-
1
-
-
0036064146
-
Minimally invasive fixation for unstable two-part proximal humeral fractures: Surgical techniques and clinical results using J-nails
-
Takeuchi R, et al: Minimally invasive fixation for unstable two-part proximal humeral fractures: Surgical techniques and clinical results using J-nails. J Orthop Trauma 16(6):403-408, 2002.
-
(2002)
J Orthop Trauma
, vol.16
, Issue.6
, pp. 403-408
-
-
Takeuchi, R.1
-
2
-
-
0035749814
-
Minimally invasive fracture stabilization of distal femoral fractures with the LISS: A prospective multicenter study: Results of a clinical study with special emphasis on difficult cases
-
Schutz M, et al: Minimally invasive fracture stabilization of distal femoral fractures with the LISS: A prospective multicenter study: Results of a clinical study with special emphasis on difficult cases. Injury 32(Suppl 3):SC48-54, 2001.
-
(2001)
Injury
, vol.32
, Issue.SUPPL. 3
-
-
Schutz, M.1
-
3
-
-
0035199340
-
A minimally invasive percutaneous technique of intramedullary nail insertion in an animal model of fracture healing
-
Bhandari M, Shaughnessy S: A minimally invasive percutaneous technique of intramedullary nail insertion in an animal model of fracture healing. Arch Orthop Trauma Surg 121(10):591-593, 2001.
-
(2001)
Arch Orthop Trauma Surg
, vol.121
, Issue.10
, pp. 591-593
-
-
Bhandari, M.1
Shaughnessy, S.2
-
4
-
-
0036291709
-
Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases
-
Apivatthakakul T, Arpornchayanon O: Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases. Injury 33(5):460-465, 2002.
-
(2002)
Injury
, vol.33
, Issue.5
, pp. 460-465
-
-
Apivatthakakul, T.1
Arpornchayanon, O.2
-
5
-
-
0031437267
-
Minimally invasive plate osteosynthesis and vascularity: Preliminary results of a cadaver injection study
-
Farouk O, et al: Minimally invasive plate osteosynthesis and vascularity: Preliminary results of a cadaver injection study. Injury 28(Suppl 1):A7-12, 1997.
-
(1997)
Injury
, vol.28
, Issue.SUPPL. 1
-
-
Farouk, O.1
-
6
-
-
0031452816
-
Minimally invasive plate osteosynthesis of distal fractures of the tibia
-
Helfet DL, et al: Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury 28(Suppl 1):A42-48, 1997.
-
(1997)
Injury
, vol.28
, Issue.SUPPL. 1
-
-
Helfet, D.L.1
-
7
-
-
0033173645
-
Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique?
-
Farouk O, et al: Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique? J Orthop Trauma 13(6):401-406, 1999.
-
(1999)
J Orthop Trauma
, vol.13
, Issue.6
, pp. 401-406
-
-
Farouk, O.1
-
8
-
-
0034826609
-
Minimally invasive reduction and osteosynthesis of articular fractures of the distal radius
-
Duncan SF, Weiland AJ: Minimally invasive reduction and osteosynthesis of articular fractures of the distal radius. Injury 32(Suppl 1):SA14-24, 2001.
-
(2001)
Injury
, vol.32
, Issue.SUPPL. 1
-
-
Duncan, S.F.1
Weiland, A.J.2
-
9
-
-
0344980123
-
Minimally invasive treatment of distal femur fractures: Report of a technique
-
Russell GV, Smith DG: Minimally invasive treatment of distal femur fractures: Report of a technique. J Trauma 47(4):799-801, 1999.
-
(1999)
J Trauma
, vol.47
, Issue.4
, pp. 799-801
-
-
Russell, G.V.1
Smith, D.G.2
-
10
-
-
0037006146
-
Minimally invasive treatment of osteoporotic vertebral body compression fractures
-
Garfin SR, Reilley MA: Minimally invasive treatment of osteoporotic vertebral body compression fractures. Spine J 2(1):76-80, 2002.
-
(2002)
Spine J
, vol.2
, Issue.1
, pp. 76-80
-
-
Garfin, S.R.1
Reilley, M.A.2
-
11
-
-
0030949054
-
New developments in stabilization of dia- and metaphyseal fractures of long tubular bones
-
Krettek C, Schandelmaier P, Tscherne H: [New developments in stabilization of dia- and metaphyseal fractures of long tubular bones]. Orthopade 26(5):408-421, 1997.
-
(1997)
Orthopade
, vol.26
, Issue.5
, pp. 408-421
-
-
Krettek, C.1
Schandelmaier, P.2
Tscherne, H.3
-
12
-
-
0344625394
-
New techniques in indirect reduction of long bone fractures
-
Ruedi TP, Sommer C, Leutenegger A: New techniques in indirect reduction of long bone fractures. Clin Orthop (347):27-34, 1998.
