Volumn 8, Issue 5, 2008, Pages 930-934

Detection of Legionella in hospital water supply using mip based primers

Author keywords

Hospitals water supplies; Legionella spp; Mip; PCR

Indexed keywords

BACTERIAL PROTEIN; HOT WATER; PROTEIN MIP; UNCLASSIFIED DRUG;

EID: 60249088848     PISSN: 17273048     EISSN: 18125719     Source Type: Journal    
DOI: 10.3923/jbs.2008.930.934     Document Type: Article
Times cited : (9)

References (23)
  • 1
    • 0026071369 scopus 로고
    • Detection of viable Legionella pneumophila in water by polymerase chain reaction and gene probe methods
    • Bej, A.K., M.H. Mahbubani and R.M. Atlas, 1991. Detection of viable Legionella pneumophila in water by polymerase chain reaction and gene probe methods. Applied Environ. Microbiol., 57 (2): 597-600.
    • (1991) Applied Environ. Microbiol , vol.57 , Issue.2 , pp. 597-600
    • Bej, A.K.1    Mahbubani, M.H.2    Atlas, R.M.3
  • 2
    • 0025195897 scopus 로고
    • Association of shower use with legionnaires' disease. Possible role of amoebae
    • Breiman, R.F., B.S. Fields and G. Sanden et al., 1990. Association of shower use with legionnaires' disease. Possible role of amoebae. JAMA., 263 (21): 2924-2926.
    • (1990) JAMA , vol.263 , Issue.21 , pp. 2924-2926
    • Breiman, R.F.1    Fields, B.S.2    Sanden, G.3
  • 3
    • 0024522755 scopus 로고
    • A Legionella pneumophila gene encoding a species- specific surface protein potentiates initiation of intracellular infection
    • Cianciotto, N.P., B.I. Eisenstein and C.H. Mody et al., 1989. A Legionella pneumophila gene encoding a species- specific surface protein potentiates initiation of intracellular infection. Infect. Immun., 57 (4): 1255-1262.
    • (1989) Infect. Immun , vol.57 , Issue.4 , pp. 1255-1262
    • Cianciotto, N.P.1    Eisenstein, B.I.2    Mody, C.H.3
  • 4
    • 9144268478 scopus 로고    scopus 로고
    • Risk and management in hospital water systems for Legionella pneumophila: A case study in Rio de Janerio- Brazil
    • Ferreira, A., 2004. Risk and management in hospital water systems for Legionella pneumophila: A case study in Rio de Janerio- Brazil. Int. J. Environ. Health Res., 14 (6): 453-459.
    • (2004) Int. J. Environ. Health Res , vol.14 , Issue.6 , pp. 453-459
    • Ferreira, A.1
  • 5
    • 33646460113 scopus 로고    scopus 로고
    • Detection of Legionella pneumophila serogroup 7 strain from bathwater samples in a Japanese hospital
    • Fujimura, S., T. Oka and O. Tooi et al., 2006. Detection of Legionella pneumophila serogroup 7 strain from bathwater samples in a Japanese hospital. J. Infect. Chemother., 12 (2): 105-108.
    • (2006) J. Infect. Chemother , vol.12 , Issue.2 , pp. 105-108
    • Fujimura, S.1    Oka, T.2    Tooi, O.3
  • 6
    • 39049145781 scopus 로고    scopus 로고
    • Persistence of Legionella in hospital water supplies and nosocomial legionnaires disease
    • Garcia-Nuñez, M., N. Sopena and S. Ragull et al., 2008. Persistence of Legionella in hospital water supplies and nosocomial legionnaires disease. FEMS. Immunol. Med. Microbiol., 52 (2): 202-206.
    • (2008) FEMS. Immunol. Med. Microbiol , vol.52 , Issue.2 , pp. 202-206
    • Garcia-Nuñez, M.1    Sopena, N.2    Ragull, S.3
  • 7
    • 60249090849 scopus 로고    scopus 로고
    • Hosseini Doust, S.R. and D. Seal, 1998. Isolation of legionnaire's disease bacterium from hospital water supplies. Kowsar. Med. J., 3 (3): 145-150.
    • Hosseini Doust, S.R. and D. Seal, 1998. Isolation of legionnaire's disease bacterium from hospital water supplies. Kowsar. Med. J., 3 (3): 145-150.
  • 8
    • 0031864376 scopus 로고    scopus 로고
