarabara, V.V.4    Masten, S.J.5
  • 14
    • 33744979769 scopus 로고    scopus 로고
    • Irreversible fouling in MF/UF membranes caused by natural organic matters (NOMs) isolated from different origins
    • Kimura, K.; Yamamura, H.; Watanabe, Y. (2006) Irreversible fouling in MF/UF membranes caused by natural organic matters (NOMs) isolated from different origins. Sep. Sci. Technol., 41, 1331-1344.
    • (2006) Sep. Sci. Technol , vol.41 , pp. 1331-1344
    • Kimura, K.1    Yamamura, H.2    Watanabe, Y.3
  • 15
    • 34250160194 scopus 로고    scopus 로고
    • Potential ozone applications for water/wastewater treatment
    • Zouboulis, A.; Samaras, P.; Ntampou, X.; Petala, M. (2007) Potential ozone applications for water/wastewater treatment. Sep. Sci. Technol., 42: 1433-1446.
    • (2007) Sep. Sci. Technol , vol.42 , pp. 1433-1446
    • Zouboulis, A.1    Samaras, P.2    Ntampou, X.3    Petala, M.4
  • 16
    • 0031986168 scopus 로고    scopus 로고
    • Effects of NOM source variations and calcium complexation capacity on ozone-induced particle destabilization
    • Chandrakanth, M.S.; Amy, G.L. (1998) Effects of NOM source variations and calcium complexation capacity on ozone-induced particle destabilization. Water Res., 32 (I): 115-124.
    • (1998) Water Res , vol.32 , Issue.I , pp. 115-124
    • Chandrakanth, M.S.1    Amy, G.L.2
  • 17
    • 33750373676 scopus 로고    scopus 로고
    • Jansen, R.H.S.; Zwijnenburg, A.; Van der meer, W.G.J.; Wessling, M. (2006) Outside-in trimming of humic substances during ozonation in a membrane contactor. Environ. Sci. Technol., 40: 6460-6465.
    • Jansen, R.H.S.; Zwijnenburg, A.; Van der meer, W.G.J.; Wessling, M. (2006) Outside-in trimming of humic substances during ozonation in a membrane contactor. Environ. Sci. Technol., 40: 6460-6465.
  • 18
    • 20444446025 scopus 로고    scopus 로고
    • Hollow fiber membrane contactors-A means to study the reaction kinetics of humic substance ozonation
    • Jansen, R.H.S.; Rijk, R.J.W.d.; Zwijnenburg, A.; Mulder, M.H.V.; Wessling, M. (2005) Hollow fiber membrane contactors-A means to study the reaction kinetics of humic substance ozonation. J. Membr. Sci., 257:48-59.
    • (2005) J. Membr. Sci , vol.257 , pp. 48-59
    • Jansen, R.H.S.1    Rijk, R.J.W.D.2    Zwijnenburg, A.3    Mulder, M.H.V.4    Wessling, M.5
  • 20
    • 0036877178 scopus 로고    scopus 로고
    • State of the art-review: Ozonation of municipal wastewater effluents
    • Paraskeva, P.; Graham, N.J.D. (2002) State of the art-review: Ozonation of municipal wastewater effluents. Water Environ. Res., 74 (6): 569-581.
    • (2002) Water Environ. Res , vol.74 , Issue.6 , pp. 569-581
    • Paraskeva, P.1    Graham, N.J.D.2
  • 21
    • 0032948166 scopus 로고    scopus 로고
    • Chlorination and ozonation of waste-water: Comparative analysis of efficacy through the effect on Escherichia coli membranes
    • Arana, I.; Santorum, P.; Muela, A.; Barcina, I. (1999) Chlorination and ozonation of waste-water: comparative analysis of efficacy through the effect on Escherichia coli membranes. J. Appl Microbial, 86: 883-888.
    • (1999) J. Appl Microbial , vol.86 , pp. 883-888
    • Arana, I.1    Santorum, P.2    Muela, A.3    Barcina, I.4
  • 22
    • 37349049489 scopus 로고    scopus 로고
    • The study on bactericidal mechanism of plasmas ozone against E.coli on the surface
    • in Chinese
    • Gu, C; Xue, G.; Ju, X. (2004) The study on bactericidal mechanism of plasmas ozone against E.coli on the surface. Modern Preventive Medicine, 31 (1): 33-35. (in Chinese)
    • (2004) Modern Preventive Medicine , vol.31 , Issue.1 , pp. 33-35
    • Gu, C.1    Xue, G.2    Ju, X.3
  • 23
    • 3042808855 scopus 로고    scopus 로고
    • Electron microscopic investigation of the bactericidal action of electrochemical disinfection in comparison with chlorination, ozonation and Fenton reaction
    • Diao, H.F.; Li, X.Y.; Gu, J.D. (2004) Electron microscopic investigation of the bactericidal action of electrochemical disinfection in comparison with chlorination, ozonation and Fenton reaction. Process Biochemistry, 39: 1421-1426.
    • (2004) Process Biochemistry , vol.39 , pp. 1421-1426
    • Diao, H.F.1    Li, X.Y.2    Gu, J.D.3
  • 25
    • 0037056707 scopus 로고    scopus 로고
    • Fouling characteristics of wastewater effluent organic matter (EfOM) isolates on NF and UF membranes
    • Jarusutthirak, C; Amy, G.; Croúe, J.-P. (2002) Fouling characteristics of wastewater effluent organic matter (EfOM) isolates on NF and UF membranes. Desalination, 145: 247-255.
    • (2002) Desalination , vol.145 , pp. 247-255
    • Jarusutthirak, C.1    Amy, G.2    Croúe, J.-P.3
  • 26
    • 0041430724 scopus 로고    scopus 로고
    • Characterization of DOM as a function of MW by fluorescence EEM and HPLC-SEC using UVA, DOC, and fluorescence detection
    • Her, K; Amy, G.; McKnight, D.; Sohn, J.; Yoon, Y. (2003) Characterization of DOM as a function of MW by fluorescence EEM and HPLC-SEC using UVA, DOC, and fluorescence detection. Water Research, 37 (17): 4295-4303.
    • (2003) Water Research , vol.37 , Issue.17 , pp. 4295-4303
    • Her, K.1    Amy, G.2    McKnight, D.3    Sohn, J.4    Yoon, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.