Volumn 21, Issue 12, 2002, Pages 1517-1523

Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysis

Author keywords

Computer aided diagnosis; Pulmonary embolism; Segmentation; Volumetric image analysis

Indexed keywords

ANGIOGRAPHY; COMPUTER AIDED DIAGNOSIS; COMPUTERIZED TOMOGRAPHY; IMAGE ANALYSIS; IMAGE SEGMENTATION; INTERPOLATION; MATHEMATICAL MORPHOLOGY; PULMONARY DISEASES; RESPIRATORY THERAPY;

EID: 0036999660     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2002.806586     Document Type: Article
Times cited : (136)

References (13)
  • 1
    • 0013403538 scopus 로고    scopus 로고
    • M. Remy-Jardin, Ed.; Berlin, Germany: Springer-Verlag
    • M. Remy-Jardin, Ed., Spiral CT of the Chest (Medical Radiology). Berlin, Germany: Springer-Verlag, 1996.
    • (1996) Spiral CT of the Chest (Medical Radiology)
  • 2
    • 0031723153 scopus 로고    scopus 로고
    • Pitfalls in diagnosis of pulmonary embolism with helical CT angiography
    • Sept.
    • C. Beigelman, C. Chartrand-Lefebvre, N. Howarth, and P. Grenier, "Pitfalls in diagnosis of pulmonary embolism with helical CT angiography," Amer. J. Radiol., vol. 171, pp. 579-585, Sept. 1998.
    • (1998) Amer. J. Radiol. , vol.171 , pp. 579-585
    • Beigelman, C.1    Chartrand-Lefebvre, C.2    Howarth, N.3    Grenier, P.4
  • 3
    • 0002994238 scopus 로고    scopus 로고
    • Morphometric methods for virtual endoscopy reconstructions
    • I.N. Bankman, Ed. New York: Academic; ch. 45
    • R. M. Summers, "Morphometric methods for virtual endoscopy reconstructions," in Handbook of Medical Imaging: Processing and Analysis, I.N. Bankman, Ed. New York: Academic, 2000, ch. 45, pp. 747-755.
    • (2000) Handbook of Medical Imaging: Processing and Analysis , pp. 747-755
    • Summers, R.M.1
  • 4
    • 0033705299 scopus 로고    scopus 로고
    • Computer-assisted detection of pulmonary embolism
    • Y. Masutani, H. McMahon, and K. Doi, "Computer-assisted detection of pulmonary embolism," Proc. SPIE (Medical Imaging 2000), pt. II, vol. 3979, pp. 944-950.
    • Proc. SPIE (Medical Imaging 2000) , vol.3979 , Issue.PART 2 , pp. 944-950
    • Masutani, Y.1    McMahon, H.2    Doi, K.3
  • 5
    • 0013364458 scopus 로고    scopus 로고
    • Computerized detection of pulmonary embolism in spiral CT angiography: A segmentation-based approach using 3D image analysis and anatomical knowledge
    • H. U. Lemke, M. W. Vannier, K. Inamura, A. G. Farman, and K. Doi, Eds.
    • ____, "Computerized detection of pulmonary embolism in spiral CT angiography: A segmentation-based approach using 3D image analysis and anatomical knowledge," in Proc. Computer-Assisted Radiology and Surgery, H. U. Lemke, M. W. Vannier, K. Inamura, A. G. Farman, and K. Doi, Eds., 2000, pp. 779-784.
    • (2000) Proc. Computer-Assisted Radiology and Surgery , pp. 779-784
    • Masutani, Y.1    MacMahon, H.2    Doi, K.3
  • 6
    • 0000021761 scopus 로고    scopus 로고
    • Automated segmentation of the pulmonary vascular tree in spiral CT angiography for computerized detection of pulmonary embolism
    • ____, "Automated segmentation of the pulmonary vascular tree in spiral CT angiography for computerized detection of pulmonary embolism," in Med. Phys. 26 (AAPM Annu. Meeting Issue), 1999, p. 1101.
    • Med. Phys. 26 (AAPM Annu. Meeting Issue), 1999 , pp. 1101
    • Masutani, Y.1    MacMahon, H.2    Doi, K.3
  • 7
    • 0022773971 scopus 로고
    • Grayscale morphology
    • S. R. Sternberg, "Grayscale morphology," CVGIP, vol. 35, no. 3, pp. 333-355, 1986.
    • (1986) CVGIP , vol.35 , Issue.3 , pp. 333-355
    • Sternberg, S.R.1
  • 8
    • 0032081365 scopus 로고    scopus 로고
    • Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images
    • Y. Sato, et al., "Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images," Med. Image Anal., vol. 2, pp. 143-168, 1998.
    • (1998) Med. Image Anal. , vol.2 , pp. 143-168
    • Sato, Y.1
  • 9
    • 61849147989 scopus 로고    scopus 로고
    • Multi-scale line segmentation with automatic estimation of width, contrast and tangential direction in 2D and 3D medical images
    • C. Lorenz, I. C. Carlsen, T. M. Buzug, C. Fassnacht, and J. Weese, "Multi-scale line segmentation with automatic estimation of width, contrast and tangential direction in 2D and 3D medical images," in Proc. CVRMed-MRCAS'97, 1997, pp. 233-242.
    • Proc. CVRMed-MRCAS'97, 1997 , pp. 233-242
    • Lorenz, C.1    Carlsen, I.C.2    Buzug, T.M.3    Fassnacht, C.4    Weese, J.5
  • 10
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • C. E. Metz, "Basic principles of ROC analysis," Seminars Nucl. Med., vol. 8, pp. 283-298, 1978.
    • (1978) Seminars Nucl. Med. , vol.8 , pp. 283-298
    • Metz, C.E.1
  • 11
    • 84934218772 scopus 로고
    • Display of surfaces from volume data
    • M. Levoy, "Display of surfaces from volume data," IEEE Comput. Graphics Applicat., vol. 8, pp. 29-37, 1988.
    • (1988) IEEE Comput. Graphics Applicat. , vol.8 , pp. 29-37
    • Levoy, M.1
  • 12
    • 0029810177 scopus 로고    scopus 로고
    • Virtual MR angioscopy of pulmonary artery tree
    • M. E. Ladd et al., "Virtual MR angioscopy of pulmonary artery tree," JCAT, vol. 20, pp. 782-785, 1996.
    • (1996) JCAT , vol.20 , pp. 782-785
    • Ladd, M.E.1
  • 13
    • 84947771236 scopus 로고    scopus 로고
    • Vascular shape segmentation and structure extraction using a shape-based region-growing model
    • Y. Masutani, T. Schiemann, and K. H. Hoehne, "Vascular shape segmentation and structure extraction using a shape-based region-growing model," in Proc. MICCAI '98, 1998, pp. 1242-1249.
    • Proc. MICCAI '98, 1998 , pp. 1242-1249
    • Masutani, Y.1    Schiemann, T.2    Hoehne, K.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.