    • Comparison of sample preparation methods for detection of Legionella pneumophila in culture positive bronchoalveolar lavage fluids by PCR
    • Jaulhac, B., M. Reyrolle and Y.K. Sodahlon et al., 1998. Comparison of sample preparation methods for detection of Legionella pneumophila in culture positive bronchoalveolar lavage fluids by PCR. J. Clin Microbiol., 36 (7): 2120-2122.
    • (1998) J. Clin Microbiol , vol.36 , Issue.7 , pp. 2120-2122
    • Jaulhac, B.1    Reyrolle, M.2    Sodahlon, Y.K.3
  • 9
    • 13344281029 scopus 로고    scopus 로고
    • Outbreak of legionnaire's disease among cruise ship passengers exposed to a contaminated whirlpool spa
    • Jernigan, D.B., J. Hofman and M.S. Cetron, 1996. Outbreak of legionnaire's disease among cruise ship passengers exposed to a contaminated whirlpool spa. Lancet 347 (9000): 494-499.
    • (1996) Lancet , vol.347 , Issue.9000 , pp. 494-499
    • Jernigan, D.B.1    Hofman, J.2    Cetron, M.S.3
  • 10
    • 0029671078 scopus 로고    scopus 로고
    • Keller, D.W., R. Hajjeh and A. DeMaria, 1996. Community outbreak of legionnaire's disease: An investigation confirming the potential for cooling towers to transmit Legionella species. Clmi. Infect. Dis., 22 (2): 257-261.
    • Keller, D.W., R. Hajjeh and A. DeMaria, 1996. Community outbreak of legionnaire's disease: An investigation confirming the potential for cooling towers to transmit Legionella species. Clmi. Infect. Dis., 22 (2): 257-261.
  • 11
    • 0033255498 scopus 로고    scopus 로고
    • Hospital characteristics associated with colonization of water system by Legionella and risk of nosocomial legionnaires' disease
    • Kool, J.L., D. Bergmire-Sweet and J.C. Butler, 1999. Hospital characteristics associated with colonization of water system by Legionella and risk of nosocomial legionnaires' disease. Infect Control. Hosp. Epidemiol., 20 (12): 798-805.
    • (1999) Infect Control. Hosp. Epidemiol , vol.20 , Issue.12 , pp. 798-805
    • Kool, J.L.1    Bergmire-Sweet, D.2    Butler, J.C.3
  • 12
    • 0345355209 scopus 로고    scopus 로고
    • Detecting legionellosis by unselected culture of respiratory tract secretions and developing links to hospital water strains
    • Kooler, J.R., M. Maidwald and P.C. Luck et al., 1999. Detecting legionellosis by unselected culture of respiratory tract secretions and developing links to hospital water strains. J. Hosp. Infect., 41 (4): 301-311.
    • (1999) J. Hosp. Infect , vol.41 , Issue.4 , pp. 301-311
    • Kooler, J.R.1    Maidwald, M.2    Luck, P.C.3
  • 13
    • 0032767434 scopus 로고    scopus 로고
    • Single clonal origin of a high proportion of L. pneumophila serogroup 1 isolates from patients and environment in the area of Paris, France, over a 10 year period
    • Lawrence, C., M. Reyroll and Dubrou et al., 1999. Single clonal origin of a high proportion of L. pneumophila serogroup 1 isolates from patients and environment in the area of Paris, France, over a 10 year period. J. Clin. Microbiol., 37 (18): 2652-2655.
    • (1999) J. Clin. Microbiol , vol.37 , Issue.18 , pp. 2652-2655
    • Lawrence, C.1    Reyroll, M.2    Dubrou3
  • 14
    • 30844441624 scopus 로고    scopus 로고
    • Legionaires disease: A nosocomial out break in Turkey
    • Ozerol, I.H., M. Bayraktar and Z. Cizmeci et al., 2006. Legionaires disease: A nosocomial out break in Turkey. J. Hosp. Infect. 62 (1): 50-57.
    • (2006) J. Hosp. Infect , vol.62 , Issue.1 , pp. 50-57
    • Ozerol, I.H.1    Bayraktar, M.2    Cizmeci, Z.3
  • 15
    • 0027872611 scopus 로고
    • Detection of Legionella species in sewage and ocean water by polymerase cham reaction, direct fluorescent-antibody and culture methods
