메뉴 건너뛰기




Volumn 53, Issue 10, 2009, Pages 872-880

The DAVID (Dual Chamber and VVI Implantable Defibrillator) II Trial

Author keywords

heart failure; implantable defibrillator; pacing

Indexed keywords

ANTIARRHYTHMIC AGENT; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; DIGITALIS; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; DIURETIC AGENT; HYDROXYMETHYLGLUTARYL COENZYME A REDUCTASE INHIBITOR; SPIRONOLACTONE;

EID: 60949106339     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2008.10.057     Document Type: Article
Times cited : (86)

References (20)
  • 1
    • 0037176263 scopus 로고    scopus 로고
    • Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator
    • DAVID Trial Investigators
    • DAVID Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator. JAMA 288 (2002) 3115-3123
    • (2002) JAMA , vol.288 , pp. 3115-3123
  • 2
    • 34548513084 scopus 로고    scopus 로고
    • Speckle-tracking radial strain reveals left ventricular dyssynchrony in patients with permanent right ventricular pacing
    • Tops L.F., Suffoletto M.S., Bleeker G.B., et al. Speckle-tracking radial strain reveals left ventricular dyssynchrony in patients with permanent right ventricular pacing. J Am Coll Cardiol 50 (2007) 1180-1188
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1180-1188
    • Tops, L.F.1    Suffoletto, M.S.2    Bleeker, G.B.3
  • 3
    • 0036263575 scopus 로고    scopus 로고
    • Difference in mechanical atrioventricular delay between atrial sensing and atrial pacing modes in patients with hypertrophic and dilated cardiomyopathy
    • Cha Y.M., Nishimura R.A., and Hayes D.L. Difference in mechanical atrioventricular delay between atrial sensing and atrial pacing modes in patients with hypertrophic and dilated cardiomyopathy. J Interv Card Electrophysiol 6 (2002) 133-140
    • (2002) J Interv Card Electrophysiol , vol.6 , pp. 133-140
    • Cha, Y.M.1    Nishimura, R.A.2    Hayes, D.L.3
  • 4
    • 55249096542 scopus 로고    scopus 로고
    • Effect of pacing for soft indications on mortality and heart failure in the Dual Chamber and VVI Implantable Defibrillator (DAVID) trial
    • Kutalek S.P., Sharma A.D., McWilliams M.J., et al. Effect of pacing for soft indications on mortality and heart failure in the Dual Chamber and VVI Implantable Defibrillator (DAVID) trial. Pacing Clin Electrophysiol 31 (2008) 828-837
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 828-837
    • Kutalek, S.P.1    Sharma, A.D.2    McWilliams, M.J.3
  • 5
    • 0033253481 scopus 로고    scopus 로고
    • HFSA guidelines for management of patients with heart failure caused by left ventricular systolic dysfunction
    • Heart Failure Society of America (HFSA) Practice Guidelines
    • Heart Failure Society of America (HFSA) Practice Guidelines. HFSA guidelines for management of patients with heart failure caused by left ventricular systolic dysfunction. J Card Fail 5 (1999) 357-382
    • (1999) J Card Fail , vol.5 , pp. 357-382
  • 6
    • 0000443786 scopus 로고
    • The MOS 36-Item Short-Form Health Survey (SF-36)
    • Ware Jr. J.E., and Sherbourne C.D. The MOS 36-Item Short-Form Health Survey (SF-36). Med Care 30 (1992) 4730-4783
    • (1992) Med Care , vol.30 , pp. 4730-4783
    • Ware Jr., J.E.1    Sherbourne, C.D.2
  • 7
    • 0003408447 scopus 로고
    • Ware J.E., Snow K.K., Kosinski M., and Gandek B. (Eds), Health Institute, New England Medical Center, Boston, MA
    • In: Ware J.E., Snow K.K., Kosinski M., and Gandek B. (Eds). SF-36 Health Survey (1993), Health Institute, New England Medical Center, Boston, MA
    • (1993) SF-36 Health Survey
  • 8
    • 7144256237 scopus 로고    scopus 로고
    • Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual chamber pacing
    • Lamas G.A., Oray J.E., Stambler B.S., et al. Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual chamber pacing. N Engl J Med 338 (1998) 1097-1104
    • (1998) N Engl J Med , vol.338 , pp. 1097-1104
    • Lamas, G.A.1    Oray, J.E.2    Stambler, B.S.3
  • 9
    • 0000110087 scopus 로고
    • Patients self-assessment of their congestive heart failure: content, reliability and validity of a new measure, the Minnesota Living with Heart Failure Questionnaire
    • Rector T.S., Kubo S.H., and Cohn J.N. Patients self-assessment of their congestive heart failure: content, reliability and validity of a new measure, the Minnesota Living with Heart Failure Questionnaire. Heart Failure 3 (1987) 198-209