-
(1998)
Clin Orthop
, Issue.347
, pp. 27-34
-
-
Ruedi, T.P.1
Sommer, C.2
Leutenegger, A.3
-
14
-
-
0015963022
-
The normal circulation of bone and its response to surgical intervention
-
Rhinelander FW: The normal circulation of bone and its response to surgical intervention. J Biomed Mater Res 8(1):87-90, 1974.
-
(1974)
J Biomed Mater Res
, vol.8
, Issue.1
, pp. 87-90
-
-
Rhinelander, F.W.1
-
15
-
-
0016164585
-
Tibial blood supply in relation to fracture healing
-
Rhinelander FW: Tibial blood supply in relation to fracture healing. Clin Orthop 105:34-81, 1974.
-
(1974)
Clin Orthop
, vol.105
, pp. 34-81
-
-
Rhinelander, F.W.1
-
16
-
-
0035753023
-
Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur
-
Krettek C, Muller M, Miclau T: Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur. Injury 32(Suppl 3):SC14-23, 2001.
-
(2001)
Injury
, vol.32
, Issue.SUPPL. 3
-
-
Krettek, C.1
Muller, M.2
Miclau, T.3
-
17
-
-
0036854433
-
Evolution of the internal fixation of long bone fractures: The scientific basis of biological internal fixation: Choosing a new balance between stability and biology
-
Perren SM: Evolution of the internal fixation of long bone fractures: The scientific basis of biological internal fixation: Choosing a new balance between stability and biology. J Bone Joint Surg Br 84(8):1093-110, 2002.
-
(2002)
J Bone Joint Surg Br
, vol.84
, Issue.8
, pp. 1093-1110
-
-
Perren, S.M.1
-
18
-
-
0035749514
-
Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): The technique and early results
-
Kregor PJ, et al: Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): The technique and early results. Injury 32(Suppl 3):SC32-47, 2001.
-
(2001)
Injury
, vol.32
, Issue.SUPPL. 3
-
-
Kregor, P.J.1
-
19
-
-
0035749815
-
Distal femoral fractures and LISS stabilization
-
Schandelmaier P, et al: Distal femoral fractures and LISS stabilization. Injury 32(Suppl 3):SC55-63, 2001.
-
(2001)
Injury
, vol.32
, Issue.SUPPL. 3
-
-
Schandelmaier, P.1
-
20
-
-
17744404263
-
Less Invasive Stabilization System (LISS) for fractures of the proximal tibia: Indications, surgical technique and preliminary results of the UMC Clinical Trial
-
Cole PA, Zlowodzki M, Kregor PJ: Less Invasive Stabilization System (LISS) for fractures of the proximal tibia: Indications, surgical technique and preliminary results of the UMC Clinical Trial. Injury 34(Suppl 1):A16-29, 2003.
-
(2003)
Injury
, vol.34
, Issue.SUPPL. 1
-
-
Cole, P.A.1
Zlowodzki, M.2
Kregor, P.J.3
-
21
-
-
0038309765
-
Less Invasive Stabilization System (LISS) in the treatment of distal femoral fractures
-
Schutz M, et al: Less Invasive Stabilization System (LISS) in the treatment of distal femoral fractures. Acta Chir Orthop Traumatol Cech 70(2):74-82, 2003.
-
(2003)
Acta Chir Orthop Traumatol Cech
, vol.70
, Issue.2
, pp. 74-82
-
-
Schutz, M.1
-
22
-
-
0036298615
-
Percutaneous compression plating (PCCP) versus the dynamic hip screw for pertrochanteric hip fractures: Preliminary results
-
Brandt SE, et al: Percutaneous compression plating (PCCP) versus the dynamic hip screw for pertrochanteric hip fractures: Preliminary results. Injury 33(5):413-418, 2002.
-
(2002)
Injury
, vol.33
, Issue.5
, pp. 413-418
-
-
Brandt, S.E.1
-
23
-
-
0036626988
-
Percutaneous compression plating for intertrochanteric hip fractures: Treatment rationale
-
Gotfried Y: Percutaneous compression plating for intertrochanteric hip fractures: Treatment rationale. Orthopedics 25(6):647-652, 2002.
-
(2002)
Orthopedics
, vol.25
, Issue.6
, pp. 647-652
-
-
Gotfried, Y.1
-
24
-
-
0024547454
-
Subtrochanteric fractures of the femur: Results of treatment with the 95 degrees condylar blade-plate
-
Kinast C, et al: Subtrochanteric fractures of the femur: Results of treatment with the 95 degrees condylar blade-plate. Clin Orthop (238):122-130, 1989.
