-
1
-
-
0033008912
-
Detection failures in spiral CT screening for lung cancer: Analysis of CT findings
-
R. Kakinuma, H. Ohmatsu, and M. Kaneko, "Detection failures in spiral CT screening for lung cancer: Analysis of CT findings." Radiology 212, pp. 61-66, 1999.
-
(1999)
Radiology
, vol.212
, pp. 61-66
-
-
Kakinuma, R.1
Ohmatsu, H.2
Kaneko, M.3
-
2
-
-
0036892529
-
Lung cancers missed at low-dose helical CT screening in a general population: Comparison of clinical, histopathologic, and imaging findings
-
F. Li, S. Sone, H. Abe, H. MacMAhon, S. Armato III, and K. Doi, "Lung cancers missed at low-dose helical CT screening in a general population: Comparison of clinical, histopathologic, and imaging findings." Radiology 225, pp. 673-683, 2002.
-
(2002)
Radiology
, vol.225
, pp. 673-683
-
-
Li, F.1
Sone, S.2
Abe, H.3
MacMAhon, H.4
Armato III, S.5
Doi, K.6
-
3
-
-
0036999660
-
Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysis
-
Dec
-
Y. Masutani, H. MacMahon, and K. Doi, "Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysis," IEEE Trans. Med. Imag., vol. 21, no. 12, pp. 517-1523, Dec. 2002.
-
(2002)
IEEE Trans. Med. Imag
, vol.21
, Issue.12
, pp. 517-1523
-
-
Masutani, Y.1
MacMahon, H.2
Doi, K.3
-
4
-
-
5644273931
-
Regulated morphology approach to fuzzy shape analysis with application to blood vessel extraction in thoracic CT scans
-
C. Wu, G. Agam, A. S. Roy, and S. G. Armato, "Regulated morphology approach to fuzzy shape analysis with application to blood vessel extraction in thoracic CT scans," Proc. SPIE, vol. 5370, pp. 1262-1270, 2004.
-
(2004)
Proc. SPIE
, vol.5370
, pp. 1262-1270
-
-
Wu, C.1
Agam, G.2
Roy, A.S.3
Armato, S.G.4
-
5
-
-
5644304356
-
Analysis of arterial subtrees affected by pulmonary emboli
-
A. P. Kiraly, E. Pichon, D. P. Naidich, and C. L. Novak, "Analysis of arterial subtrees affected by pulmonary emboli," Proc. SPIE, vol. 5370, pp. 1720-1729, 2004.
-
(2004)
Proc. SPIE
, vol.5370
, pp. 1720-1729
-
-
Kiraly, A.P.1
Pichon, E.2
Naidich, D.P.3
Novak, C.L.4
-
6
-
-
11144266674
-
Knowledge-Based 3D Segmentation and Reconstruction of Coronary Arteries Using CT Images
-
Sep
-
Y. Yang, A. Tannembaum & D. Giddens, "Knowledge-Based 3D Segmentation and Reconstruction of Coronary Arteries Using CT Images," Proc. IEEE EMBS., pp. 1664-1666, Sep. 2004.
-
(2004)
Proc. IEEE EMBS
, pp. 1664-1666
-
-
Yang, Y.1
Tannembaum, A.2
Giddens, D.3
-
7
-
-
0018306059
-
A Threshold Selection Method from Gray-Level Histograms
-
Otsu, N., "A Threshold Selection Method from Gray-Level Histograms," IEEE Transactions on Systems, Man, and Cybernetics, vol. 9, no. 1, 1979, pp. 62-66.
-
(1979)
IEEE Transactions on Systems, Man, and Cybernetics
, vol.9
, Issue.1
, pp. 62-66
-
-
Otsu, N.1
-
8
-
-
0022808786
-
A Computational Approach to Edge Detection
-
Nov
-
Canny, J., "A Computational Approach to Edge Detection, IEEE Trans. on Pattern Analysis and Machine Intelligence", vol. PAMI-8, no. 6, Nov. 1986, pp. 679-698.
-
(1986)
IEEE Trans. on Pattern Analysis and Machine Intelligence
, vol.PAMI-8
, Issue.6
, pp. 679-698
-
-
Canny, J.1
-
9
-
-
60749090844
-
-
American College of Radiology, National Electrical Manufacturers Association, Digital Imaging and Communications in Medicine DICOM, Version 3.0, Draft Standard, ACR-NEMA Committee, Working Group VI, Washington, DC, 1993
-
American College of Radiology, National Electrical Manufacturers Association, "Digital Imaging and Communications in Medicine (DICOM): Version 3.0", Draft Standard, ACR-NEMA Committee, Working Group VI, Washington, DC, 1993.
-
-
-
-
11
-
-
84971372881
-
Marching Cubes: A High Resolution 3D Surface Construction Algorithm
-
87, 21
-
William E. Lorensen and Harvey E. Cline, "Marching Cubes: A High Resolution 3D Surface Construction Algorithm", Computer Graphics (Proceedings of SIGGRAPH '87), vol. 21, no. 4, pp. 163-169, 1998.
-
(1998)
Computer Graphics (Proceedings of SIGGRAPH
, Issue.4
, pp. 163-169
-
-
Lorensen, W.E.1
Cline, H.E.2
|