    • (1987) Heart Failure , vol.3 , pp. 198-209
    • Rector, T.S.1    Kubo, S.H.2    Cohn, J.N.3
  • 10
    • 0026567057 scopus 로고
    • Beneficial effects of pimobendan on exercise tolerance and quality of life in patients with heart failure
    • Kubo S.H., Gollub S., Bourge R., et al. Beneficial effects of pimobendan on exercise tolerance and quality of life in patients with heart failure. Circulation 85 (1992) 942-949
    • (1992) Circulation , vol.85 , pp. 942-949
    • Kubo, S.H.1    Gollub, S.2    Bourge, R.3
  • 11
    • 0002524624 scopus 로고
    • Can simple questions assess outcome after stroke?
    • Lindley R.I., Waddell F., Livingstone M., et al. Can simple questions assess outcome after stroke?. Cerebrovasc Dis 4 (1994) 314-324
    • (1994) Cerebrovasc Dis , vol.4 , pp. 314-324
    • Lindley, R.I.1    Waddell, F.2    Livingstone, M.3
  • 13
    • 0031586473 scopus 로고    scopus 로고
    • Long term follow-up of patients from a randomized trial of atrial versus ventricular pacing for sick sinus syndrome
    • Andersen H.R., Nielsen J.C., Thomsen P.E., et al. Long term follow-up of patients from a randomized trial of atrial versus ventricular pacing for sick sinus syndrome. Lancet 350 (1997) 1210-1216
    • (1997) Lancet , vol.350 , pp. 1210-1216
    • Andersen, H.R.1    Nielsen, J.C.2    Thomsen, P.E.3
  • 14
    • 36849091068 scopus 로고    scopus 로고
    • Right atrial pacing and the risk of postimplant atrial fibrillation in cardiac resynchronization therapy recipients
    • Adelstein E., and Saba S. Right atrial pacing and the risk of postimplant atrial fibrillation in cardiac resynchronization therapy recipients. Am Heart J 155 (2008) 94-99
    • (2008) Am Heart J , vol.155 , pp. 94-99
    • Adelstein, E.1    Saba, S.2
  • 15
    • 0006918490 scopus 로고    scopus 로고
    • Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia
    • Multicenter Automatic Defibrillator Implantation Trial Investigators
    • Multicenter Automatic Defibrillator Implantation Trial Investigators. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. N Engl J Med 335 (1996) 1933-1940
    • (1996) N Engl J Med , vol.335 , pp. 1933-1940
  • 16
    • 0033576804 scopus 로고    scopus 로고
    • A randomized study of the prevention of sudden death in patients with coronary artery disease
    • Multicenter Unsustained Tachycardia Trial Investigators
    • Multicenter Unsustained Tachycardia Trial Investigators. A randomized study of the prevention of sudden death in patients with coronary artery disease. N Engl J Med 341 (1999) 1882-1890
    • (1999) N Engl J Med , vol.341 , pp. 1882-1890
  • 17
    • 0037149716 scopus 로고    scopus 로고
    • Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Multicenter Automatic Defibrillator Implantation Trial II Investigators
    • Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 346 (2002) 877-883
    • (2002) N Engl J Med , vol.346 , pp. 877-883
  • 18
    • 22744443121 scopus 로고    scopus 로고
    • Percent right ventricular pacing predicts outcomes in the DAVID trial
    • Sharma A.D., Rizzo-Patron C., Hallstrom A.P., et al. Percent right ventricular pacing predicts outcomes in the DAVID trial. Heart Rhythm 2 (2005) 830-834
    • (2005) Heart Rhythm , vol.2 , pp. 830-834
    • Sharma, A.D.1    Rizzo-Patron, C.2    Hallstrom, A.P.3
  • 19
    • 20144387118 scopus 로고    scopus 로고
    • The clinical implications of cumulative right ventricular pacing in the Multicenter Automatic Defibrillator Trial II
    • Steinberg J.S., Fischer A., Wang P., et al. The clinical implications of cumulative right ventricular pacing in the Multicenter Automatic Defibrillator Trial II. J Cardiovasc Electrophysiol 16 (2005) 359-365
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 359-365
    • Steinberg, J.S.1    Fischer, A.2    Wang, P.3
  • 20
    • 33846036283 scopus 로고    scopus 로고
    • Is dual-chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator
    • Olshansky B., Day J.D., Moore S., et al. Is dual-chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator. Circulation 115 (2007) 9-16
    • (2007) Circulation , vol.115 , pp. 9-16
    • Olshansky, B.1    Day, J.D.2    Moore, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.