    • Palmer, C.J., Y. Litsai and C. Paszko-Kolva et al., 1993. Detection of Legionella species in sewage and ocean water by polymerase cham reaction, direct fluorescent-antibody and culture methods. Applied Environ. Microbiol., 59 (11): 3618-3624.
    • (1993) Applied Environ. Microbiol , vol.59 , Issue.11 , pp. 3618-3624
    • Palmer, C.J.1    Litsai, Y.2    Paszko-Kolva, C.3
  • 16
    • 0030880260 scopus 로고    scopus 로고
    • Colonization of transplant unit water supplies with Legionella and protozoa
    • Patterson, W.G., J. Hay and D.V. Seal et al., 1997. Colonization of transplant unit water supplies with Legionella and protozoa. J. Hosp. Infect., 37 (1): 7-17.
    • (1997) J. Hosp. Infect , vol.37 , Issue.1 , pp. 7-17
    • Patterson, W.G.1    Hay, J.2    Seal, D.V.3
  • 17
    • 36448950507 scopus 로고    scopus 로고
    • Isolation of Legionella species/serogroups from water cooling systems compared with potable water systems in Spanish healthcare facilities
    • Rivera, J.M., L. Aguilar and J.J. Granizo et al., 2007. Isolation of Legionella species/serogroups from water cooling systems compared with potable water systems in Spanish healthcare facilities. J. Hosp. Infect., 67 (4): 360-366.
    • (2007) J. Hosp. Infect , vol.67 , Issue.4 , pp. 360-366
    • Rivera, J.M.1    Aguilar, L.2    Granizo, J.J.3
  • 18
    • 27144485188 scopus 로고    scopus 로고
    • Singh, T. and M.M. Coogan, 2005. Isolation of pathogenic Legionella species and Legionella-laden amoebae in dental unit waterlines.. J. Hosp. Infect., 61 (3): 2S7-262.
    • Singh, T. and M.M. Coogan, 2005. Isolation of pathogenic Legionella species and Legionella-laden amoebae in dental unit waterlines.. J. Hosp. Infect., 61 (3): 2S7-262.
  • 19
    • 0021931907 scopus 로고
    • Ecology of L. pneumophila within water distribution systems
    • Stout J.E., V.L. Yu and M.G. Best, 1985. Ecology of L. pneumophila within water distribution systems. Applied Environ. Microbiol., 49 (1): 221-228.
    • (1985) Applied Environ. Microbiol , vol.49 , Issue.1 , pp. 221-228
    • Stout, J.E.1    Yu, V.L.2    Best, M.G.3
  • 20
    • 0032450212 scopus 로고    scopus 로고
    • Epidemiology of Legionella pneumonia and factors associated with Legionella related mortality at a tertiary care center
    • Tkatch, L.S, S. Kusune and W.D. Irish et al., 1998. Epidemiology of Legionella pneumonia and factors associated with Legionella related mortality at a tertiary care center. Clin. Infect. Dis., 27 (6): 1479-1486.
    • (1998) Clin. Infect. Dis , vol.27 , Issue.6 , pp. 1479-1486
    • Tkatch, L.S.1    Kusune, S.2    Irish, W.D.3
  • 21
    • 36249006117 scopus 로고    scopus 로고
    • Legionella contamination in the water system of hospital dental settings
    • Veronesi, L., E. Capobianco and P. Affanni et al., 2007. Legionella contamination in the water system of hospital dental settings. Acta Biomed., 78 (2): 117-122.
    • (2007) Acta Biomed , vol.78 , Issue.2 , pp. 117-122
    • Veronesi, L.1    Capobianco, E.2    Affanni, P.3
  • 22
    • 0026463026 scopus 로고
    • Transmission of Legionella by respiratory equipment aerosol generating devices
    • Woo, A.H., A. Cioetz and V.L. Yu, 1992. Transmission of Legionella by respiratory equipment aerosol generating devices. Chest, 102 (5): 1586-1590.
    • (1992) Chest , vol.102 , Issue.5 , pp. 1586-1590
    • Woo, A.H.1    Cioetz, A.2    Yu, V.L.3
  • 23
    • 0033845771 scopus 로고    scopus 로고
    • Nosocomial legionellosis
    • Yu, V.L., 2000. Nosocomial legionellosis. Curr. Opin. Infect. Dis., 13 (4): 385-388.
    • (2000) Curr. Opin. Infect. Dis , vol.13 , Issue.4 , pp. 385-388
    • Yu, V.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.