메뉴 건너뛰기




Volumn 36, Issue 3, 2009, Pages 684-697

Radiotherapy margin design with particular consideration of high curvature CTVs

Author keywords

Conformal radiotherapy; IMRT; Margins; Prostate; Radiotherapy; Setup errors

Indexed keywords

ERRORS; HIGH ENERGY PHYSICS;

EID: 61349157876     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3070539     Document Type: Article
Times cited : (2)

References (23)
  • 1
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • M. van Herk, P. Remeijer, C. Rasch, and J. V. Lebesque, " The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. 47 (4), 1121-1135 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.47 , Issue.4 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 2
    • 0003418877 scopus 로고    scopus 로고
    • International Commission on Radiation Units and Measurements ICRU Report No. 50.
    • " Prescribing, recording, and reporting photon beam therapy.," International Commission on Radiation Units and Measurements ICRU Report No. 50, 1994.
    • (1994) Prescribing, Recording, and Reporting Photon Beam Therapy
  • 3
    • 0003418877 scopus 로고    scopus 로고
    • International Commission on Radiation Units and Measurements ICRU Report No. 62.
    • " Prescribing, recording, and reporting photon beam therapy.," International Commission on Radiation Units and Measurements ICRU Report No. 62, 2000.
    • (2000) Prescribing, Recording, and Reporting Photon Beam Therapy
  • 4
    • 0842306308 scopus 로고    scopus 로고
    • Errors and margins in radiotherapy
    • M. van Herk, " Errors and margins in radiotherapy.," Semin. Radiat. Oncol. 14 (1), 52-64 (2004).
    • (2004) Semin. Radiat. Oncol. , vol.14 , Issue.1 , pp. 52-64
    • Van Herk, M.1
  • 5
    • 33845917236 scopus 로고    scopus 로고
    • Evaluation of clinical margins via simulation of patient setup errors in prostate IMRT treatment plans
    • J. J. Gordon, A. J. Crimaldi, M. Hagan, J. Moore, and J. V. Siebers, " Evaluation of clinical margins via simulation of patient setup errors in prostate IMRT treatment plans.," Med. Phys. 34, 202-214 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 202-214
    • Gordon, J.J.1    Crimaldi, A.J.2    Hagan, M.3    Moore, J.4    Siebers, J.V.5
  • 6
    • 0029810297 scopus 로고    scopus 로고
    • Target margins for random geometrical treatment uncertainties in conformal radiotherapy
    • A. Bel, M. van Herk, and J. V. Lebesque, " Target margins for random geometrical treatment uncertainties in conformal radiotherapy.," Med. Phys. 23, 1537-1545 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1537-1545
    • Bel, A.1    Van Herk, M.2    Lebesque, J.V.3
  • 7
    • 0036661305 scopus 로고    scopus 로고
    • Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report
    • J. C. Stroom and B. J. Heijmen, " Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report.," Radiother. Oncol. 64 (1), 75-83 (2002).
    • (2002) Radiother. Oncol. , vol.64 , Issue.1 , pp. 75-83
    • Stroom, J.C.1    Heijmen, B.J.2
  • 8
    • 0036534905 scopus 로고    scopus 로고
    • Inclusion of geometric uncertainties in treatment plan evaluation
    • M. van Herk, P. Remeijer, and J. V. Lebesque, " Inclusion of geometric uncertainties in treatment plan evaluation.," Int. J. Radiat. Oncol., Biol., Phys. 52 (5), 1407-1422 (2002).
    • (2002) Int. J. Radiat. Oncol., Biol., Phys. , vol.52 , Issue.5 , pp. 1407-1422
    • Van Herk, M.1    Remeijer, P.2    Lebesque, J.V.3
  • 9
    • 0033773907 scopus 로고    scopus 로고
    • The width of margins in radiotherapy treatment plans
    • A. L. McKenzie, M. van Herk, and B. Mijnheer, " The width of margins in radiotherapy treatment plans.," Phys. Med. Biol. 45, 3331-3342 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3331-3342
    • McKenzie, A.L.1    Van Herk, M.2    Mijnheer, B.3
  • 10
    • 0033041247 scopus 로고    scopus 로고
    • Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability
    • J. C. Stroom, H. C. J. de Boer, H. Huizenga, and A. G. Visser, " Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability.," Int. J. Radiat. Oncol., Biol., Phys. 43 (4), 905-919 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.43 , Issue.4 , pp. 905-919
    • Stroom, J.C.1    De Boer, H.C.J.2    Huizenga, H.3    Visser, A.G.4
  • 11
    • 0036603749 scopus 로고    scopus 로고
    • Margins for translational and rotational uncertainties: A probability-based approach
    • P. Remeijer, C. Rasch, J. V. Lebesque, and M. van Herk, " Margins for translational and rotational uncertainties: A probability-based approach.," Int. J. Radiat. Oncol., Biol., Phys. 53 (1), 464-474 (2002).
    • (2002) Int. J. Radiat. Oncol., Biol., Phys. , vol.53 , Issue.1 , pp. 464-474
    • Remeijer, P.1    Rasch, C.2    Lebesque, J.V.3    Van Herk, M.4
  • 13
    • 34547551811 scopus 로고    scopus 로고
    • Lung cancer: A model for implementing stereotactic body radiation therapy into practice
    • R. D. Timmerman, R. Abdulrahman, B. D. Kavanagh, and J. L. Meyer, " Lung cancer: A model for implementing stereotactic body radiation therapy into practice.," Front. Radiat. Ther. Oncol. 40, 368-85 (2007).
    • (2007) Front. Radiat. Ther. Oncol. , vol.40 , pp. 368-385
    • Timmerman, R.D.1    Abdulrahman, R.2    Kavanagh, B.D.3    Meyer, J.L.4
  • 14
    • 50949087406 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: Radiation therapy
    • L. A. Dawson and C. Guha, " Hepatocellular carcinoma: Radiation therapy.," Cancer J. 14 (2), 111-116 (2008).
    • (2008) Cancer J. , vol.14 , Issue.2 , pp. 111-116
    • Dawson, L.A.1    Guha, C.2
  • 16
    • 9244219608 scopus 로고    scopus 로고
    • The effects of target size and tissue density on the minimum margin required for random errors
    • M. G. Witte, J. van der Geer, C. Schneider, J. V. Lebesque, and M. van Herk, " The effects of target size and tissue density on the minimum margin required for random errors.," Med. Phys. 31, 3068-3079 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 3068-3079
    • Witte, M.G.1    Van Der Geer, J.2    Schneider, C.3    Lebesque, J.V.4    Van Herk, M.5
  • 19
    • 35648991372 scopus 로고    scopus 로고
    • Stereotactic radiotherapy for stage I non small cell lung cancer-the triumph of technology over biology
    • D. Ball and R. Withers, " Stereotactic radiotherapy for stage I non small cell lung cancer-the triumph of technology over biology.," Viewpoint. Nature Clin. Pract. Oncol. 11, 614-615 (2007).
    • (2007) Viewpoint. Nature Clin. Pract. Oncol. , vol.11 , pp. 614-615
    • Ball, D.1    Withers, R.2
  • 20
    • 33947498981 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy in multiple organ sites
    • R. D. Timmerman, B. Kavanagh, C. Cho, L. Papier, and L. Xing, " Stereotactic body radiation therapy in multiple organ sites.," J. Clin. Oncol. 25, 947-952 (2007).
    • (2007) J. Clin. Oncol. , vol.25 , pp. 947-952
    • Timmerman, R.D.1    Kavanagh, B.2    Cho, C.3    Papier, L.4    Xing, L.5
  • 21
    • 21244477043 scopus 로고    scopus 로고
    • Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control
    • L. A. Dawson, C. Eccles, J. P. Bissonnette, and K. K. Brock, " Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control.," Int. J. Radiat. Oncol., Biol., Phys. 62 (4), 1247-1252 (2005).
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.62 , Issue.4 , pp. 1247-1252
    • Dawson, L.A.1    Eccles, C.2    Bissonnette, J.P.3    Brock, K.K.4
  • 23
    • 33947260025 scopus 로고    scopus 로고
    • Target volume definition for 18F-FDG PET-positive lymph nodes in radiotherapy of patients with non-small cell lung cancer
    • U. Nestle, A. Schaefer-Schuler, S. Kremp, A. Groeschel, D. Hellwig, C. Rübe, and C. M. Kirsch, " Target volume definition for 18F-FDG PET-positive lymph nodes in radiotherapy of patients with non-small cell lung cancer.," Eur. J. Nucl. Med. Mol. Imaging 34 (4), 453-462 (2007).
    • (2007) Eur. J. Nucl. Med. Mol. Imaging , vol.34 , Issue.4 , pp. 453-462
    • Nestle, U.1    Schaefer-Schuler, A.2    Kremp, S.3    Groeschel, A.4    Hellwig, D.5    Rübe, C.6    Kirsch, C.M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.