-
(1989)
Clin Orthop
, Issue.238
, pp. 122-130
-
-
Kinast, C.1
-
25
-
-
0035116129
-
Percutaneous plating of the low energy unstable tibial plateau fractures: A new technique
-
Kankate RK, Singh P, Elliott DS: Percutaneous plating of the low energy unstable tibial plateau fractures: A new technique. Injury 32(3):229-232, 2001.
-
(2001)
Injury
, vol.32
, Issue.3
, pp. 229-232
-
-
Kankate, R.K.1
Singh, P.2
Elliott, D.S.3
-
26
-
-
6044237628
-
Bridging external fixation for high energy proximal tibia fractures: Results of a prospective protocol
-
Salt Lake City, Utah
-
Egol KA, Capla EL, Wolinsky PL, Koval KJ: Bridging external fixation for high energy proximal tibia fractures: Results of a prospective protocol. Presented at the O.T.A annual meeting, 2003. Salt Lake City, Utah.
-
(2003)
O.T.A Annual Meeting
-
-
Egol, K.A.1
Capla, E.L.2
Wolinsky, P.L.3
Koval, K.J.4
-
27
-
-
0029658386
-
Percutaneous iliosacral screw fixation of vertical unstable pelvic ring fractures
-
Remiger A, Engelhardt P: [Percutaneous iliosacral screw fixation of vertical unstable pelvic ring fractures]. Swiss Surg 2(6):259-263, 1996.
-
(1996)
Swiss Surg
, vol.2
, Issue.6
, pp. 259-263
-
-
Remiger, A.1
Engelhardt, P.2
-
28
-
-
0028912061
-
Percutaneous iliosacral screw fixation: Early treatment for unstable posterior pelvic ring disruptions
-
Shuler TE, et al: Percutaneous iliosacral screw fixation: Early treatment for unstable posterior pelvic ring disruptions. J Trauma 38(3):453-458, 1995.
-
(1995)
J Trauma
, vol.38
, Issue.3
, pp. 453-458
-
-
Shuler, T.E.1
-
29
-
-
0031716042
-
Percutaneous iliosacral screw placement using image guided techniques
-
Tonetti J, et al: Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop (354):103-110, 1998.
-
(1998)
Clin Orthop
, Issue.354
, pp. 103-110
-
-
Tonetti, J.1
-
30
-
-
0029314802
-
Early results of percutaneous iliosacral screws placed with the patient in the supine position
-
Routt ML Jr, et al: Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207-214, 1995.
-
(1995)
J Orthop Trauma
, vol.9
, Issue.3
, pp. 207-214
-
-
Routt Jr., M.L.1
-
31
-
-
0029689344
-
Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: A cadaveric and clinical study
-
Routt ML Jr, et al: Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: A cadaveric and clinical study. J Orthop Trauma 10(3):171-177, 1996.
-
(1996)
J Orthop Trauma
, vol.10
, Issue.3
, pp. 171-177
-
-
Routt Jr., M.L.1
-
32
-
-
0031266643
-
Iliosacral screw fixation: Early complications of the percutaneous technique
-
Routt ML Jr, Simonian PT, Mills WJ: Iliosacral screw fixation: Early complications of the percutaneous technique. J Orthop Trauma 11(8):584-589, 1997.
-
(1997)
J Orthop Trauma
, vol.11
, Issue.8
, pp. 584-589
-
-
Routt Jr., M.L.1
Simonian, P.T.2
Mills, W.J.3
-
33
-
-
0142157071
-
Vertebroplasty and kyphoplasty for osteolytic vertebral collapse
-
Lieberman I, Reinhardt MK: Vertebroplasty and kyphoplasty for osteolytic vertebral collapse. Clin Orthop (415 Suppl):S176-186, 2003.
-
(2003)
Clin Orthop
, Issue.415 SUPPL.
-
-
Lieberman, I.1
Reinhardt, M.K.2
-
34
-
-
0010677426
-
Vertebroplasty: Techniques to avoid complications
-
Moreland DB, Landi MK, Grand W: Vertebroplasty: Techniques to avoid complications. Spine J 1(1):66-71, 2001.
-
(2001)
Spine J
, vol.1
, Issue.1
, pp. 66-71
-
-
Moreland, D.B.1
Landi, M.K.2
Grand, W.3
-
35
-
-
1442302381
-
Kyphoplasty and Vertebroplasty in fractures in the elderly. Effort and effect
-
Meeder PJ, et al: [Kyphoplasty and Vertebroplasty in fractures in the elderly. Effort and effect]. Chirurg 74(11):994-999, 2003.
-
(2003)
Chirurg
, vol.74
, Issue.11
, pp. 994-999
-
-
Meeder, P.J.1
|